D100E Datasheet - Micropower Direct

D100E Series
Low Cost, 1W SIP
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
Parameter
Conditions
• 1W Output Power
• Miniature SIP Case
• UL Approved (File E245422)
Input Voltage Range
• Single & Dual Outputs
Input Filter
Reverse Polarity Input Current
• 1,000 VDC Isolation
Output
• >3.5 MHour MTBF
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefficient
Output Short Circuit
• 24 Standard Models
• LOWEST COST!!
Min.
Typ.
5 VDC Input
4.5
5.0
12 VDC Input 10.8
12.0
24 VDC Input 21.6
24.0
Internal Capacitor
Conditions
Min.
Typ.
±1.0
Dual Output , Balanced Loads
±0.1
For Vin Change of 1%
±1.2
See Model Selection Guide
See Note 2
50
120
±0.02
Momentary (1.0 Sec.)
Max.
5.5
13.2
26.4
Units
0.3
A
Max.
±3.0
±1.0
Units
%
%
%
75
mV P - P
%
%/ºC
±0.03
VDC
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
1,000
Typ.
Max.
Units
VDC
M
pF
kHz
Max.
+85
+125
Units
ºC
ºC
95
%
60
100
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
0.77 x 0.24 x 0.40 Inches (19.6 x 6.0 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.07 Oz (2.1g)
Reliability Specifications
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
MTBF
Safety Standards
Safety Approvals
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
Typ.
Max.
Units
3.5
MHours
UL 1950, EN 60950, IEC 60950
UL, cUL; File No. E245422
Absolute Maximum Ratings
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
30.0
300
450
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Units
VDC
ºC
mW
www.micropowerdirect.com
Model Selection Guide
Model
Number
D101E
D102E
D103E
D104E
D105E
D106E
D107E
D108E
D111E
D112E
D113E
D114E
D115E
D116E
D117E
D118E
D121E
D122E
D123E
D124E
D125E
D126E
D127E
D128E
Input
Voltage (VDC)
Current (mA)
Voltage
Nominal
Range
Full-Load No-Load (VDC)
5
4.5 - 5.5
278
30
5.0
5
4.5 - 5.5
270
30
9.0
5
4.5 - 5.5
260
30
12.0
5
4.5 - 5.5
253
30
15.0
5
4.5 - 5.5
278
30
±5.0
5
4.5 - 5.5
267
30
±9.0
5
4.5 - 5.5
256
30
±12.0
5
4.5 - 5.5
253
30
±15.0
12
10.8 - 13.2
114
15
5.0
12
10.8 - 13.2
111
15
9.0
12
10.8 - 13.2
105
15
12.0
12
10.8 - 13.2
104
15
15.0
12
10.8 - 13.2
113
15
±5.0
12
10.8 - 13.2
110
15
±9.0
12
10.8 - 13.2
105
15
±12.0
12
10.8 - 13.2
104
15
±15.0
24
21.6 - 26.4
56
8
5.0
24
21.6 - 26.4
55
8
9.0
24
21.6 - 26.4
52
8
12.0
24
21.6 - 26.4
51
8
15.0
24
21.6 - 26.4
56
8
±5.0
24
21.6 - 26.4
55
8
±9.0
24
21.6 - 26.4
52
8
±12.0
24
21.6 - 26.4
51
8
±15.0
Output
Current
Current
Load
Regulation
(mA, Max)
(mA, Min)
(%, Max)
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
20.0
12.0
9.0
7.0
±10.0
±6.0
±5.0
±4.0
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
200.0
111.0
83.0
67.0
±100.0
±56.0
±42.0
±33.0
200.0
111.0
83.0
67.0
±100.0
±56.0
±42.0
±33.0
200.0
111.0
83.0
67.0
±100.0
±56.0
±42.0
±33.0
Rating
Efficiency Fuse
Slow-Blow
(%, Typ)
(mA)
72
74
77
79
72
75
78
79
73
75
79
80
74
76
79
80
74
76
80
81
74
76
80
81
500
500
500
500
500
500
500
500
200
200
200
200
200
200
200
200
100
100
100
100
100
100
100
100
Derating Curve
Other input/output combinations are available
(i.e. 3.3 VDC). Contact the factory for details at:
[email protected]
Notes:
1. Output load regulation is specified for a load change of 10% to 100%.
2. These units should not be operated with a load under 10% of full load. Operation at noload may cause damage to the unit.
3. These converters will operate without external components. However, when measuring
output ripple, it is recommended that an external ceramic capacitor be placed from the
+Vout pin to the -Vout pin for single output units and from each output to common for dual
output units. An input
Output Capacitor
Input
capacitor will enhance
Vin
Vout
Capacitor
stability over temperature
Single Dual
and input line variations. 5 VDC
4.7 µF 5 VDC 10.0 µF 4.7 µF
Recommended capacitor
9 VDC 4.7 µF 2.2 µF
values are given in the 12 VDC 2.2 µF
table above. For applica- 24 VDC 1.0 µF 12 VDC 2.2 µF 1.0 µF
tions requiring very low
15 VDC 1.0 µF 0.47 µF
output noise levels, a
simple LC filter should be effective.
4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output. To do
this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float
the output common
5. It is recommended that a fuse be used on the input of a power supply for protection. See
the Model Selection table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
Pin
Single
Dual
1
2
4
+Vin
-Vin
-Vout
+Vin
-Vin
-Vout
5
6
No Pin
+Vout
Common
+Vout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the side of the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]