LF100ED Datasheet - Micropower Direct

LF100ED Series
Low Cost, Dual Output
Ultra-Miniature 1W SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 1W Output Power
• Ultra-Miniature SMT Case
• EN60950 Approved
• Dual Outputs
• Low 0.26” Profile
• 1,000 VDC Isolation
• >3.5 MHour MTBF
• 3.3V, 5V, & 12V Inputs
• LOW COST!
Input
Parameter
Conditions
3.3 VDC Input
Input Voltage Range
Min.
Typ.
Max.
3.0
3.3
3.6
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
Reverse Polarity Input Current
Input Filter
Units
VDC
1.0
A
Max.
Units
Capacitor
Output
Parameter
Conditions
Min.
Output Voltage Accuracy
Typ.
±3.0
Output Voltage Balance
Balanced Loads
Line Regulation
For Vin Change of 1%
Load Regulation, See Note 1
%
±1.0
%
±1.2
%
See Model Selection Guide
Ripple & Noise (20 MHz)
See Note 2
50
Temperature Coefficient
Output Short Circuit
75
mV P - P
±0.03
%/ºC
Max.
Units
Momentary (0.5 Sec.)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
1,000
500 VDC
1,000
100 kHz, 0.1V
Switching Frequency
Typ.
VDC
M
30
pF
100
kHz
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Storage Temperature Range
Min.
Typ.
Max.
-40
+25
+85
ºC
+125
ºC
95
%
-55
Cooling
Units
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
See Mechanical Drawing (Page 2)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
0.05 Oz (1.5g)
Reliability Specifications
MicroPower Direct
Parameter
292 Page Street
Suite D
Stoughton, MA 02072
USA
MTBF
Conditions
Safety Standards
Typ.
Max.
3.5
Units
MHours
UL 1950, EN 60950
Absolute Maximum Ratings
Parameter
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Conditions
Input Voltage Surge (1 Sec)
Peak Reflow Temperature
Lead Temperature
Internal Power Dissipation
Min.
Typ.
Max.
3.3 VDC Input
-0.7
5 VDC Input
-0.7
7.0
12 VDC Input
-0.7
15.0
Units
5.0
VDC
See Note 5
245
1.5 mm From Case For 10 Sec
300
ºC
All Models
450
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
ºC
www.micropowerdirect.com
Model Selection Guide
Model
Number
LF101ED
LF102ED
LF103ED
LF104ED
LF111ED
LF112ED
LF113ED
LF114ED
LF151ED
LF152ED
LF153ED
Input
Voltage (VDC)
Current (mA)
Nominal
Range
Full-Load No-Load
5
4.5 - 5.5
282
30
5
4.5 - 5.5
260
30
5
4.5 - 5.5
256
30
5
4.5 - 5.5
256
30
12
10.8 - 13.2
117
20
12
10.8 - 13.2
114
20
12
10.8 - 13.2
113
20
12
10.8 - 13.2
113
20
3.3
3.0 - 3.6
427
40
3.3
3.0 - 3.6
383
40
3.3
3.0 - 3.6
383
40
Voltage
Output
Current
Current
Load
Regulation
(VDC)
(mA, Max)
(mA, Min)
(%, Max)
±5.0
±9.0
±12.0
±15.0
±5.0
±9.0
±12.0
±15.0
±5.0
±12.0
±15.0
±100.0
±56.0
±42.0
±33.0
±100.0
±56.0
±42.0
±33.0
±100.0
±42.0
±33.0
Notes:
1. Output load regulation is specified for a load change of 20% to 100%.
2. When measuring output ripple, it is recommended that external 1.0 µF and a 10 µF capacitors be placed
in parallel from each output to common.
3. During operation, care must be taken not to exceed the specified input range of the unit or to allow the
output load to drop below the specified minimum (10% of full load). Operating the unit under either
of these conditions could cause damage to the unit.
4. These converters are specified for operation without external components. However, in some applications the addition of input/output capacitors will enhance stability and reduce output ripple.
Recommended capacitor values are:
±10.0
±5.6
±4.2
±3.3
±10.0
±5.6
±4.2
±3.3
±10.0
±4.2
±3.3
12.0
8.0
7.0
6.0
12.0
8.0
7.0
6.0
12.0
7.0
6.0
Rating
Efficiency Fuse
Slow-Blow
(%, Typ)
(mA)
71
77
78
78
71
73
74
74
71
79
79
500
500
500
500
200
200
200
200
750
750
750
Derating Curve
Input
Output
Vout
Capacitor
Capacitor
5 VDC
4.7 µF
5 VDC
4.7 µF
12 VDC
2.2 µF
9 VDC
2.2 µF
24 VDC
1.0 µF
12 VDC
1.0 µF
15 VDC
0.47 µF
Vin
For applications requiring very low output noise levels, a
simple LC filter should be effective.
5. The recommended time above liquidous (TL) is <60 seconds at
217 °C. A suggested temperature profile is shown at right. For
more information, please contact the factory.
6. It is recommended that a fuse be used on the input of a
power supply for protection. See the Model Selection table
above for the correct rating.
Pin Connections
Pin
1
2
3
4
5
Mechanical Dimensions
Description
Pin Description
-Vin
6
NC
+Vin
7
+Vout
NC
8
NC
Common
9
NC
-Vout
10
NC
NC = No Connection
Recommended Solder Profile
Board Layout
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation on the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]