GSM06U07-P1J

 Test Report : GSM06x07 AC‐DC Green Medical Adaptor  DESIGN VERIFY TEST
Output Function Test
Input Function Test
Protection Function Test
 SAFETY TEST
Safety Test
 RELIABILITY TEST
Other test
GSM06
series
RESULT
VERDICT
 DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO
1
TEST ITEM
RIPPLE & NOISE
SPECICATION
80mVp-p (Max)
TEST CONDITION
I/P:230VAC
O/P:FULL LOAD
Ta:25℃
2
VOLTAGE TOLERANCE
-5% ~ +5% (Max)
LINE REGULATION
-0.5% ~ +0.5% (Max)
LOAD REGULATION
-5% ~ +5% (Max)
SET UP TIME
1000mS
RISE TIME
50mS
HOLD UP TIME
P
-1.35% ~ +2.86%
P
873mS
P
39.9mS
P
16.1mS
P
I/P:230VAC
O/P:FULL LOAD
Ta:25℃
7
-0.46% ~ +0.10%
I/P:230VAC
O/P:FULL LOAD
Ta:25℃
6
P
I/P:230VAC
O/P:FULL ~MIN LOAD
Ta:25℃
5
-1.74% ~ +2.99%
I/P:90VAC ~264VAC
O/P:FULL LOAD
Ta:25℃
4
P
I/P:90VAC~264VAC
O/P:FULL~MIN. LOAD
Ta:25℃
3
34mVp-p
12mS (Min)
I/P:115VAC
O/P:FULL LOAD
Ta:25℃
INPUT FUNCTION TEST
NO
1
TEST ITEM
VOLTAGE RANGE
SPECICATION
90VAC ~ 264VAC
TEST CONDITION
O/P:FULL LOAD
Ta:25℃
2
3
4
5
FREQUENCY RANGE
EFFICIENCY
AVERAGE EFFICIENCY
AC CURRENT
P
TEST: OK
P
O/P:FULL LOAD
Ta:25℃
76.52%
P
I/P:115/230VAC
O/P:25%、50%、75%、100% LOAD
74.86% (115VAC)
Ta:25℃
74.89% (230VAC)
I/P: 100VAC ~ 240VAC
NO DAMAGE OSC
O/P:FULL~MIN LOAD
Ta:25℃
74% (Typ.)
I/P:230VAC
0.18A (Max)
NO LOAD POWER
CONSUMPTION
0.3W
P
I/P: 100VAC
O/P:FULL LOAD
Ta:25℃
6
VERDICT
70V ~ 264V
50HZ - 60HZ (Typ)
73.41% ( LEVEL Ⅴ)
RESULT
I/P:TESTING
0.150A
P
0.2W
P
I/P:230VAC
O/P: NO LOAD
Ta:25℃
Model: GSM06x07 Test Report
2 / 3
GSM06
7
8
INRUSH CURRENT
LEAKAGE CURRENT
< 30A
I/P:230VAC
COLD START
O/P:FULL LOAD
Ta:25℃
< 0.05mA
I/P:240VAC
O/P:Min LOAD
Ta:25℃
19.9A
series
P
L-FG: 0.02mA
N-FG: 0.02mA
P
PROTECTION FUNCTION TEST
NO
1
2
3
TEST ITEM
OVER LOAD PROTECTION
OVER VOLTAGE PROTECTION
SHORT PROTECTION
SPECICATION
>105%
110%~140%
TEST CONDITION
RESULT
I/P:230VAC
1.54A (193%)
O/P:TESTING
Ta:25℃
HICCUP MODE
RESET : AUTO RECOVER
VERDICT
P
I/P:230VAC
O/P:MIN LOAD
Ta:25℃
Clamp by ZENER diode
SHORT OUTPUT
I/P:264VAC
NO DAMAGE
1 HOUR NO DAMAGE
O/P:FULL LOAD
Ta:25℃
HICCUP MODE
RESET AUTO RECOVER
P
P
 SAFETY TEST
SAFETY TEST
NO
1
2
TEST ITEM
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SPECICATION
I/P-O/P:5656 VDC/min
I/P-O/P:500VDC>50MΩ
TEST CONDITION
RESULT
I/P-O/P:4242 VDC/min
Ta:25℃
I/P-O/P: 0.03uA
I/P-O/P:500 VDC
Ta:25℃
I/P-O/P>100MΩ
NO DAMAGE
NO DAMAGE
VERDICT
P
P
 RELIABILITY TEST
OTHER
NO
1
TEST ITEM
MTBF
SPECICATION
TEST CONDITION
RESULT
MIL-KDBK-217F NOTICES 2 PARTS COUNT
TOTAL FAILURE RATE:1.127
P
M.T.B.F:886925HRS
TEST RESULT
PASS
VERDICT
TESTER
APPROVAL
PETER
VINCENT
Model: GSM06x07 Test Report
3 / 3