DKA15 series

DKA15 series
DC-DC Module Type Regulated Dual Output Converter
Model : DKA15A-15
15W
V1 : +15V / 50~500mA
V2 : - 15V / 50~500mA
OUTPUT FUNCTION TEST
NO
1
2
3
4
TEST ITEM
VOLTAGE ACCURACY
RIPPLE & NOISE
LINE REGULATION
LOAD REGULATION
SPECICATION
TEST CONDITION
V1:-2%~+2% (Max)
I/P:12VDC
V2:-2%~+2% (Max)
O/P:50% LOAD
Ta:25℃
V1:60mVp-p (Max)
I/P:12VDC
V2:60mVp-p (Max)
O/P:FULL LOAD
Ta:25℃
V1:-0.2%~+0.2% (Max)
I/P:9VDC~18VDC
V2:-0.2%~+0.2% (Max)
O/P:FULL LOAD
Ta:25℃
V1:-0.5%~+0.5% (Max)
I/P:12VDC
V2:-0.5%~+0.5% (Max)
O/P:MIN~FULL LOAD
Ta:25℃
RESULT
V1:-0.6%
V2:-0.78%
V1:34mV
V2:38mV
V1:-0.04%~+0.04%
V2:-0.04%~+0.02%
V1:-0.03%~+0.03%
V2:-0.06%~+0.06%
VERDICT
P
P
P
P
INPUT FUNCTION TEST
NO
1
TEST ITEM
DC VOLTAGE RANGE
SPECICATION
9VDC~18VDC (Typ)
TEST CONDITION
O/P:FULL LOAD
Ta:25℃
2
EFFICIENCY
83% (Typ)
DC CURRENT
VERDICT
7.8V~18V
P
81.6%
P
I/P:12VDC
O/P:FULL LOAD
Ta:25℃
3
RESULT
I/P:TESTING
30mA (Typ) NO LOAD
I/P:12VDC
1600mA (Typ) FULL LOAD
O/P:NO LOAD ~ FULL LOAD
Ta:25℃
33.2mA / NO LOAD
1525mA / FULL LOAD
P
PROTECTION FUNCTION TEST
NO
1
2
TEST ITEM
OVER LOAD PROTECTION
SHORT PROTECTION
SPECICATION
110%~250% (Max)
TEST CONDITION
RESULT
I/P:12VDC
118%
O/P:TESTING
Ta:25℃
Hiccup Mode
SHORT EVERY OUTPUT
I/P:12VDC
NO DAMAGE
1 HOUR NO DAMAGE
O/P:FULL LOAD
Ta:25℃
Hiccup Mode
Reset Auto Recovery
Reset Auto Recovery
VERDICT
P
P
Model: DKA15A-15 Test Report
1 / 2
DKA15 series
DC-DC Module Type Regulated Dual Output Converter
ENVIRONMENT TEST
NO
1
TEST ITEM
TEMPERATURE RISE TEST
SPECICATION
TEST CONDITION
RESULT
VERDICT
1. ROOM AMBIENT BURN-IN:4HRS
I/P:12VDC
O/P:FULL LOAD Ta=26.9℃
2. HIGH AMBIENT BURN-IN:3HRS
I/P:12VDC
2
LOW TEMPERATURE
O/P:FULL LOAD Ta=63.7℃
Position
P/N
1
2
CASE
CENTER
57.9℃
87.7℃
TURN ON AFTER 3 HOURS
TURN ON TEST
I/P:12VDC
O/P: 100﹪LOAD
Ta= -25℃
P
TEST:OK
P
SAFETY TEST
TEST ITEM
NO
1
WITHSTAND VOLTAGE
SPECICATION
I/P-O/P:1KVDC/min
TEST CONDITION
I/P-O/P:1KVDC/min
Ta:25℃
RESULT
I/P-O/P:0.02mA
NO DAMAGE
2
ISOLATION RESISTANCE
I/P-O/P:500VDC>100MΩ
I/P-O/P:500VDC
Ta:25℃
I/P-O/P:>100MΩ
NO DAMAGE
DATE
SAMPLE
2008.1.10
STOCK
TEST RESULT
PASS
VERDICT
P
P
TESTER
APPROVAL
PETER
T.K.CHENG
Model: DKA15A-15 Test Report
2 / 2