PLN-60 60W Single Output LED Power Supply series ■ Features : Universal AC input / Full range (up to 295VAC) High efficiency 89% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit with adjustable OCP level Fully isolated plastic case with IP64 level Built-in active PFC function Pass LPS Class 2 power unit 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications (Note.2) Suitable for dry / damp locations Compliance to worldwide safety regulations for lighting 2 years warranty F 110 M M SELV LPS ( for 48V only) ( except for 48V ) IP64 .. SPECIFICATION MODEL DC VOLTAGE PLN-60-12 PLN-60-15 PLN-60-20 PLN-60-24 PLN-60-27 PLN-60-36 PLN-60-48 12V 15V 20V 24V 27V 36V 48V 10.5 ~15V 14 ~ 20V 16.8 ~24V 18.9 ~27V 25.2 ~ 36V 33.6 ~ 48V CONSTANT CURRENT REGION Note.6 8.4 ~ 12V RATED CURRENT 5A 4A 3A 2.5A 2.3A 1.7A 1.3A CURRENT RANGE 0 ~ 5A 0 ~ 4A 0 ~ 3A 0 ~ 2.5A 0 ~ 2.3A 0 ~ 1.7A 0 ~ 1.3A RATED POWER 60W 60W 60W 60W 62.1W 61.2W 62.4W 2.4Vp-p 1.8Vp-p 2.7Vp-p 2.7Vp-p 3.6Vp-p 4.6Vp-p 14.5 ~ 16.2V 19.5 ~ 22V 24 ~ 26V 25 ~ 30V 32.5 ~ 39V 43.6 ~ 51.8V RIPPLE & NOISE (max.) Note.2 2Vp-p OUTPUT VOLTAGE ADJ. RANGE Note.5 11.5 ~ 13V Can be adjusted by internal potentiometer SVR1 CURRENT ADJ. RANGE Note.5 3% ~ -25%. Can be adjusted by internal potentiometer SVR2 VOLTAGE TOLERANCE Note.3 ±10% LINE REGULATION ±3.0% LOAD REGULATION ±5.0% 500ms / 230VAC 3000ms / 115VAC at full load SETUP TIME VOLTAGE RANGE INPUT Note.4 90 ~ 295VAC FREQUENCY RANGE 47 ~ 63Hz 127 ~ 417VDC POWER FACTOR (Typ.) PF>0.92/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve) TOTAL HARMONIC DISTORTION THD< 20% when output loading≧75% at 115VAC/230VAC input and output loading≧80% at 277VAC input EFFICIENCY (Typ.) 85% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.8A/115VAC 0.4A/230VAC 0.3A/277VAC COLD START 35A(twidth=45μs measured at 50% Ipeak) at 230VAC MAX. No. of PSUs on 16A CIRCUIT BREAKER 32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC LEAKAGE CURRENT OVER CURRENT SHORT CIRCUIT PROTECTION OVER VOLTAGE 86% 87.5% 87% 88% <0.75mA / 240VAC Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed. 13.8 ~ 16V 17.5 ~ 21V 23 ~ 28V 28 ~ 32V 31 ~ 35V WORKING TEMP. -30 ~ +50℃ (Refer to "Derating Curve") SAFETY STANDARDS 41 ~ 46V 20 ~ 95% RH non-condensing -40 ~ +80℃, 10 ~ 95% RH ±0.03%/℃ (0 ~ 50℃) 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes UL879, UL1310, UL8750, CSA C22.2 No. 207-M89(except for 48V), TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V), CSA C22.2 No. 250.0-08(except for 48V), IP64, J61347-1, J61347-2-13 approved ; design refer to UL60950-1 SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.75KVAC EMC I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (≧75% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE 54 ~ 60V Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down VIBRATION 89% 95 ~ 110% OVER TEMPERATURE WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 89% I/P-FG:2KVAC O/P-FG:0.5KVAC 497.8Khrs min. MIL-HDBK-217F (25℃) 181*61.5*35mm (L*W*H) 0.5Kg; 24pcs/13Kg/0.75CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB. 6. Please refer to "DRIVING METHODS OF LED MODULE". 7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers. 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. File Name:PLN-60-SPEC 2015-05-28 PLN-60 60W Single Output LED Power Supply Mechanical Specification Case No.960A series Unit:mm 181 21.25 6.26 AC/L(Brown) AC/N(Blue) FG (Green/Yellow) 300±20 30.75 2-R2.5 61.5 300±20 90.5 +V(Red) -V(Black) SVT 18AWG×2C T case 21.25 SVT 18AWG×3C 6.26 35 ※ T case: Max. Case Temperature. Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2 shown in the diagram. SVR1 SVR2 SVR1 Output voltage adjustment SVR2 Output current adjustment Block Diagram fosc : 90KHz(115VAC) 120KHz(230VAC) EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING FG +V -V DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.C.P. O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 70 50 LOAD (%) LOAD (%) 60 40 20 -30 -25 -5 0 15 30 40 AMBIENT TEMPERATURE (℃) 50 60 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 295 INPUT VOLTAGE (V) 60Hz File Name:PLN-60-SPEC 2015-05-28 PLN-60 60W Single Output LED Power Supply series Power Factor Characteristic PF Constant Current Mode 1 0 0 0 0 0 0 0 0 0 0 0 .0 .9 .9 .9 .9 .9 .8 .8 .8 .8 .8 .7 0 8 6 4 2 0 8 6 4 2 0 8 277V ac 230V ac 115V ac 50% 60% 70% 80% 90% 100% (60W) LOAD EFFICIENCY vs LOAD (48V Model) EFFICIENCY (%) PLN-60 series possess superior working efficiency that up to 89% can be reached in field applications. 92 88 84 80 76 72 68 64 60 56 52 48 44 40 277Vac 230Vac 115Vac 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs. In the constant current region, the highest voltage at the output of the driver depends on the configuration of the end systems. 100 Should there be any compatibility issues, please contact MEAN WELL. Vo(%) Constant Current area 70 (min.) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:PLN-60-SPEC 2015-05-28