MA300SERU Datasheet

MA300ERU Series
Wide 4:1 Input, 3W
Single Output DIP
DC/DC Converters
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 3W Output Power
Input
Parameter
• 4:1 Input Voltage Range
Input Voltage Range
• 1,500 VDC Isolation
Input Start Voltage
• 12 Standard Models
• Efficiency to 83%
• Compact DIP Case
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Low Cost
Conditions
Min.
24 VDC Input
9.0
48 VDC Input 18.0
24 VDC Input
4.5
48 VDC Input 11.0
(Pi) Filter
Input Filter
No Load Input Power
Typ.
24.0
48.0
7.0
16.0
Max.
36.0
75.0
9.0
18.0
Units
0.2
0.5
W
Typ.
±1.0
±1.5
±0.2
±0.2
30
35
0.5
±2.0
±0.02
Max.
±3.0
±5.0
±0.5
±1.0
45
85
3.0
±5.0
±0.03
Units
%
%
%
%
VDC
VDC
Output
Parameter
Output Voltage Accuracy
No Load Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple (20 MHz)
Noise (20 MHz)
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Over Voltage Protection
Output Short Circuit, See Note 3
Conditions
IOUT = 5% to 100%
VIN = Min to Max
VIN = Min to Max
IOUT = 5% to 100%
Min.
See Note 1
25% Load Step Change
110
Continuous (Autorecovery)
mV P - P
mSec
%
%/°C
%
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Voltage Dips
Conditions
60 Seconds
500 VDC
100 kHz/0.1V
Min.
1,500
1,000
Typ.
Max.
120
250
Standard
See Note 4
EN 55022
See Note 4
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 5
EN 61000-4-4
See Note 6
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
Units
VDC
M
pF
kHz
Level
Class A
Class A
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
Max.
+85
+125
Units
°C
°C
95
%
See Mechanical Diagram (Page 4)
Aluminum Alloy
0.49 Oz (15g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
300
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
Voltage (VDC)
Nominal
Range
Output
Current (mA)
Voltage
Full-Load No-Load (VDC)
Current
Current
(mA, Max)
(mA, Min)
Efficiency
(%, Typ)
Fuse
Reflected Capacitive
Ripple
Rating
Load
Current
Slow-Blow
(µF, Max)
(mA Typ)
(mA)
MA324S-03ERU
24
9.0 - 36.0
166
10
3.3
909
45
75
30.0
2,700
300
MA324S-05ERU
24
9.0 - 36.0
156
10
5.0
600
30
80
30.0
2,200
300
MA324S-09ERU
24
9.0 - 36.0
156
10
12.0
333
17
80
30.0
1,000
300
MA324S-12ERU
24
9.0 - 36.0
154
10
12.0
250
13
81
30.0
680
300
MA324S-15ERU
24
9.0 - 36.0
152
10
15.0
200
10
82
30.0
680
300
MA324S-24ERU
24
9.0 - 36.0
152
10
24.0
125
6
82
30.0
470
300
MA348S-03ERU
48
18.0 - 75.0
82
8
12.0
909
45
76
30.0
2,700
150
MA348S-05ERU
48
18.0 - 75.0
79
8
5.0
600
30
79
30.0
2,200
150
MA348S-09ERU
48
18.0 - 75.0
77
8
12.0
333
17
81
30.0
1,000
150
MA348S-12ERU
48
18.0 - 75.0
76
8
12.0
250
13
82
30.0
680
150
MA348S-15ERU
48
18.0 - 75.0
75
8
15.0
200
10
83
30.0
680
150
MA348S-24ERU
48
18.0 - 75.0
77
8
24.0
125
6
81
30.0
470
150
Notes:
1. When measuring output ripple & noise, it is recommended that an external capacitor
(1 µF to 10 µF) be placed from the +VOUT to the -VOUT pins.
2. Transient recovery is measured to within a 1% error band for a load step change
of 25%.
3. Short circuit protection is provided by a “hiccup mode” circuit.
4. All units are rated for EN 55022 (CE/RE) class A without external components. They
will meet class B with the addition of the discrete filter circuit as shown on page 3.
Contact the factory for more information.
5. To meet the requirements of EN 61000-4-4 (±2 kV), external components are
needed, as shown on page 3. Contact the factory for more information.
6. To meet the requirements of EN 61000-4-5 (±2 kV), external components are
needed. This can be done discretely as shown on page 3. Contact the factory for
more information.
7. These units should not be operated with a load under 5% of full load. Operation
at no-load will not damage the unit, but they may not meet all specifications.
8. It is recommended that a fuse be used on the input of a power supply for protection.
See the Model Selection table above for the correct rating.
Efficiency vs Input Voltage 24 VDC Input
Efficiency vs Input Voltage 48 VDC Input
Efficiency vs Output Load 24 VDC Input
Efficiency vs Output Load 48 VDC Input
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
The diagram below illustrates a typical connection of the MA300SERU series for
applications that require meeting EMC standards. The units do not require external
components to operate as specified. Some notes on this diagram (starting with the
input circuit) are:
1. It is recommended that an external fuse be used. The recommended fuse is shown
in the model chart on page 2.
2. An external MOV is recommended on the input to protect the unit in the event of
a surge. A recommended value is given in the table at below.
3. The output filtering capacitor (C4) is a low ESR electrolytic capacitor. Care must be
taken in choosing this capacitor not to exceed the capacitive load specification for
the unit. Voltage derating of capacitors should be 80% or above.
4. Recommended values for components are:
Component
MOV
C1
C2
LDM1
C3
CY1
C4
24 VIN
S14K35
330 µF/50V
4.7 µF/50V
12 µH
4.7 µF/50V
1.0 nF/2 kV
10 µF
www.micropowerdirect.com
Derating Curve
48 VIN
S14K60
330 µF/100V
4.7 µF/100V
12 µH
4.7 µF/100V
1.0 nF/2 kV
10 µF
5. The “Typical Board Layout” drawing shows a suggested board layout for the EMC/
EMI circuit. Filtering capacitor (C4) is a low ESR resistance electrolytic capacitor.
Care must be taken in choosing this capacitor not to exceed the capacitive load
specification for the unit.
6. In many applications simply adding input/output capacitors will enhance
the input surge protection and reduce output ripple sufficiently. Typically,
the value of the input capacitor should be 10 µF to 47 µF. The recommended output capacitor would be 10 µF. A typical board layout for this
connection is shown at the bottom of this page.
Typical Connection
Typical Board Layout: With External Filter/Surge Components
Typical Board Layout: With External Input/Output Capacitors
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions
Pin Connections
Pin
2
3
11
14
16
22
23
Single Output
-Vin
-Vin
No Connection
+Vout
-Vout
+Vin
+Vin
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
Packing Tube Dimensions
Notes:
•
•
•
•
Tube length equals 20.866 (530), unit quantity equals 15 pcs.
Tube length equals 8.661 (220), unit quantity equals 6 pcs.
All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.02 (±0.50)