A200RHI Datasheet - Micropower Direct

A200RHI Series
Very High Isolation, 2W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 2W Output Power
• 8,000 VDC Isolation
• 2 µA Leakage Current Max
• Compact DIP Case
• Single & Dual Outputs
• Meets EN55022 Class A
• 600 kH MTBF
• Industry Standard Pin-Out
Input
Parameter
Conditions
Input Voltage Range
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Min.
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input 10.8
12.0
13.2
24 VDC Input 21.6
24.0
26.4
␲ (Pi) Filter (Complies with EN55022 Class A)
0.5
2,000
Units
VDC
A
mW
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 10% to 100%
See Note 1
Over Line, Load & Temp.
Typ.
±2.0
±2.0
±0.3
±0.5
30
Max.
±4.0
±4.0
±0.5
±1.0
50
100
5
120
±0.01
50
±6.0
±0.02
Typ.
Max.
50% Load Step Change
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
µSec
%
%/ºC
Continuous
General
Parameter
Isolation Voltage, Rated
Isolation Test Voltage
Leakage Current
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
Flash Tested For 1 Second
240 VAC, 60 Hz
500 VDC
100 kHz, 1V
Min.
6,000
8,000
20
30
80
Units
VDC
VDC
µA
G⍀
pF
kHz
Typ.
Max.
+60
+90
+125
Units
ºC
ºC
ºC
95
%
2
10
25
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-25
-40
Free Air Convection
RH, Non-condensing
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.42 Oz (12g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
600
Typ.
Max.
Units
kHours
Min.
-0.7
-0.7
-0.7
Typ.
Max.
7.5
15.0
30.0
260
2,000
Units
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
All Models
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
mW
www.micropowerdirect.com
Model Selection Guide
Model
Number
Voltage (VDC)
Nominal
Range
Input
Current (mA)
Output
Reflected
Ripple Voltage
(VDC)
Full-Load No-Load Current
Current
Current
(mA, Max)
(mA, Min)
400
165
133
±100
±83
±66
400
165
133
±100
±83
±66
400
165
133
±100
±83
±66
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
Rating
Efficiency Fuse
Slow-Blow
(%, Typ)
(mA)
(mA, Typ)
A201RHI
A202RHI
A203RHI
A204RHI
A205RHI
A206RHI
A211RHI
A212RHI
A213RHI
A214RHI
A215RHI
A216RHI
A221RHI
A222RHI
A223RHI
A224RHI
A225RHI
A226RHI
5
5
5
5
5
5
12
12
12
12
12
12
24
24
24
24
24
24
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
4.5 - 5.5
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
10.8 - 13.2
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
21.6 - 26.4
645
629
623
476
699
695
269
262
260
185
281
280
134
131
130
93
143
142
100
100
100
100
100
100
50
50
50
50
50
50
30
30
30
30
30
30
15
15
15
15
15
15
8
8
8
8
8
8
3
3
3
3
3
3
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0
12.0
15.0
±5.0
±12.0
±15.0
5.0
12.0
15.0
±5.0
±12.0
±15.0
Notes:
1. When measuring output ripple, it is recommended that an external 0.33 µF ceramic
capacitor be placed from the +Vout pin to the -Vout pin for single output units and
from each output to common for dual output units. For noise sensitive applications,
the use of 1.5 µF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a load step change of
50% to 100%.
3. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output.
To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs
and float the output common.
4. The converter should be connected to a low ac-impedance source. An input source
with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long
lines, it may be necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be
mounted close to the converter. For 5V input units a 4.7µF is recommended, and for
12V & 24V units a 2.2 µF.
5. It is recommended that a fuse be used on the input of a power supply for protection.
See the table above for the correct rating.
62
63
64
42
57
57
62
63
64
45
59
59
62
63
64
45
58
58
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
250
250
250
250
250
250
Derating Curve
Capacitive Load
Single Output Dual Output
(µF Max)
(µF Max)
470
Mechanical Dimensions
±220
Pin Connections
Pin
Single
Dual
1, 2
+Vin
+Vin
10, 11
No Pin
Common
12
-Vout
No Pin
13
+Vout
-Vout
15
No Pin
+Vout
23, 24
-Vin
-Vin
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]