MA600x-xxRW Datasheet

MA600RW Series
Wide 2:1 Input, 6W,
Single & Dual Output
DC/DC Converters
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 6W Output Power
Input
Parameter
• 2:1 Input Voltage Range
Input Start Voltage
• 1,500 VDC Isolation
• 24 Standard Models
• Single & Dual Outputs
• Compact DIP Case
• -40°C to +85°C Operation
• Industry Standard Pin-Out
Under Voltage Shutdown
Input Filter
Typ.
8.0
16.0
34.0
Conditions
Typ.
±1.0
±1.0
±0.1
±0.6
Max.
9.0
18.0
36.0
8.5
16.0
35.0
Units
Max.
±2.0
±2.0
±0.5
±1.2
70
100
600
Units
%
%
%
%
VDC
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Min.
Dual Output, Balanced Loads
VIN = Min to Max
IOUT = 0% to 100%
See Note 1
Over Line, Load & Temp.
Ripple & Noise (20 MHz)
3.0 kV Isolation
Models
Available
Conditions
Min.
12 VDC Input
7.0
24 VDC Input 14.0
48 VDC Input 32.0
12 VDC Input
24 VDC Input
48 VDC Input
(Pi) Filter
Transient Recovery Time, See Note 2
Transient Response Deviation
Temperature Coefficient
Output Overload Protection
Output Short Circuit
300
25% Load Step Change
±3.0
±0.01
Foldback
110
145
Continuous (Autorecovery)
±0.02
Conditions
Max.
mV P - P
µSec
%
%/°C
%
General
4:1 Input Range
Models
Available
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
60 Seconds
500 VDC
100 kHz/1.0V
Standard
See Note 3
See Note 3
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Min.
1,500
1,000
Typ.
1,000
330
Units
VDC
M
pF
kHz
Level
Class A
Class A
Criteria A; ±8 kV Air ±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV
Criteria A; ±1 kV
Criteria A; 10V/m
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-50
Free Air Convection
RH, Non-condensing
Max.
+85
+100
+125
Units
°C
°C
°C
95
%
1.25 x 0.80 x 0.40 Inches (31.75 x 20.32 x 10.16 mm)
Non-Conductive Black Plastic (UL94-V0)
0.45 Oz (12.8g)
Reliability Specifications
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
-0.7
-0.7
-0.7
Typ.
Max.
25.0
50.0
100.0
260
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MA612S-03RW
MA612S-05RW
MA612S-12RW
MA612S-15RW
MA612S-24RW
MA612D-05RW
MA612D-12RW
MA612D-15RW
MA624S-05RW
MA624S-05RW
MA624S-12RW
MA624S-15RW
MA624S-24RW
MA624D-05RW
MA624D-12RW
MA624D-15RW
MA648S-03RW
MA648S-05RW
MA648S-12RW
MA648S-15RW
MA648S-24RW
MA648D-05RW
MA648D-12RW
MA648D-15RW
Voltage (VDC)
Nominal
Range
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
36.0 - 72.0
Output
Current (mA)
Voltage Current
(mA, Max)
Full-Load No-Load (VDC)
440
641
609
609
595
534
609
609
214
313
298
298
298
260
298
298
107
156
149
149
149
130
149
149
40
40
40
40
40
40
40
40
20
20
20
20
20
20
20
20
10
10
10
10
10
10
10
10
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
Current
(mA, Min)
1,200.0
1,200.0
500.0
400.0
250.0
±500.0
±250.0
±200.0
1,200.0
1,200.0
500.0
400.0
250.0
±500.0
±250.0
±200.0
1,200.0
1,200.0
500.0
400.0
250.0
±500.0
±250.0
±200.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
0.0
0.0
0.0
0.0
0.0
±0.0
±0.0
±0.0
Notes:
1. When measuring output ripple, it is recommended that an external 3.3 µF ceramic capacitor be placed from the
+VOUT pin to the -VOUT pin for single output units and from each output to common for dual output units.
2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%.
3. Operation at no-load will not damage these units.
4. An external 220 µF/100V capacitor connected across the input pins is required to meet EN61000-4-4 and
EN61000-4-5.
5. Dual output units may be connected to provide a 10, 24 or 30 VDC output. To do this, connect the load across the
positive (+VOUT) and negative (-VOUT) outputs and float the output common.
6. The converter should be connected to a low ac-impedance source. An input source with a
highly inductive impedance may affect the stability of the converter. In applications where
the converter output loading is high and input power is supplied over long lines, it may be
necessary to use a capacitor on the input to insure start-up. In this case, it is recommended
that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For
12V input units a 3.3 µF is recommended; and for 24V & 48V units a 2.2 µF.
7. It is recommended that a fuse be used on the input of a power supply for protection. See
the table above for the correct rating.
Efficiency
(%, Typ)
Fuse
Reflected Capacitive
Ripple
Rating
Load
Current
Slow-Blow
(µF, Max)
(mA Typ)
75
78
82
82
84
78
82
82
77
80
84
84
84
80
84
84
77
80
84
84
84
80
84
84
(mA)
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
470
470
100
100
47
±100
±100
±100
470
470
100
100
47
±100
±100
±100
470
470
100
100
47
±100
±100
±100
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
700
700
700
700
700
700
700
700
350
350
350
350
350
350
350
350
For 3 kV Isolation, See MA600x-xxRWI Series Datasheet
For 4:1 Inputs, See MA600x-xxRU Series Datasheet
Mechanical Dimensions
Derating Curve
Pin Connections
Pin
Single
Dual
2, 3
9
11
14
16
22, 23
-VIN
No Pin
NC
+V
VOUT
-V
VOUT
+VIN
-VIN
Common
-V
VOUT
+V
VOUT
Common
+VIN
NC: No Connection
Mechanical Notes:
MicroPower Direct
• All dimensions are typical in inches (mm)
• Tolerance x.x = ±0.02 (±0.50)
• Tolerance x.xx = ±0.01 (±0.25)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]