Test Report : SKA60B-05

 Test Report : SKA60B‐05 60W DC‐DC Regulated Single Output Converter  DESIGN VERIFY TEST
Output Function Test
Input Function Test
Protection Function Test
Control Function Test
 SAFETY TEST
Safety Test
 RELIABILITY TEST
Environment Test
SKA60
series
 DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO
1
TEST ITEM
VOLTAGE ACCURACY
SPECICATION
-2%~+2% (Max)
TEST CONDITION
RIPPLE & NOISE
60mVp-p (Max)
Ta:25℃
LINE REGULATION
-0.5%~+0.5% (Max)
LOAD REGULATION
P
60 mV
P
-0.04 % ~ +0.04 %
P
-0.16 % ~ +0.10 %
P
I/P:18VDC~36VDC
O/P:FULL LOAD
Ta:25℃
4
0.4 %
I/P:24VDC
O/P:FULL LOAD
3
VERDICT
I/P:24VDC
O/P:FULL LOAD
Ta:25℃
2
RESULT
-0.5%~+0.5% (Max)
I/P:24VDC
O/P:MIN~FULL LOAD
Ta:25℃
INPUT FUNCTION TEST
NO
1
TEST ITEM
INPUT VOLTAGE RANGE
SPECICATION
18VDC~36VDC (Typ)
TEST CONDITION
EFFICIENCY
90.5% (Typ)
DC CURRENT
15.7 VDC ~ 36 VDC
P
91.04 %
P
I/P:24VDC
O/P:FULL LOAD
Ta:25℃
3
VERDICT
I/P:TESTING
O/P:FULL LOAD
Ta:25℃
2
RESULT
2775 mA / FULL LOAD (Max)
I/P:24VDC
120 mA / NO LOAD (Max)
O/P:NO / FULL LOAD
Ta:25℃
2757 mA / FULL LOAD
111 mA / NO LOAD
P
PROTECTION FUNCTION TEST
NO
1
2
TEST ITEM
OVER LOAD PROTECTION
INPUT OVER VOLTAGE
SPECICATION
110% ~ 160%
40 VDC ~ 50 VDC
PROTECTION
3
OUTPUT OVER VOLTAGE
7 VDC ~ 8.95 VDC
PROTECTION
4
SHORT PROTECTION
TEST CONDITION
RESULT
I/P:24VDC
139 %
O/P:TESTING
Ta:25℃
HICCUP MODE
I/P:TESTING
41.6 VDC
O/P:MIN LOAD
Ta:25℃
SHUTDOWN
AUTO-RECOVER
AUTO-RECOVER
VERDICT
P
P
I/P:24VDC
O/P:MIN LOAD
Ta:25℃
CLAMP BY TVS DIODE
SHORT EVERY OUTPUT
I/P:36VDC
NO DAMAGE
1 HOUR NO DAMAGE
O/P:FULL LOAD
Ta:25℃
HICCUP MODE
AUTO-RECOVER
P
P
Model: SKA60B-05 Test Report
2 / 3
SKA60
series
CONTROL FUNCTION TEST
NO
1
TEST ITEM
REMOTE CONTROL
SPECICATION
TEST CONDITION
Power on :
R.C >2.5Vdc or open
Power off :
RESULT
I/P:24VDC
Power on :
O/P:FULL LOAD
Ta:25℃
Power off :
R.C>1.2Vdc or Open
R.C <0.5Vdc or short (-Vin)
2
REMOTE SENSE
YES
TRIM
P
R.C<1.0Vdc or Short
I/P:24VDC
O/P:FULL LOAD
Ta:25℃
3
VERDICT
-10%~ +10% (Typ)
I/P:24VDC
Trim ~ +Vout Trim DOWN
O/P:FULL LOAD
Ta:25℃
Trim ~ -Vout
Trim UP
OK
P
Trim DOWN
-9.4%
Trim UP
+12.4%
P
Using 1M ohms VR
 SAFETY TEST
SAFETY TEST
NO
1
TEST ITEM
WITHSTAND VOLTAGE
SPECICATION
TEST CONDITION
I/P-O/P:1500 VDC/min
RESULT
I/P-O/P:1500 VDC/min
Ta:25℃
I/P-O/P: 0.02mA
NO DAMAGE
2
ISOLATION RESISTANCE
I/P-O/P:500VDC>100MΩ
I/P-O/P:500 VDC
Ta:25℃
I/P-O/P>100MΩ
NO DAMAGE
VERDICT
P
P
 RELIABILITY TEST
ENVIRONMENT TEST
NO
1
TEST ITEM
TEMPERATURE RISE TEST
SPECICATION
TEST CONDITION
RESULT
VERDICT
1. ROOM AMBIENT BURN-IN:4HRS
I/P:24VDC
O/P:FULL LOAD Ta=25℃
2. HIGH AMBIENT BURN-IN:268HRS
I/P:24VDC
O/P:FULL LOAD Ta=55℃
P
2
LOW TEMPERATURE TURN ON
NO
Position
P/N
1
2
1
CASE
CENTER
78.0℃
108.1℃
TURN ON AFTER 13 HOURS
TEST
I/P:24VDC
O/P: FULL LOAD
Ta= -40℃
DATE
SAMPLE
2012.4.6
RD SAMPLE
TEST RESULT
PASS
TEST:OK
P
TESTER
APPROVAL
PETER
VINCENT
Model: SKA60B-05 Test Report
3 / 3