Test Report: HDP‐190 190W Dual Output PFC Function DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test Control Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C. Test RELIABILITY TEST ENVIRONMENT TEST HDP-190 series DESIGN VERIFY TEST OUTPUT FUNCTION TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RIPPLE & NOISE V1:100 mVp-p (Max ) I/P: 230VAC RESULT V1: 31 mVp-p (Max ) VERDICT V2:100 mVp-p (Max ) O/P:FULL LOAD V2: 46.8 mVp-p (Max ) Ta:25℃ 2 3 OUTPUT VOLTAGE CH1: 3.6 V ~4 V I/P: 230 VAC 3.405 V~ 4.1628 V/ 230 VAC ADJUST RANGE CH2: 2.5 V ~3 V I/P: 115 VAC 3.405 V~ 4.1628 V/115 VAC O/P:MIN LOAD 2.406 V~ 3.117 V/ 230 VAC Ta:25℃ 2.406 V~ 3.117 V/ 115 VAC P OUTPUT VOLTAGE V1:2 %~ -2 % (Max) I/P:100 VAC / 264 VAC V1: 0.4 %~ -0.4 % TOLERANCE V2:2 %~ -2 % (Max) O/P:FULL/ MIN V2: 0.4 %~ -0.4 % LOAD P Ta:25℃ 4 LINE REGULATION V1:0.5 %~ -0.5 % (Max) I/P:100VAC ~ 264 VAC V1: 0 %~ 0 % V2:0.5 %~ -0.5 % (Max) O/P:FULL LOAD V2: 0 %~ 0 % Ta:25℃ 5 LOAD REGULATION V1:2 %~ -2 % (Max) I/P: 230 VAC V1: 0.4 %~ -0.4 % V2:2 %~ -2 % (Max) O/P:FULL ~MIN LOAD V2: 0.4 %~ -0.4 % SET UP TIME P P Ta:25℃ 6 P 230VAC: 1000 ms (Max) I/P: 230 VAC 230VAC/ 511 ms 115VAC: 2500 ms(Max) I/P: 115 VAC 115VAC/ 1090 ms P O/P:FULL LOAD Ta:25℃ 7 RISE TIME 230VAC: 50 115VAC: 50 ms (Max) I/P: 230 VAC 230VAC/ 21 ms ms (Max) I/P: 115 VAC 115VAC/ 21 ms P O/P:FULL LOAD Ta:25℃ 8 HOLD UP TIME 230VAC: 16 ms (TYP) I/P: 230 VAC 230VAC/ 22 ms 115VAC: 16 ms (TYP) I/P: 115 VAC 115VAC/ 20 ms P O/P:FULL LOAD Ta:25℃ 9 OVER/UNDERSHOOT I/P: 230 VAC < +5% TEST: <5 % P O/P:FULL LOAD TEST Ta:25℃ 10 DYNAMIC LOAD V1: V2: 11 RATED POWER 760 560 192W mVp-p mVp-p MAX I/P: 230 VAC V1: mVp-p (1).O/P:FULL /Min LOAD 90%DUTY/ (1) 276 mVp-p 1KHZ (2).O/P:FULL /Min LOAD 50%DUTY/ (2) 366 V2: mVp-p 120HZ Ta:25℃ (1) 252 mVp-p I/P: 230 VAC P (2) 284 TEST:OK O/P:FULL LOAD P Ta:25℃ Model: HDP-190 Test Report 2 / 8 HDP-190 series INPUT FUNCTION TEST NO 1 TEST ITEM SPECIFICATION INPUT VOLTAGE RANGE TEST CONDITION 100VAC~264 VAC RESULT I/P:TESTING VERDICT 70V~264V O/P:FULL LOAD Ta:25℃ I/P: TEST: OK LOW-LINE-3V= 97 V P HIGH-LINE+15%=300 V O/P:FULL/MIN LOAD ON: 30 Sec . OFF: 30 Sec 10MIN ( AC POWER ON/OFF NO DAMAGE ) 2 INPUT FREQUENCY RANGE I/P:100 VAC ~ 264 VAC 47HZ ~63 HZ TEST: OK P O/P:FULL~MIN LOAD NO DAMAGE OSC Ta:25℃ 3 POWER FACTOR 0.94 / 230 VAC(TYP) 0.98 / 115 VAC(TYP) I/P: 230 VAC I/P: 115 VAC O/P:FULL LOAD PF= 0.948 / 230 VAC PF= 0.984 / 115 VAC 87.36 % P Ta:25℃ 4 EFFICIENCY I/P: 230 VAC 86% (TYP) P O/P:FULL LOAD Ta:25℃ 5 INPUT CURRENT 230V/ 1.1 A (TYP) I/P: 230 VAC I= 0.98 A/ 230 VAC 115V/ 2.7 A (TYP) I/P: 115 VAC I= 1.93 A/ 115 VAC O/P:FULL LOAD P Ta:25℃ 6 INRUSH CURRENT 230V/ 45 A (TYP) I/P: 230 VAC I= 27 A/ 230 VAC 115V/ 30 A(TYP) I/P: 115 VAC I= 23 A/ 115 VAC COLD START 7 LEAKAGE CURRENT < O/P:FULL LOAD P Ta:25℃ 2 mA / 240 VAC I/P: 264 VAC L-FG: 0.53 mA O/P:Min LOAD N-FG: 0.53 mA P Ta:25℃ Model: HDP-190 Test Report 3 / 8 HDP-190 series PROTECTION FUNCTION TEST NO 1 TEST ITEM OVER LOAD PROTECTION SPECIFICATION V1+V2:105 % ~ 150 % MAX OUTPUT POWER TEST CONDITION RESULT I/P: 230 VAC V1+V2: VERDICT I/P: 115 VAC 135%/ 230 VAC O/P:TESTING 135 %/ 115 VAC Ta:40℃ V2:125%~170% V1+V2 Hiccup Mode V2: RATED CURRENT P 140 %/ 230 VAC 140 %/ 115 VAC 2 OVER VOLTAGE PROTECTION CH1:4.37 V ~ 5.13 V I/P: 230 VAC V2 Hiccup Mode CH1: 4.73 V/ 230 VAC I/P: 115 VAC CH2:3.22V~3.78V O/P:MIN LOAD Ta:25℃ CH2: 4.76 V/ 115 VAC 3.35 V/ 230 VAC P 3.34 V/ 115 VAC Shut down Re- power ON 3 OVER TEMPERATURE PROTECTION SPEC: I/P: 230 VAC TSW1: 95 + 5℃ O.T.P. O/P:FULL LOAD O.T.P. Active Shut down Re-power ON NO DAMAGE P 4 SHORT PROTECTION SHORT EVERY OUTPUT I/P: 264 VAC NO DAMAGE 1 HOUR NO DAMAGE O/P:FULL LOAD Hiccup Mode P Ta:25℃ Model: HDP-190 Test Report 4 / 8 HDP-190 series COMPONENT STRESS TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT Power Transistor Q10 Rated: I/P:High-Line +3V = 267 V (1) 420 V ( D to S) or (C to E) Peak Voltage SiHP18N50C-E3 18A/500V O/P: (1)Full Load Turn on (2) 422 V (3) 416 V (2) Output Short VERDICT P (3)Full load continue Ta:25℃ 2 Diode Peak Voltage Q102 Rated: I/P:High-Line +3V = 267 V (1) 11 V AP98T03GP 200A/30V O/P: (1)Full Load Turn on (2) 8 V (3) 11.4 V (2)Output Short (3)Full load continue Q903 Rated: (1)Full Load Turn on (1) 5.12 V PSMN1R5-30YLC 100A/30V (2)Output Short (2) 400 mV (3)Full load continue (3) 4.56 V P Ta:25℃ 3 Input Capacitor Voltage C5 Rated: I/P:High-Line +3V = 267 V (1) 391.56 V 150u/400V 18*35.5 KMG O/P: (1)Full Load Turn on /Off (2) 391.90 V (2) Min load Turn on /Off (3) 398.65 V P (3)Full Load /Min load Change Ta:25℃ 4 Control IC Voltage Test U2 Rated: I/P:High-Line +3V = 267 V (1) 18.105 V PWM L6591 11.3V~22V O/P: (1)Full Load Turn on /Off (2) 18.054 V (2) Min load Turn on /Off (3) 18.130 V (3)Full Load /Min load Change U900 Rated: (1)Full Load Turn on /Off (1) 12.385 V TPS40140 4.5V~15V (2) Min load Turn on /Off (2) 12.383 V (3)Full Load /Min load (3) 12.383 V P Change Ta:25℃ 5 Power Transistor Q2 Rated: I/P:High-Line +3V = 267 V (1) 474 V ( D to S) or (C to E) Peak Voltage STP26NM60N 20A/600V O/P: (1)Full Load Turn on (2) 456 V (3) 426 V (2) Output Short P (3)Full load continue Ta:25℃ Model: HDP-190 Test Report 5 / 8 HDP-190 series SAFETY & E.M.C. TEST SAFETY TEST NO 1 TEST ITEM SPECIFICATION TEST CONDITION RESULT WITHSTAND VOLTAGE I/P-O/P: 3 KVAC/min I/P-O/P: 3.6 KVAC/min I/P-O/P: 5.94 mA I/P-FG: 1.5 KVAC/min I/P-FG: 1.8 KVAC/min I/P-FG: O/P-FG: 0.6 KVAC/min 4.87 mA O/P-FG: 0.5 KVAC/min O/P-FG: 5.38 mA Ta:25℃ 2 ISOLATION RESISTANCE GROUNDING CONTINUITY I/P-O/P:500VDC>100MΩ I/P-O/P: 500 VDC I/P-O/P: 30 GΩ I/P-FG: 500VDC>100MΩ I/P-FG: 500 VDC O/P-FG:500VDC>100MΩ O/P-FG: 500 VDC I/P-FG: 30 GΩ O/P-FG: 30 GΩ FG(PE) TO CHASSIS OR TRACE < 100 mΩ P NO DAMAGE Ta:25℃/70%RH 3 VERDICT P NO DAMAGE 40 A / 2min Ta:25℃ / 70%RH 5 mΩ P E.M.C TEST NO 1 2 TEST ITEM SPECIFICATION TEST CONDITION RESULT HARMONIC EN61000-3-2 I/P:240/230/220VAC/50HZ PASS CLASS A CLASS D O/P:100/% T a:25℃ EN55022 I/P: 230 VAC (50HZ) PASS CLASS B O/P:FULL/50% LOAD Test by certified Lab CONDUCTION VERDICT P P Ta:25℃ 3 RADIATION EN55022 I/P: 230 VAC (50HZ) PASS CLASS B O/P:FULL LOAD Test by certified Lab P Ta:25℃ 4 5 6 E.S.D E.F.T SURGE EN61000-4-2 I/P: 230 VAC/50HZ INDUSTRY AIR:8KV / Contact:4KV O/P:FULL LOAD EN61000-4-4 I/P: 230 VAC/50HZ INDUSTRY INPUT: 2KV O/P:FULL LOAD IEC61000-4-5 I/P: 230 VAC/50HZ INDUSTRY L-N :2KV O/P:FULL LOAD CRITERIA A P Ta:25℃ CRITERIA A P Ta:25℃ CRITERIA A P Ta:25℃ L,N-PE:4KV 7 Test by certified Lab & Test Report Prepare Model: HDP-190 Test Report 6 / 8 HDP-190 series RELIABILITY TEST ENVIRONMENT TEST NO 1 TEST ITEM SPECIFICATION TEMPERATURE RISE TEST MODEL:HPD-190 TEST CONDITION RESULT VERDICT 1. ROOM AMBIENT BURN-IN:1.5 HRS I/P: 230VAC O/P: FULL LOAD Ta=25.7 2. HIGH AMBIENT BURN-IN:5 ℃ HRS I/P: 230VAC O/P: FULL LOAD Ta= 43.8 ℃ 2 OVER LOAD BURN-IN TEST ROOM AMBIENT HIGH AMBIENT Ta= 25.7 ℃ Ta= 43.8 ℃ NO Position P/N 1 U1 PWM UCC28019ADR(G4) 64.3 75.3 2 U2 PWM L6591 SO16 65.4 74.2 3 LF1 TR894-R1 R-22x14x8B 14.6m 59.7 70.6 4 BD1 61.2 72.7 5 Q2 STP26NM60N 20A/600V 61.9 72.4 6 TSW2 60.4 71.7 7 C5 56.4 67.8 8 L1 COIL 95 ± 5℃ 150u/400V 105 18*35.5 KMG CK TF2379-R0 PQ-3220 65.1 76.6 9 Q10 SiHP18N50C-E3 18A/500V 60.7 72.2 10 D19 SFRD SBYV26C 1A/600V 58.2 67.7 11 C19 C/MPP 154/400V 5% 54.9 63.4 GLASS KBJ608G 12 C42 47u/35V L6Kh 5*11 ZLH 62.8 71.4 13 T1 COIL MT TF2380-R0 PQ-4025 96.4 106.1 14 C46 66.7 C203 83.9 95.2 16 L101 47u/50V L5Kh 6.3*11 YXF SMD C/MC 106/16V 10% X7R 1206 TR1007-R0 Ku092125 10.5u 56.4 15 95.8 106.8 17 L102 TR1008-R0 Ku092125 5.1u 95.6 107.2 18 Q102 AP98T03GP 200A/30V 86.2 97.0 19 Q103 77.5 86.7 20 C122 76.1 87.4 21 L901 79.8 89.8 22 Q901 78.7 88.7 23 C908 76.8 87.0 24 RTH4 AP98T03GP 200A/30V 4700u/6.3V UL10Kh 12.5*25 ZLH POWER INDUCTOR DM1210-R47 0.47uH PSMN1R5-30YLC 100A/30V LFPAK 47uF/6.3V 20% 7343(CD) NTC 5KΩ TTC3A502F39HEY 1% 78.6 90.2 NO DAMAGE I/P: 230 VAC 1 HOUR ( MIN ) O/P:123 P TEST:OK P ﹪LOAD Ta:25℃ 3 LOW TEMPERATURE TURN ON AFTER 2 HOUR I/P: 264VAC/100VAC Ta= 4 I/P:272 VAC HIGH VOLTAGE IN CHAMBER ON CONTROL 40 ℃ O/P:FULL LOAD TURN ON TEST NO DAMAGE HUMIDITY= HIGH TEMPERATURE 5 TEMPERATURE COEFFICIENT + 0.03%(0~50℃) P -35 ℃ AFTER 12 HOURS HIGH HUMIDITY TEST:OK O/P: 100 ﹪LOAD TURN ON TEST TEST:OK P Ta= 40 ℃ 95 %R.H I/P: 230 VAC + 0.027 %(0~50℃) O/P:FULL LOAD P Model: HDP-190 Test Report 7 / 8 HDP-190 series 6 STORAGE TEMPERATURE TEST OK 1. Thermal shock Temperature: -45℃~ +90℃ 2. Temperature change rate :25℃ / MIN 3. Dwell time low and high temperature : 30 MIN/EACH P 4. Total test cycle:5 CYCLE 5. Input/Output condition: STATIC 7 THERMAL SHOCK TEST OK 1. Thermal shock Temperature: -30℃~ +40℃ 2. Temperature change rate :25℃ / MIN 3. Dwell time low and high temperature : 30 MIN/EACH P 4. Total test cycle:10 CYCLE 5. Input/Output condition: 230VAC/Full Load AC ON/OFF TEST turn on 58sec;turn off 2sec 8 VIBRATION TEST TEST:OK 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:12min/sweep cycle P (4) Acceleration:2G (5) Test Time:60min in each axis (X.Y.Z) (6) Ta:25℃ 9 CAPACITOR LIFE CYCLE HDP-190:SUPPOSE C122 IS THE MOST CRITICAL COMPONENT (1) I/P: 230VAC O/P:FULL LOAD Ta= 25 ℃ LIFE TIME (1) 94760 HRS (2) I/P: 230VAC (2) 53714HRS 148718HRS 299506HRS 11 MTBF DMTBF/Accelerated Life Test DATE LIFE TIME Ta= 40 ℃ LIFE TIME (3) (4) I/P: 230VAC O/P:50% LOAD Ta= 40 ℃ MIL-HDBK-217F NOTICES2 PARTS COUNT TOTAL FAILURE RATE:111.3 KHRS LIFE TIME (4) (3) I/P: 230VAC 10 O/P:FULL LOAD Ta= 40 ℃ O/P:75% LOAD P P Demonstration Mean Time Between Failure (Expected Life): Above 30,000 hours @ TA 40℃ P SAMPLE TEST RESULT TESTER APPROVAL 2011/11/9 RD SAMPLE PASS SANFORD SU VINCENT TSENG 2011/11/21 PRODUCT SAMPLE PASS SANFORD SU VINCENT TSENG PASS SANFORD SU VINCENT TSENG 2011/12/21 PRODUCT SAMPLE 2009/08/04 Model: HDP-190 A50-F023 Test Report 8 / 8