B1500RW Series Compact 1 x 2 Inch 15W Wide Input Range DC/DC Con verters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input Key Features: • 15W Output Power • 2:1 Input Voltage Range • 1,500 VDC Isolation • Compact 1 x 2 Inch Case • Single & Dual Outputs • Optional Remote ON/OFF • Industry Standard Pin-Out Parameter Input Start Voltage Input Filter Reverse Polarity Input Current Short Circuit Input Power Conditions Min. Typ. Max. 12 VDC Input 8.6 8.8 9.0 24 VDC Input 15.0 17.0 18.0 48 VDC Input 30.0 33.0 36.0 (Pi) Filter (Complies with EN55022 Class “A”) 1.0 3,500 Units VDC A mW Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit Conditions Min. Typ. ±1.0 ±0.5 ±0.1 ±0.1 55 Max. ±2.0 ±2.0 ±0.5 ±1.0 80 100 15 300 ±2.0 ±0.01 Continuous (Autorecovery) 500 ±4.0 ±0.02 Dual Output , Balanced Loads Vin = Min to Max Iout = 10% to 100% Over Line, Load & Temp. 120 25% Load Step Change Units % % % % mV P - P mV P - P mV rms % µSec % %/°C General Parameter Isolation Voltage Isolation Test Voltage Isolation Resistance Isolation Capacitance Switching Frequency Remote On/Off (Note 3) Parameter Supply On Supply Off Standby Input Current Control Common Conditions 60 Seconds Flash Tested For 1 Sec 500 VDC 100 kHz, 1V Min. 1,500 1,650 1,000 290 Conditions Typ. Max. 1,200 330 1,500 400 Min. 2.5 -0.7 Typ. Min. -40 Typ. +25 Units VDC VDC M⍀ pF kHz Max. Units 5.5 VDC 0.8 VDC 10 mA Referenced to Negative Input (pin 2) Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity RFI Physical Case Size Case Material Weight Conditions Ambient Case -50 Free Air Convection RH, Non-condensing Six-Side Shielded Metal Case Max. +60 +100 +125 Units °C °C °C 95 % 2.0 x 1.0 x 0.40 Inches (50.8 x 25.4 x 10.2 mm) Metal with Non-Conductive Base 1.06 Oz (30g) Reliability Specifications Parameter MTBF Conditions MIL HDBK 217F, 25°C, Gnd Benign Min. 700 Typ. Max. Units kHours Conditions 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec All Models Min. -0.7 -0.7 -0.7 Typ. Max. 25.0 50.0 100.0 260.0 5,000 Units Absolute Maximum Ratings Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com VDC °C mW www.micropowerdirect.com Model Selection Guide Model Number B1501RW B1502RW B1503RW B1504RW B1505RW B1506RW B1511RW B1512RW B1513RW B1514RW B1515RW B1516RW B1521RW B1522RW B1523RW B1524RW B1525RW B1526RW Input Reflected Ripple Current Voltage Voltage (VDC) Current (mA) Nominal Range Full-Load No-Load (mA, Typ) 12 9.0 - 18.0 1,056 30 50 12 9.0 - 18.0 1,543 30 50 12 9.0 - 18.0 1,452 30 50 12 9.0 - 18.0 1,452 30 50 12 9.0 - 18.0 1,452 30 50 12 9.0 - 18.0 1,452 30 50 24 18.0 - 36.0 528 17 40 24 18.0 - 36.0 772 17 40 24 18.0 - 36.0 726 17 40 24 18.0 - 36.0 726 17 40 24 18.0 - 36.0 726 17 40 24 18.0 - 36.0 726 17 40 48 36.0 - 75.0 264 10 30 48 36.0 - 75.0 385 10 30 48 36.0 - 75.0 363 10 30 48 36.0 - 75.0 363 10 30 48 36.0 - 75.0 363 10 30 48 36.0 - 75.0 363 10 30 Output Current Current (VDC) (mA, Max) (mA, Min) 3.3 5.0 12.0 15.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 ±12.0 ±15.0 3,000.0 3,000.0 1,250.0 1,000.0 ±625.0 ±500.0 3,000.0 3,000.0 1,250.0 1,000.0 ±625.0 ±500.0 3,000.0 3,000.0 1,250.0 1,000.0 ±625.0 ±500.0 300.0 300.0 125.0 100.0 ±62.5 ±50.0 300.0 300.0 125.0 100.0 ±62.5 ±50.0 300.0 300.0 125.0 100.0 ±62.5 ±50.0 Over Fuse Rating Voltage Efficiency Capacitive Load Slow-Blow Protection (%, Typ) (µF Max) (mA) (VDC) 3.9 6.8 15.0 18.0 ±15.0 ±18.0 3.9 6.8 15.0 18.0 ±15.0 ±18.0 3.9 6.8 15.0 18.0 ±15.0 ±18.0 78 81 86 86 86 86 78 81 86 86 86 86 78 81 86 86 86 86 470 470 470 470 ±220 ±220 470 470 470 470 ±220 ±220 470 470 470 470 ±220 ±220 3,000 3,000 3,000 3,000 3,000 3,000 1,500 1,500 1,500 1,500 1,500 1,500 750 750 750 750 750 750 For Class “A” filter option, add suffix “F” to model number (i.e. B1503RW-F) Derating Curve For heatsink option, add suffix “H” to model number (i.e. B1503RW-H) For Remote Control option, add suffix “R” to model number (i.e. B1503RW-R) Notes: 1. An internal filter that complies with EN55022 Class “A” is available. Add a suffix “-F” to the model number. 2. When measuring output ripple, it is recommended that an external 4.7 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 3. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 4. The maximum control current at the on/off pin (pin 6) during a logic high is 50 µA. The maximum control current to the on/off pin at logic low is -1 mA. If the on/off pin is left open, the unit operates. If it is grounded, the unit will shut off. 5. Operation at no-load will not damage these units. However, they may not meet all specifications. 6. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 7. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low Equivalent Series Resistance (ESR <1.0⍀ at 100 kHz) capacitor be mounted close to the converter. A 10.0 µF is recommended. 8. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Mechanical Dimensions Heatsink Dimensions (Optional) Pin Connections Heatsink Notes: Pin Single Dual 1 +Vin +Vin 2 -Vin -Vin 3 +Vout +Vout 4 No Pin Comm. 5 -Vout -Vout 6 ON/OFF ON/OFF • Use of the heatsink will extend the units operating temperature range by approximately 10°C. • The heatsink is black anodized aluminum. MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Mechanical Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) FAX: (781) 344-8481 • E-Mail: [email protected]