SKA60 60W DC-DC Regulated Single Output Converter series Features : 2" 2" compact size 2:1 wide input range High efficiency up to 93% 1500VDC I/O isolation Built-in remote ON / OFF control Built-in remote sense Trimming output 10% Comply with CE / FCC without external components Protections: Short circuit / Overload / Input and output Over voltage Cooling by free air convection Six-sided shield metal case 100% burn-in test Low cost / High reliability Output 3.3V available 2 years warranty SPECIFICATION ORDER NO. SKA60A-05 SKA60B-05 SKA60C-05 SKA60A-12 SKA60B-12 SKA60C-12 SKA60A-15 SKA60B-15 SKA60C-15 DC VOLTAGE 5V 12V 15V CURRENT RANGE 1.2 ~ 12A 0.5 ~ 5A 0.4 ~ 4A RATED POWER 60W 80mVp-p 100mVp-p RIPPLE & NOISE (max.) Note.2 60mVp-p OUTPUT LINE REGULATION Note.3 0.5% LOAD REGULATION Note.4 0.5% 2.0% VOLTAGE ACCURACY 250KHz min. SWITCHING FREQUENCY 100uF 220uF EXTERNAL CAPACITANCE LOAD (max.) 1000uF EXTERNAL TRIM Adj. RANGE(Typ.) 10% A: 9 ~ 18VDC B: 18 ~ 36VDC C: 36 ~ 75VDC VOLTAGE RANGE 91% 90.5% 92% 92% EFFICIENCY (Typ.) DC CURRENT INPUT 92.5% 92% 92% 93% 92.5% Full load 5505mA 2775mA 1370mA 5445mA 2715mA 1370mA 5400mA 2690mA 1370mA No load 120mA 60mA 160mA 120mA 60mA 160mA 120mA 85mA 185mA FILTER Pi network REMOTE CONTROL PROTECTION Power ON : R.C ~ -Vin > 2.5VDC or open circuit ; Power OFF : R.C ~ -Vin < 0.5VDC or short Fuse recommended 110% ~ 160% rated output power OVER CURRENT PROTECTION SHORT CIRCUIT (Note. 5) OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed Input(Typ.) A: >20 ~ 25VDC B: >40 ~ 50VDC C: >80 ~ 100VDC input voltage Protection type : Shut down o/p voltage, recovers automatically after fault condition is removed Output(Typ.) 5Vo : 7V ~ 8.95V ; 12Vo : 15V ~ 19.2V ; 15Vo : 18V ~ 23.3V WORKING TEMP. -40 ~ +70 CASE TEMP. +100 Protection type : Clamp by TVS diode (Refer to "Derating Curve") max. 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -55 ~ +105 , 10 ~ 95% RH 0.03% / (0 ~ 50 ) TEMP. COEFFICIENT WORKING HUMIDITY OTHERS 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes I/P-O/P:1.5KVDC I/P-O/P: 100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 Class A, FCC part 15 Class A without external components Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A EMS IMMUNITY DIMENSION 50.8*50.8*11.0 mm or 2"*2"*0.43" inch (L*W*H) WEIGHT 67g Unit:mm(inch) 50.8 (2.00) 5.8 (0.23) 7.62 5.08 7.62 5.08 (0.3) (0.2) (0.3) (0.2) 45.7 (1.8) 50.8 (2.00) 4 56 11 (0.43) 5.08 (0.2) Pin No. Output 1 2 3 4 Pin No. Output 5 6 7 8 R.C -Vin +Vin -R.S +R.S +Vout -Vout TRIM External Output Trimming 2 -Vin +Vout 10.16 12.7 (0.4) (0.5) -Vout 1.0 50 6 1 7 (0.04 0.005) 1M LOAD VR -40 0 25 50 55 70 90 VR 3 +Vin TRIM 8 Ta ( UP NOTE 100 78 BOTTOM VIEW 3 2 Derating Curve Pin Configuration Mechanical Specification LOAD (%) VIBRATION WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION DOWN ) TRIMPOT 1.All parameters are specified at normal input, rated load, 25 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Line regulation is measured from low line to high line at rated load. 4.Load regulation is measured from 10% to 100% rated load. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds. File Name:SKA60-SPEC 2012-02-24