Test Report: GST90A19-P1M

Test Report: GST90A19-P1M
90W AC-DC High Reliability Industrial Adaptor
 DESIGN VERIFY TEST
Output Function Test
Input Function Test
Protection Function Test
Component Stress Test
 SAFETY & E.M.C. TEST
Safety Test
E.M.C. Test
 RELIABILITY TEST
ENVIRONMENT TEST
90W AC-DC High Reliability Industrial Adaptor
GST90A
series
 DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO
1
3
4
5
6
7
8
9
10
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
RIPPLE & NOISE(Max )
V1:180mVp-p
I/P:230VAC
O/P:FULL LOAD
Ta:25℃
V1: 43.2mVp-p (Max )
I/P: 100VAC /264VAC
O/P:FULL/ MIN. LOAD
Ta:25℃
V1: -0.753 %~0.721
I/P: 100VAC~ 264VAC
O/P:FULL LOAD
Ta:25℃
V1: 0 %~0 %
I/P: 230VAC
O/P:FULL ~MIN LOAD
Ta:25℃
V1: -0.753 %~ 0.721 %
230VAC/1000ms
115VAC/1000ms
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230VAC/ 99.710 ms
115VAC/421.909 ms
230VAC/50ms
115VAC/50ms
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230VAC/ 21.464 ms
115VAC/ 21.556 ms
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
230VAC/ 34.500 ms
115VAC/ 23.029 ms
OUTPUT VOLTAGE(Max)
TOLERANCE
V1: -4%~ 4%
LINE REGULATION (Max)
V1: -1%~ 1%
LOAD REGULATION(Max)
SET UP TIME(Max)
RISE TIME (Max)
HOLD UP TIME(Typ )
V1: -4%~ 4%
230VAC/20ms
115VAC/20ms
OVER/UNDERSHOOT TEST
DYNAMIC LOAD
< +5%
V1:
1900mVp-p
I/P: 230VAC
O/P:FULL LOAD
Ta:25℃
I/P: 230VAC
O/P(1)FULL /Min LOAD
90%DUTY / 1KHZ
(2) (1)FULL /Min LOAD
90%DUTY / 3KHZ
(3)FULL /Min LOAD
90%DUTY / 5KHZ
(4)FULL /Min LOAD
50%DUTY / 120HZ
Ta:25℃
VERDICT
P
%
P
P
P
P
P
P
< +5%
P
1000mVp-p
1040mVp-p
1110mVp-p
1060mVp-p
P
Model:GST90A19-P1M
Test Report
2 / 7
GST90A
90W AC-DC High Reliability Industrial Adaptor
series
INPUT FUNCTION TEST
NO
1
2
3
4
5
6
7
8
TEST ITEM
SPECIFICATION
INPUT VOLTAGE RANGE
INPUT FREQUENCY RANGE
100VAC~264VAC
EFFICIENCY(TYP)
INRUSH CURRENT(Typ)
LEAKAGE CURRENT
NO LOAD CONSUMPTION
RESULT
I/P:TESTING
O/P:FULL LOAD
Ta:25℃
VERDICT
55.193 V~264V
I/P:
(1)LOW-LINE-3V=87 V
HIGH-LINE+15%=300 V
O/P:FULL/MIN LOAD
ON: 30 Sec OFF: 30 Sec 10MIN
(2)230Vac
ON: 0.5 Sec OFF: 0.5 Sec 20MIN
(3)230Vac
ON:3Sec OFF:3Sec 12HOURS
( POWER ON/OFF NO DAMAGE )
TEST:OK
I/P:100 VAC ~264 VAC
O/P:FULL~MIN LOAD
Ta:25℃
TEST:
0.91/ 230VAC
0.95/115VAC
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
PF=0.964/230VAC
PF=0.988/115VAC
90%
I/P:230 VAC
O/P:FULL LOAD
Ta:25℃
47HZ ~63 HZ
NO DAMAGE
POWER FACTOR(TYP)
INPUT CURRENT (Typ)
TEST CONDITION
P
OK
P
90.15%
P
230V/ 0.6A
115V/ 1.3A
I/P: 230 VAC
I/P: 115 VAC
O/P:FULL LOAD
Ta:25℃
I =0.442A/ 230VAC
I =0.870A/ 115VAC
230V/70A
COLD START
I/P: 230 VAC
O/P:FULL LOAD
Ta:25℃
I = 45.65 A/ 230VAC
I/P: 240 VAC
O/P:Min LOAD
Ta:25℃
L-FG: 0.53
N-FG: 0.53
I/P:115VAC
I/P:230VAC
O/P:NO LOAD
Ta:25℃
<
<
<
<
1
0.15
mA / 240 VAC
W
P
P
P
mA
mA
P
0.0514W
0.0643W
Model:GST90A19-P1M
P
Test Report
3 / 7
90W AC-DC High Reliability Industrial Adaptor
GST90A
series
PROTECTION FUNCTION TEST
NO
1
2
3
4
TEST ITEM
SPECIFICATION
OVER LOAD PROTECTION
OVER VOLTAGE PROTECTION
OVER
PROTECTION
TEMPERATURE
SHORT PROTECTION
105%~ 150%
CH:19.95V~25.65V
NO DAMAGE
SHORT EVERY OUTPUT
1 HOUR NO DAMAGE
TEST CONDITION
RESULT
VERDICT
I/P: 230VAC
I/P: 115VAC
O/P:TESTING
Ta:25℃
131.65%/ 230VAC
125.53%/115VAC
Hiccup Mode
I/P: 230VAC
I/P: 115VAC
O/P:MIN LOAD
Ta:25℃
23.5V/ 230VAC
23.5V/ 115VAC
Shut down Re- power ON
P
I/P: 230 VAC
O/P:FULL LOAD
O.T.P. Active
Shunt down Re-power ON
P
I/P: 264VAC
O/P: FULL LOAD
Ta:25℃
NO DAMAGE
Hiccup Mode
P
P
COMPONENT STRESS TEST
NO
1
2
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
PWM Transistor
( D to S) or (C to E) Peak Voltage
Q32 Rated
11A/700V
I/P:High-Line +3V =267V
AC ON/OFF
O/P: (1)Full Load
(2)Output Short
(3) Full Load Continue
Ta:25℃
(1) 584V
(2) 498V
(3) 574V
I/P:High-Line +3V =267 V
AC ON/OFF
O/P: (1)Full Load
(2)Output Short
(3)0%→400% Load.
Q101:
(1) 108V
(2) 92.0V
(3) 116V
(4) 113V
Diode Peak Voltage
Q101
Rated
75A/120V
VERDICT
P
P
(4).NO LOAD
Ta:25℃
3
4
6
Input Capacitor Voltage
Control IC Voltage Test
P.F.C Transistor
( D to S) or (C to E) Peak Voltage
C5 Rated:
: 100u/400V 105℃
PWM IC U1 Rated
28 V
Q31 Rated
15.8A/600V
I/P:High-Line +3V =267 V
O/P: (1)Full Load input on/off
(2) Min load input on /Off
(3)Full Load /Min load Change
Ta:25℃
(1)398V
(2) 400V
(3) 396V
I/P:High-Line +3V =267 V
AC ON/OFF
O/P(1)FULL LOAD
(2) Output Short
(3)O.L.P
(4)O.V.P.
(5)NO LOAD VR MIN LOW LINE
Ta:25℃
(1) 19.9V
(2) 15.2V
(3) 15.3V
(4) 23.0V
(5) 18.3V
I/P:High-Line +3V =267 V
AC ON/OFF
O/P: (1)Full Load
(2)Output Short
(3) Full Load Continue
Ta:25℃
(1)
(2)
(3)
P
P
440V
410V
416V
Model:GST90A19-P1M
P
Test Report
4 / 7
GST90A
90W AC-DC High Reliability Industrial Adaptor
7
8
P.F.C DIODE
Clamp Diode Peak Voltage
D1
D30
Rated
4A/600V
Rated: 800V/ 2A
I/P:High-Line +3V =267 V
AC ON/OFF
O/P: (1)Full Load
(2)Output Short
(3)Dynamic Load 100% Load/
Min. Load 50%Duty/120Hz
Ta:25℃
(1)
(2)
(3)
I/P:High-Line +3V = 267 V
(1)
(2)
AC ON/OFF
O/P: (1) Dynamic Load
series
428V
422V
424V
P
538
536
V
V
P
90%Duty/1KHz
(2)Full load continue
Ta:25℃
SAFETY TEST
NO
1
2
3
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
WITHSTAND VOLTAGE
I/P-O/P: 3KVAC/min
I/P-FG :2KVAC/min
O/P-FG:0.5KVAC/min
I/P-O/P: 3.6 KVAC/min
I/P-FG: 2.4 KVAC/min
O/P-FG:0.6 KVAC/min
Ta:25℃
I/P-O/P: 2.433mA
I/P-FG: 2.711mA
O/P-FG:1.461 mA
NO DAMAGE
P
I/P-O/P:500VDC>100MΩ
I/P-FG: 500VDC>100MΩ
O/P-FG:500VDC>100MΩ
I/P-O/P: 500 VDC
I/P-FG: 500 VDC
O/P-FG: 500 VDC
Ta:25℃
I/P-O/P:9999 MΩ
I/P-FG: 9999MΩ
O/P-FG: 9999MΩ
NO DAMAGE
P
FG(PE) TO CHASSIS
OR TRACE < 100 mΩ
40A / 2min
Ta:25℃
ISOLATION RESISTANCE
GROUNDING CONTINUITY
VERDICT
15 mΩ BY PCB
P
E.M.C TEST
NO
1
2
3
4
5
6
7
TEST ITEM
SPECIFICATION
TEST CONDITION
RESULT
HARMONIC
EN61000-3-2
CLASS A
I/P:230VAC/50HZ
O/P:100%,75%,50%OAD
Ta:25℃
PASS
EN55022
CLASS B
I/P: 230 VAC (50HZ)
O/P:FULL/50% LOAD
Ta:25℃
PASS
Test by certified Lab
P
EN55022
CLASS B
I/P: 230 VAC (50HZ)
O/P:FULL LOAD
Ta:25℃
PASS
Test by certified Lab
P
EN61000-4-2
LIGHT INDUSTRY
AIR:8KV / Contact:4KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
EN61000-4-4
LIGHT INDUSTRY
INPUT: 1KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
IEC61000-4-5
LIGHT INDUSTRY
L-N :1KV
L,N-PE:2KV
I/P: 230 VAC/50HZ
O/P:FULL LOAD
Ta:25℃
CRITERIA A
CONDUCTION
RADIATION
E.S.D
E.F.T
SURGE
VERDICT
P
P
P
P
Test by certified Lab & Test Report Prepare
Model:GST90A19-P1M
Test Report
5 / 7
GST90A
90W AC-DC High Reliability Industrial Adaptor
series
 RELIABILITY TEST
ENVIRONMENT TEST
NO
1
2
3
4
5
TEST ITEM
SPECIFICATION
TEMPERATURE RISE TEST
MODEL:GST90A15-P1M
1. ROOM AMBIENT BURN-IN:1 HRS
I/P: 230VAC O/P: FULL LOAD Ta=22.5℃
2. HIGH AMBIENT BURN-IN: 1 HRS
I/P: 230VAC O/P: FULL LOAD Ta=44.9℃
TEST CONDITION
RESULT
ROOM AMBIENT HIGH AMBIENT
Ta=22.5℃
Ta=44.9℃
NO
Position
1
LF1
59.7℃
78.2℃
2
LF2
57.5℃
77.2℃
3
BD1
60.7℃
80.1℃
4
LF3
63.6℃
83.0℃
5
L2
65.3℃
84.3℃
6
C5
65.9℃
85.2℃
7
D1
69.5℃
85.7℃
8
Q31
65.4℃
84.9℃
9
Q32
67.3℃
87.0℃
10
D30
77.8℃
97.8℃
11
C52
66.8℃
86.2℃
12
T1
75.2℃
94.7℃
13
RTH30
65.3℃
84.7℃
14
Q101
64.6℃
83.9℃
15
CASE
50.8℃
71.0℃
16
Q102
61.5℃
81.4℃
17
C109
64.5℃
84.3℃
18
U2
63.8℃
83.0℃
19
R56
67.2℃
84.5℃
20
R64
67.2℃
86.7℃
21
R58
70.4℃
90.2℃
22
LF101
58.7℃
79.3℃
NO DAMAGE
1 HOUR ( MIN )
I/P: 230 VAC
O/P:126﹪LOAD
Ta:25℃
TEST:OK
LOW TEMPERATURE
TURN ON TEST
TURN ON AFTER 2 HOUR
I/P: 264VAC/100VAC
O/P: 100 ﹪LOAD
Ta=-30℃
TEST:OK
HIGH HUMIDITY
HIGH TEMPERATURE
HIGH VOLTAGE
TURN ON TEST
AFTER 12 HOURS
IN CHAMBER ON
CONTROL 40℃
I/P: 272 VAC
O/P:FULL LOAD
Ta=40℃
TEST:OK
NO DAMAGE
HUMIDITY= 95 %R.H
OVER LOAD BURN-IN TEST
TEMPERATURE
COEFFICIENT
+0.03%/℃(0~40℃)
VERDICT
I/P: 230 VAC
O/P:FULL LOAD
P
P
P
P
+0.012%/℃(0~40℃)
P
Model:GST90A19-P1M
Test Report
6 / 7
GST90A
90W AC-DC High Reliability Industrial Adaptor
6
7
8
9
10
11
STORAGE TEMPERATURE TEST
THERMAL SHOCK TEST
VIBRATION TEST
CAPACITOR
LIFE CYCLE
MTBF
DMTBF/Accelerated Life Test
1.
2.
3.
4.
5.
Thermal shock Temperature: -40℃~ +85℃
Temperature change rate :25℃ / MIN
Dwell time low and high temperature : 30 MIN/EACH
Total test cycle:5 CYCLE
Input/Output condition: STATIC
TEST:OK
1.
2.
3.
4.
5.
Thermal shock Temperature: -30℃~ +70℃
Temperature change rate :25℃ / MIN
Dwell time low and high temperature : 30 MIN/EACH
Total test cycle:10 CYCLE
Input/Output condition: 230VAC/Full Load AC ON/OFF TEST
turn on 58sec;turn off 2sec
TEST:OK
1 Carton & 1 Set
(1) Waveform: Sine Wave
(2) Frequency:10~500Hz
(3) Sweep Time:12min/sweep cycle
(4) Acceleration:2G
(5) Test Time:60min in each axis (X.Y.Z)
(6) Ta:25℃
SUPPOSE C109
IS THE MOST CRITICAL COMPONENT
(1) I/P: 230VAC O/P:FULL LOAD Ta=25℃ LIFE TIME
(2) I/P: 230VAC O/P:FULL LOAD Ta=40℃ LIFE TIME
(3) I/P: 230VAC O/P:75% LOAD Ta=40℃ LIFE TIME
(4) I/P: 230VAC O/P:50% LOAD Ta=40℃ LIFE TIME
MIL-HDBK-217F
TOTAL FAILURE RATE:348.7KHRS
series
P
P
TEST:OK
P
(1)
(2)
(3)
(4)
171060 HRS
72452 HRS
127834 HRS
240196 HRS
P
P
Demonstration Mean Time Between Failure (Expected Life): Above 50,000 hours @ TA 50℃
TEST RESULT
TESTER
APPROVAL
PASS
FRANK
WANGDZ
2007/3/20
Model:GST90A19-P1M
P
A50-S014
Test Report
7 / 7