A400RU Datasheet

A400RU Series
Single & Dual Output, 4W
Ultra-Wide Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 4W Output Power
Input
Parameter
• EN 60950 Approved (UL)
Input Start Voltage
• 4:1 Input Voltage Range
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
RFI
Conducted EMI
Physical
Case Size
Case Material
Weight
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Approvals
Absolute Maximum Ratings
Parameter
• 1,500 VDC Isolation
• Meets EN55022 Class “A”
• Compact DIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
• Industry Standard Pin-Out
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
Conditions
Min.
Typ.
Max.
24 VDC Input
4.5
6.0
8.5
48 VDC Input
8.5
12.0
17.0
␲ (Pi) Filter (Complies with EN55022 Class “A”)
1.0
2,000
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 10% to 100%
See Note 1
Over Line, Load & Temp.
Typ.
±0.5
±0.5
±0.1
±0.3
50
Max.
±1.0
±2.0
±0.3
±1.0
75
100
15
120
150
±2.0
±0.01
Continuous (Autorecovery)
25% Load Step Change
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
500
±0.02
Typ.
Max.
380
350
500
Conditions
Min.
Typ.
-40
+25
-40
-40
Free Air Convection
RH, Non-condensing
Six-Side Shielded Metal Case
Complies with EN55022 Class “A”
Ambient
Case
Units
VDC
A
mW
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
µSec
%
%/ºC
Units
VDC
M
pF
kHz
Max.
+71
+90
+125
Units
ºC
ºC
ºC
95
%
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Metal with Non-Conductive Base
0.49 Oz (14g)
Conditions
Min.
Typ.
MIL HDBK 217F, 25ºC, Gnd Benign
1.0
UL 60950, EN 60950
UL, cUL; File No. E245422
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec.
All Models
Min.
-0.7
-0.7
Typ.
Max.
Units
MHours
Max.
50.0
100.0
260
2,500
Units
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
mW
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
A401RU
A402RU
A403RU
A404RU
A405RU
A406RU
A407RU
A411RU
A412RU
A413RU
A414RU
A415RU
A416RU
A417RU
Voltage (VDC)
Current (mA)
Nominal
Range
24
24
24
24
24
24
24
48
48
48
48
48
48
48
9.0 -36.0
9.0 -36.0
9.0 -36.0
9.0 -36.0
9.0 -36.0
9.0 -36.0
9.0 -36.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
18.0 - 75.0
Full-Load No-Load
161
170
201
201
156
201
201
79
84
98
98
76
98
98
Reflected
Ripple
Current Voltage
(mA, Typ)
(VDC)
5
5
5
5
5
5
5
5
5
5
5
5
5
5
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
20
20
20
20
20
20
20
10
10
10
10
10
10
10
Notes:
1. When measuring output ripple, it is recommended that an external 0.47 µF ceramic
capacitor be placed from the +Vout pin to the -Vout pin for single output units and
from each output to common for dual output units. For noise sensitive applications,
the use of 3.3 µF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a load step change
of 75% to 100%.
3. Operation at no-load will not damage these units. However, they may not meet all
specifications.
4. Dual output units may be connected to provide a 10 VDC,
24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout)
and negative (-Vout) outputs and float the output common.
5. The converter should be connected to a low ac-impedance source. An input source
with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied
over long lines, it may be necessary to use a capacitor on the input to insure
start-up.
In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor
be mounted close to the converter. For 24V input units a 4.7 µF is recommended
and for 48V units a 2.2 µF.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Pin Connections
Pin
Single
Dual
2, 3
-Vin
-Vin
9
No Pin
Common
11
NC
-Vout
14
+Vout
+Vout
16
-Vout
Common
22, 23
+Vin
+Vin
Output
Current
Current
(mA, Max)
(mA, Min)
900.0
660.0
333.0
267.0
±300.0
±167.0
±133.0
900.0
660.0
333.0
267.0
±300.0
±167.0
±133.0
90.0
66.0
33.0
27.0
±30.0
±17.0
±13.0
90.0
66.0
33.0
27.0
±30.0
±17.0
±13.0
Rating
Efficiency Fuse
Slow-Blow
(%, Typ)
(mA)
77
81
83
83
80
83
83
78
82
85
85
82
85
85
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
Derating Curve
Mechanical Dimensions
NC: No Connection
Capacitive Load
Single Output
µF Max
Dual Output
µF Max
3,000
±680
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]