A400RU Series Single & Dual Output, 4W Ultra-Wide Input Range DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 4W Output Power Input Parameter • EN 60950 Approved (UL) Input Start Voltage • 4:1 Input Voltage Range Input Filter Reverse Polarity Input Current Short Circuit Input Power Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time, See Note 2 Transient Response Deviation Temperature Coefficient Output Short Circuit General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Environmental Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity RFI Conducted EMI Physical Case Size Case Material Weight Reliability Specifications Parameter MTBF Safety Standards Safety Approvals Absolute Maximum Ratings Parameter • 1,500 VDC Isolation • Meets EN55022 Class “A” • Compact DIP Case • Single & Dual Outputs • 1.0 MH MTBF • Industry Standard Pin-Out MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Conditions Min. Typ. Max. 24 VDC Input 4.5 6.0 8.5 48 VDC Input 8.5 12.0 17.0 (Pi) Filter (Complies with EN55022 Class “A”) 1.0 2,000 Conditions Min. Dual Output , Balanced Loads Vin = Min to Max Iout = 10% to 100% See Note 1 Over Line, Load & Temp. Typ. ±0.5 ±0.5 ±0.1 ±0.3 50 Max. ±1.0 ±2.0 ±0.3 ±1.0 75 100 15 120 150 ±2.0 ±0.01 Continuous (Autorecovery) 25% Load Step Change Conditions 60 Seconds 500 VDC 100 kHz, 1V Min. 1,500 1,000 500 ±0.02 Typ. Max. 380 350 500 Conditions Min. Typ. -40 +25 -40 -40 Free Air Convection RH, Non-condensing Six-Side Shielded Metal Case Complies with EN55022 Class “A” Ambient Case Units VDC A mW Units % % % % mV P - P mV P - P mV rms % µSec % %/ºC Units VDC M pF kHz Max. +71 +90 +125 Units ºC ºC ºC 95 % 1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm) Metal with Non-Conductive Base 0.49 Oz (14g) Conditions Min. Typ. MIL HDBK 217F, 25ºC, Gnd Benign 1.0 UL 60950, EN 60950 UL, cUL; File No. E245422 Conditions 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec. All Models Min. -0.7 -0.7 Typ. Max. Units MHours Max. 50.0 100.0 260 2,500 Units Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC ºC mW www.micropowerdirect.com Model Selection Guide Input Model Number A401RU A402RU A403RU A404RU A405RU A406RU A407RU A411RU A412RU A413RU A414RU A415RU A416RU A417RU Voltage (VDC) Current (mA) Nominal Range 24 24 24 24 24 24 24 48 48 48 48 48 48 48 9.0 -36.0 9.0 -36.0 9.0 -36.0 9.0 -36.0 9.0 -36.0 9.0 -36.0 9.0 -36.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 18.0 - 75.0 Full-Load No-Load 161 170 201 201 156 201 201 79 84 98 98 76 98 98 Reflected Ripple Current Voltage (mA, Typ) (VDC) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±5.0 ±12.0 ±15.0 20 20 20 20 20 20 20 10 10 10 10 10 10 10 Notes: 1. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For 24V input units a 4.7 µF is recommended and for 48V units a 2.2 µF. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Pin Connections Pin Single Dual 2, 3 -Vin -Vin 9 No Pin Common 11 NC -Vout 14 +Vout +Vout 16 -Vout Common 22, 23 +Vin +Vin Output Current Current (mA, Max) (mA, Min) 900.0 660.0 333.0 267.0 ±300.0 ±167.0 ±133.0 900.0 660.0 333.0 267.0 ±300.0 ±167.0 ±133.0 90.0 66.0 33.0 27.0 ±30.0 ±17.0 ±13.0 90.0 66.0 33.0 27.0 ±30.0 ±17.0 ±13.0 Rating Efficiency Fuse Slow-Blow (%, Typ) (mA) 77 81 83 83 80 83 83 78 82 85 85 82 85 85 1,000 1,000 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 500 500 Derating Curve Mechanical Dimensions NC: No Connection Capacitive Load Single Output µF Max Dual Output µF Max 3,000 ±680 Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]