PLC-100 100W Single Output Switching Power Supply series ■ Features : Universal AC input / Full range High efficiency up to 88.5% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Built-in active PFC function Class 2 power unit Pass LPS 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting 2 years warranty F 110 M M SPECIFICATION MODEL DC VOLTAGE OUTPUT PLC-100-15 PLC-100-20 PLC-100-24 PLC-100-27 PLC-100-36 PLC-100-48 15V 20V 24V 27V 36V 48V 11.25 ~ 15V 15 ~ 20V 18 ~ 24V 20.25 ~ 27V 27 ~ 36V 36 ~ 48V 5A 4.8A 4A 3.55A 2.65A 2A Note.6 0 ~ 5A 0 ~ 5A 0 ~ 4.8A 0 ~ 4A 0 ~ 3.55A 0 ~ 2.65A 0 ~ 2A RATED POWER Note.6 60W 75W 96W 96W 95.85W 95.4W 96W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE(Vo ADJ) 10.2 ~ 12V 12.8 ~ 15V 17 ~ 20V 20.4 ~ 24V 23 ~ 27V 30.6 ~ 36V 40.8 ~ 48V CURRENT ADJ. RANGE(Io ADJ) 3.75 ~ 5A 3.75 ~ 5A 3.6 ~ 4.8A 3 ~ 4A 2.6 ~ 3.55A 2 ~ 2.65A 1.5 ~ 2A VOLTAGE TOLERANCE Note.3 ±3.0% ±3.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% LINE REGULATION ±1.0% LOAD REGULATION ±2.0% SETUP, RISE TIME 500ms, 80ms/230VAC 1200ms, 80ms/115VAC at full load 60ms/230VAC 16ms/115VAC at full load Note.5 90 ~ 264VAC 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve) TOTAL HARMONIC DISTORTION THD< 20% when output loading≧75% at 115VAC/230VAC input EFFICIENCY (Typ.) 83% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 12V:0.8A/115VAC 0.4A/230VAC 15V:0.9A/115VAC 0.45A/230VAC COLD START 40A(twidth=950μs measured at 50% Ipeak) at 230VAC MAX. No. of PSUs on 16A CIRCUIT BREAKER 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC OVER CURRENT (Typ.) Note.4 PROTECTION OVER VOLTAGE 88.5% 88.5% 88% 88% 20V ~ 48V:1.1A/115VAC 88.5% 0.55A/230VAC <0.75mA / 240VAC 95 ~ 102% Protection type : Constant current limiting, recovers automatically after fault condition is removed 13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 30 ~ 36V 39 ~ 48V 52 ~ 64V Protection type : Shut down and latch off o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover -30 ~ +50℃ (Refer to "Derating Curve") VIBRATION 20 ~ 95% RH non-condensing -40 ~ +80℃, 10 ~ 95% RH ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS Note.7 UL1310, TUV EN60950-1, EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), J61347-1, J61347-2-13 approved WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2,-3, Class C (≧70% load) ; EN61000-3-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level, (surge 4KV), criteria A MTBF 297.9Khrs min. MIL-HDBK-217F (25℃) 200.5*69.5*35mm (L*W*H) 0.52Kg; 25pcs/14Kg/0.65CUFT DIMENSION PACKING NOTE 85% WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT OTHERS 127 ~ 370VDC FREQUENCY RANGE LEAKAGE CURRENT EMC .. ( except for 48V ) CURRENT RANGE VOLTAGE RANGE SAFETY & ( for 48V only) 12V Note.6 5A HOLD UP TIME (Typ.) INPUT LPS PLC-100-12 CONSTANT CURRENT REGION Note.4 9 ~ 12V RATED CURRENT SELV 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to "DRIVING METHODS OF LED MODULE". 5. Derating may be needed under low input voltage. Please check the static characteristics for more details. 6. This is the maximum possible output current and power. Over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. File Name:PLC-100-SPEC 2015-05-28 PLC-100 100W Single Output Switching Power Supply Mechanical Specification Case No.981A series Unit:mm 200.5 20.2 6.26 69.5 T case 1 20.2 2 34.75 2-R2.5 2-R9.0 1 100.25 2 3 6.26 35 ※ T case: Max. Case Temperature. Terminal Pin No. Assignment (TB1) : SWITCHLAB MB310-75003 Pin No. 1 2 3 Terminal Pin No. Assignment (TB2) : SWITCHLAB MB310-75002 Assignment FG AC/N AC/L Pin No. 1 2 Assignment +V -V Fosc : 100KHz Block Diagram EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V O.L.P. FG O.L.P. PFC CONTROL DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE (℃) 60 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:PLC-100-SPEC 2015-05-28 100W Single Output Switching Power Supply PLC-100 series Power Factor Characteristic Constant Current Mode 1.00 0.98 0.96 0.94 PF 0.92 0.90 115V 0.88 230V 0.86 0.84 0.82 0.80 0.78 50% 60% 70% 80% 90% LOAD 100% (100W) EFFICIENCY vs LOAD (48V Model) PLC-100 series possess superior working efficiency that up to 88.5% can be reached in field applications. 92 90 88 86 EFFICIENCY (%) 84 82 80 115V 78 76 230V 74 72 70 68 66 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE There are two major kinds of LED drive method "direct drive" and "with LED driver". A typical LED power supply may either work in "constant voltage mode (CV) or constant current mode (CC)" to drive the LEDs. Mean Well's LED power supply with CV+ CC characteristic can be operated at both CV mode [with LED driver, at area (A)] and CC mode [direct drive, at area (B)]. In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. Vo(%) 100 (B) Constant Current area (A) Constant Voltage area Should there be any compatibility issues, please contact MEAN WELL. 75 (min.) (C) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:PLC-100-SPEC 2015-05-28