ML100S Datasheet - Micropower Direct

ML100S Series
Ultra-Miniature, 1W
Single Output SMT
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
• 1W Output Power
• Ultra-Miniature SMT Case
• 1,500 VDC Isolation
• 5V, 12, 15 & 24V Inputs
• -40ºC to +85ºC Operation
• 17 Standard Models
• 2.0 MH MTBF Minimum
• Available on Tape/Reel
Parameter
Conditions
Input Voltage Range
Min.
Typ.
Max.
5 VDC Input
4.5
5.0
5.5
12 VDC Input
10.8
12.0
13.2
15 VDC Input
13.5
15.0
16.5
24 VDC Input
21.6
24.0
26.4
Reverse Polarity Input Current
Input Filter
Units
VDC
0.3
A
Max.
Units
Capacitor
Output
Parameter
Conditions
Min.
Output Voltage Accuracy
Typ.
±5.0
Line Regulation
For Vin Change of 1%
Load Regulation, See Note 1
±1.2
%
±1.5
%
See Model Selection Guide
Ripple & Noise (20 MHz)
See Note 2
Temperature Coefficient
±0.01
Output Short Circuit
120
mV P - P
±0.02
%/ºC
Max.
Units
Momentary (0.5 Sec.)
General
Parameter
Conditions
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Min.
60 Seconds
1,500
500 VDC
1,000
100 kHz, 1V
Switching Frequency
Typ.
VDC
M
40
100
pF
50
100
140
kHz
Min.
Typ.
Max.
Units
-40
+25
+85
ºC
+90
ºC
+125
ºC
95
%
Environmental
Parameter
Conditions
Operating Temperature Range
Ambient
Operating Temperature Range
Case
Storage Temperature Range
-50
Cooling
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
See Mechanical Drawing (Page 2)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
0.06 Oz (1.7g)
Reliability Specifications
Parameter
Conditions
MTBF
Min.
MIL HDBK 217F, 25ºC, Gnd Benign
Typ.
Max.
2.0
Units
MHours
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Peak Reflow Temperature
Lead Temperature
Internal Power Dissipation
Min.
Typ.
Max.
5 VDC Input
-0.7
9.0
12 VDC Input
-0.7
18.0
15 VDC Input
-0.7
20.0
24 VDC Input
-0.7
30.0
Units
VDC
See Note 3
245
1.5 mm From Case For 10 Sec.
260
ºC
All Models
450
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
ºC
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
ML105S-03
ML105S-05
ML105S-09
ML105S-12
ML105S-15
ML112S-03
ML112S-05
ML112S-09
ML112S-12
ML112S-15
ML115S-12
ML115S-15
ML124S-03
ML124S-05
ML124S-09
ML124S-12
ML124S-15
Output
Voltage (VDC)
Current (mA)
Voltage
Nominal
Range
Full-Load No-Load (VDC)
5
4.50 - 5.50
271
30
3.3
5
4.50 - 5.50
256
30
5.0
5
4.50 - 5.50
254
30
9.0
5
4.50 - 5.50
259
30
12.0
5
4.50 - 5.50
254
30
15.0
12
10.8 - 13.2
112
15
3.3
12
10.8 - 13.2
109
15
5.0
12
10.8 - 13.2
106
15
9.0
12
10.8 - 13.2
106
15
12.0
12
10.8 - 13.2
105
15
15.0
15
13.5 - 16.5
86
14
12.0
15
13.5 - 16.5
86
14
15.0
24
21.6 - 26.4
58
8
3.3
24
21.6 - 26.4
54
8
5.0
24
21.6 - 26.4
54
8
9.0
24
21.6 - 26.4
55
8
12.0
24
21.6 - 26.4
53
8
15.0
Notes:
1. Load regulation is measured for an output change of 20% to 100%.
2. When measuring output ripple, it is recommended that an external 0.33 µF ceramic capacitor
be placed from the +Vout pin to the -Vout pin. For noise sensitive applications, the use of 3.3
µF capacitors will reduce the output ripple.
3. The recommended time above liquidous (TL) is <60 seconds at 217 °C. For
more information, please contact the factory.
4. Operation at no-load will not damage these units. However, they may not meet all specifications.
5. The converter should be connected to a low ac-impedance source. An input source with a
highly inductive impedance may affect the stability of the converter. In applications where
the converter output loading is high and input power is supplied over long lines, it may be
necessary to use a capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted
close to the converter. For 5V input units a 2.2 µF is recommended; a 1.0 µF for 12V & 15V
input units; and for 24V input models, a 0.47 µF.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the
table above for the correct rating.
Current
Current
(mA, Max)
(mA, Min)
300
200
110
84
67
300
200
110
84
67
84
67
300
200
110
84
67
Output
Load
Rating
ciency Capacitive Fuse
Regulation Effi
Slow-Blow
(%, Typ)
Load
(%, Max)
(mA)
(µF, Max)
6.0
4.0
2.0
1.5
1.0
6.0
4.0
2.0
1.5
1.0
1.5
1.0
6.0
4.0
2.0
1.5
1.0
10
10
10
8
7
8
8
8
5
5
5
5
8
8
8
5
5
73
78
78
78
79
74
76
78
79
80
78
78
72
78
77
77
79
500
500
500
500
500
200
200
200
200
200
150
150
100
100
100
100
100
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
33
Derating Curve
Mechanical Dimensions
Board Layout
Pin Connections
Pin
Description
1
-Vin
2
+Vin
3
No Pin
4
-Vout
5
+Vout
6
No Pin
7
No Pin
8
NA
NA = Not for electrical connection
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” or indentation
on the unit
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]