Test Report: GST90A19-P1M 90W AC-DC High Reliability Industrial Adaptor DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C. Test RELIABILITY TEST ENVIRONMENT TEST 90W AC-DC High Reliability Industrial Adaptor GST90A series DESIGN VERIFY TEST OUTPUT FUNCTION TEST NO 1 3 4 5 6 7 8 9 10 TEST ITEM SPECIFICATION TEST CONDITION RESULT RIPPLE & NOISE(Max ) V1:180mVp-p I/P:230VAC O/P:FULL LOAD Ta:25℃ V1: 43.2mVp-p (Max ) I/P: 100VAC /264VAC O/P:FULL/ MIN. LOAD Ta:25℃ V1: -0.753 %~0.721 I/P: 100VAC~ 264VAC O/P:FULL LOAD Ta:25℃ V1: 0 %~0 % I/P: 230VAC O/P:FULL ~MIN LOAD Ta:25℃ V1: -0.753 %~ 0.721 % 230VAC/1000ms 115VAC/1000ms I/P: 230 VAC I/P: 115 VAC O/P:FULL LOAD Ta:25℃ 230VAC/ 99.710 ms 115VAC/421.909 ms 230VAC/50ms 115VAC/50ms I/P: 230 VAC I/P: 115 VAC O/P:FULL LOAD Ta:25℃ 230VAC/ 21.464 ms 115VAC/ 21.556 ms I/P: 230 VAC I/P: 115 VAC O/P:FULL LOAD Ta:25℃ 230VAC/ 34.500 ms 115VAC/ 23.029 ms OUTPUT VOLTAGE(Max) TOLERANCE V1: -4%~ 4% LINE REGULATION (Max) V1: -1%~ 1% LOAD REGULATION(Max) SET UP TIME(Max) RISE TIME (Max) HOLD UP TIME(Typ ) V1: -4%~ 4% 230VAC/20ms 115VAC/20ms OVER/UNDERSHOOT TEST DYNAMIC LOAD < +5% V1: 1900mVp-p I/P: 230VAC O/P:FULL LOAD Ta:25℃ I/P: 230VAC O/P(1)FULL /Min LOAD 90%DUTY / 1KHZ (2) (1)FULL /Min LOAD 90%DUTY / 3KHZ (3)FULL /Min LOAD 90%DUTY / 5KHZ (4)FULL /Min LOAD 50%DUTY / 120HZ Ta:25℃ VERDICT P % P P P P P P < +5% P 1000mVp-p 1040mVp-p 1110mVp-p 1060mVp-p P Model:GST90A19-P1M Test Report 2 / 7 GST90A 90W AC-DC High Reliability Industrial Adaptor series INPUT FUNCTION TEST NO 1 2 3 4 5 6 7 8 TEST ITEM SPECIFICATION INPUT VOLTAGE RANGE INPUT FREQUENCY RANGE 100VAC~264VAC EFFICIENCY(TYP) INRUSH CURRENT(Typ) LEAKAGE CURRENT NO LOAD CONSUMPTION RESULT I/P:TESTING O/P:FULL LOAD Ta:25℃ VERDICT 55.193 V~264V I/P: (1)LOW-LINE-3V=87 V HIGH-LINE+15%=300 V O/P:FULL/MIN LOAD ON: 30 Sec OFF: 30 Sec 10MIN (2)230Vac ON: 0.5 Sec OFF: 0.5 Sec 20MIN (3)230Vac ON:3Sec OFF:3Sec 12HOURS ( POWER ON/OFF NO DAMAGE ) TEST:OK I/P:100 VAC ~264 VAC O/P:FULL~MIN LOAD Ta:25℃ TEST: 0.91/ 230VAC 0.95/115VAC I/P: 230 VAC I/P: 115 VAC O/P:FULL LOAD Ta:25℃ PF=0.964/230VAC PF=0.988/115VAC 90% I/P:230 VAC O/P:FULL LOAD Ta:25℃ 47HZ ~63 HZ NO DAMAGE POWER FACTOR(TYP) INPUT CURRENT (Typ) TEST CONDITION P OK P 90.15% P 230V/ 0.6A 115V/ 1.3A I/P: 230 VAC I/P: 115 VAC O/P:FULL LOAD Ta:25℃ I =0.442A/ 230VAC I =0.870A/ 115VAC 230V/70A COLD START I/P: 230 VAC O/P:FULL LOAD Ta:25℃ I = 45.65 A/ 230VAC I/P: 240 VAC O/P:Min LOAD Ta:25℃ L-FG: 0.53 N-FG: 0.53 I/P:115VAC I/P:230VAC O/P:NO LOAD Ta:25℃ < < < < 1 0.15 mA / 240 VAC W P P P mA mA P 0.0514W 0.0643W Model:GST90A19-P1M P Test Report 3 / 7 90W AC-DC High Reliability Industrial Adaptor GST90A series PROTECTION FUNCTION TEST NO 1 2 3 4 TEST ITEM SPECIFICATION OVER LOAD PROTECTION OVER VOLTAGE PROTECTION OVER PROTECTION TEMPERATURE SHORT PROTECTION 105%~ 150% CH:19.95V~25.65V NO DAMAGE SHORT EVERY OUTPUT 1 HOUR NO DAMAGE TEST CONDITION RESULT VERDICT I/P: 230VAC I/P: 115VAC O/P:TESTING Ta:25℃ 131.65%/ 230VAC 125.53%/115VAC Hiccup Mode I/P: 230VAC I/P: 115VAC O/P:MIN LOAD Ta:25℃ 23.5V/ 230VAC 23.5V/ 115VAC Shut down Re- power ON P I/P: 230 VAC O/P:FULL LOAD O.T.P. Active Shunt down Re-power ON P I/P: 264VAC O/P: FULL LOAD Ta:25℃ NO DAMAGE Hiccup Mode P P COMPONENT STRESS TEST NO 1 2 TEST ITEM SPECIFICATION TEST CONDITION RESULT PWM Transistor ( D to S) or (C to E) Peak Voltage Q32 Rated 11A/700V I/P:High-Line +3V =267V AC ON/OFF O/P: (1)Full Load (2)Output Short (3) Full Load Continue Ta:25℃ (1) 584V (2) 498V (3) 574V I/P:High-Line +3V =267 V AC ON/OFF O/P: (1)Full Load (2)Output Short (3)0%→400% Load. Q101: (1) 108V (2) 92.0V (3) 116V (4) 113V Diode Peak Voltage Q101 Rated 75A/120V VERDICT P P (4).NO LOAD Ta:25℃ 3 4 6 Input Capacitor Voltage Control IC Voltage Test P.F.C Transistor ( D to S) or (C to E) Peak Voltage C5 Rated: : 100u/400V 105℃ PWM IC U1 Rated 28 V Q31 Rated 15.8A/600V I/P:High-Line +3V =267 V O/P: (1)Full Load input on/off (2) Min load input on /Off (3)Full Load /Min load Change Ta:25℃ (1)398V (2) 400V (3) 396V I/P:High-Line +3V =267 V AC ON/OFF O/P(1)FULL LOAD (2) Output Short (3)O.L.P (4)O.V.P. (5)NO LOAD VR MIN LOW LINE Ta:25℃ (1) 19.9V (2) 15.2V (3) 15.3V (4) 23.0V (5) 18.3V I/P:High-Line +3V =267 V AC ON/OFF O/P: (1)Full Load (2)Output Short (3) Full Load Continue Ta:25℃ (1) (2) (3) P P 440V 410V 416V Model:GST90A19-P1M P Test Report 4 / 7 GST90A 90W AC-DC High Reliability Industrial Adaptor 7 8 P.F.C DIODE Clamp Diode Peak Voltage D1 D30 Rated 4A/600V Rated: 800V/ 2A I/P:High-Line +3V =267 V AC ON/OFF O/P: (1)Full Load (2)Output Short (3)Dynamic Load 100% Load/ Min. Load 50%Duty/120Hz Ta:25℃ (1) (2) (3) I/P:High-Line +3V = 267 V (1) (2) AC ON/OFF O/P: (1) Dynamic Load series 428V 422V 424V P 538 536 V V P 90%Duty/1KHz (2)Full load continue Ta:25℃ SAFETY TEST NO 1 2 3 TEST ITEM SPECIFICATION TEST CONDITION RESULT WITHSTAND VOLTAGE I/P-O/P: 3KVAC/min I/P-FG :2KVAC/min O/P-FG:0.5KVAC/min I/P-O/P: 3.6 KVAC/min I/P-FG: 2.4 KVAC/min O/P-FG:0.6 KVAC/min Ta:25℃ I/P-O/P: 2.433mA I/P-FG: 2.711mA O/P-FG:1.461 mA NO DAMAGE P I/P-O/P:500VDC>100MΩ I/P-FG: 500VDC>100MΩ O/P-FG:500VDC>100MΩ I/P-O/P: 500 VDC I/P-FG: 500 VDC O/P-FG: 500 VDC Ta:25℃ I/P-O/P:9999 MΩ I/P-FG: 9999MΩ O/P-FG: 9999MΩ NO DAMAGE P FG(PE) TO CHASSIS OR TRACE < 100 mΩ 40A / 2min Ta:25℃ ISOLATION RESISTANCE GROUNDING CONTINUITY VERDICT 15 mΩ BY PCB P E.M.C TEST NO 1 2 3 4 5 6 7 TEST ITEM SPECIFICATION TEST CONDITION RESULT HARMONIC EN61000-3-2 CLASS A I/P:230VAC/50HZ O/P:100%,75%,50%OAD Ta:25℃ PASS EN55022 CLASS B I/P: 230 VAC (50HZ) O/P:FULL/50% LOAD Ta:25℃ PASS Test by certified Lab P EN55022 CLASS B I/P: 230 VAC (50HZ) O/P:FULL LOAD Ta:25℃ PASS Test by certified Lab P EN61000-4-2 LIGHT INDUSTRY AIR:8KV / Contact:4KV I/P: 230 VAC/50HZ O/P:FULL LOAD Ta:25℃ CRITERIA A EN61000-4-4 LIGHT INDUSTRY INPUT: 1KV I/P: 230 VAC/50HZ O/P:FULL LOAD Ta:25℃ CRITERIA A IEC61000-4-5 LIGHT INDUSTRY L-N :1KV L,N-PE:2KV I/P: 230 VAC/50HZ O/P:FULL LOAD Ta:25℃ CRITERIA A CONDUCTION RADIATION E.S.D E.F.T SURGE VERDICT P P P P Test by certified Lab & Test Report Prepare Model:GST90A19-P1M Test Report 5 / 7 GST90A 90W AC-DC High Reliability Industrial Adaptor series RELIABILITY TEST ENVIRONMENT TEST NO 1 2 3 4 5 TEST ITEM SPECIFICATION TEMPERATURE RISE TEST MODEL:GST90A15-P1M 1. ROOM AMBIENT BURN-IN:1 HRS I/P: 230VAC O/P: FULL LOAD Ta=22.5℃ 2. HIGH AMBIENT BURN-IN: 1 HRS I/P: 230VAC O/P: FULL LOAD Ta=44.9℃ TEST CONDITION RESULT ROOM AMBIENT HIGH AMBIENT Ta=22.5℃ Ta=44.9℃ NO Position 1 LF1 59.7℃ 78.2℃ 2 LF2 57.5℃ 77.2℃ 3 BD1 60.7℃ 80.1℃ 4 LF3 63.6℃ 83.0℃ 5 L2 65.3℃ 84.3℃ 6 C5 65.9℃ 85.2℃ 7 D1 69.5℃ 85.7℃ 8 Q31 65.4℃ 84.9℃ 9 Q32 67.3℃ 87.0℃ 10 D30 77.8℃ 97.8℃ 11 C52 66.8℃ 86.2℃ 12 T1 75.2℃ 94.7℃ 13 RTH30 65.3℃ 84.7℃ 14 Q101 64.6℃ 83.9℃ 15 CASE 50.8℃ 71.0℃ 16 Q102 61.5℃ 81.4℃ 17 C109 64.5℃ 84.3℃ 18 U2 63.8℃ 83.0℃ 19 R56 67.2℃ 84.5℃ 20 R64 67.2℃ 86.7℃ 21 R58 70.4℃ 90.2℃ 22 LF101 58.7℃ 79.3℃ NO DAMAGE 1 HOUR ( MIN ) I/P: 230 VAC O/P:126﹪LOAD Ta:25℃ TEST:OK LOW TEMPERATURE TURN ON TEST TURN ON AFTER 2 HOUR I/P: 264VAC/100VAC O/P: 100 ﹪LOAD Ta=-30℃ TEST:OK HIGH HUMIDITY HIGH TEMPERATURE HIGH VOLTAGE TURN ON TEST AFTER 12 HOURS IN CHAMBER ON CONTROL 40℃ I/P: 272 VAC O/P:FULL LOAD Ta=40℃ TEST:OK NO DAMAGE HUMIDITY= 95 %R.H OVER LOAD BURN-IN TEST TEMPERATURE COEFFICIENT +0.03%/℃(0~40℃) VERDICT I/P: 230 VAC O/P:FULL LOAD P P P P +0.012%/℃(0~40℃) P Model:GST90A19-P1M Test Report 6 / 7 GST90A 90W AC-DC High Reliability Industrial Adaptor 6 7 8 9 10 11 STORAGE TEMPERATURE TEST THERMAL SHOCK TEST VIBRATION TEST CAPACITOR LIFE CYCLE MTBF DMTBF/Accelerated Life Test 1. 2. 3. 4. 5. Thermal shock Temperature: -40℃~ +85℃ Temperature change rate :25℃ / MIN Dwell time low and high temperature : 30 MIN/EACH Total test cycle:5 CYCLE Input/Output condition: STATIC TEST:OK 1. 2. 3. 4. 5. Thermal shock Temperature: -30℃~ +70℃ Temperature change rate :25℃ / MIN Dwell time low and high temperature : 30 MIN/EACH Total test cycle:10 CYCLE Input/Output condition: 230VAC/Full Load AC ON/OFF TEST turn on 58sec;turn off 2sec TEST:OK 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:12min/sweep cycle (4) Acceleration:2G (5) Test Time:60min in each axis (X.Y.Z) (6) Ta:25℃ SUPPOSE C109 IS THE MOST CRITICAL COMPONENT (1) I/P: 230VAC O/P:FULL LOAD Ta=25℃ LIFE TIME (2) I/P: 230VAC O/P:FULL LOAD Ta=40℃ LIFE TIME (3) I/P: 230VAC O/P:75% LOAD Ta=40℃ LIFE TIME (4) I/P: 230VAC O/P:50% LOAD Ta=40℃ LIFE TIME MIL-HDBK-217F TOTAL FAILURE RATE:348.7KHRS series P P TEST:OK P (1) (2) (3) (4) 171060 HRS 72452 HRS 127834 HRS 240196 HRS P P Demonstration Mean Time Between Failure (Expected Life): Above 50,000 hours @ TA 50℃ TEST RESULT TESTER APPROVAL PASS FRANK WANGDZ 2007/3/20 Model:GST90A19-P1M P A50-S014 Test Report 7 / 7