60W Single Output Industrial DIN Rail Power Supply MDR-60 series ■ ‧ ‧ ‧ ‧ ‧ , ‧ ‧ ‧ ‧ ‧ .. SPECIFICATION MODEL OUTPUT MDR-60-5 MDR-60-12 MDR-60-24 MDR-60-48 DC VOLTAGE 5V 12V 24V 48V RATED CURRENT 10A 5A 2.5A 1.25A CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~ 2.5A 0 ~ 1.25A RATED POWER 50W 60W 60W 60W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 150mVp-p VOLTAGE ADJ. RANGE 12 ~ 15V 24 ~ 30V 200mVp-p 48 ~ 56V VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% LINE REGULATION ±1.0% ±1.0% ±1.0% ±1.0% LOAD REGULATION ±1.5% ±1.0% ±1.0% ±1.0% 88% 87% SETUP, RISE TIME INPUT 5 ~ 6V Note.5 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.8A/115VAC 1A/230VAC COLD START 30A/115VAC 60A/230VAC <1mA / 240VAC OVERLOAD PROTECTION OVER VOLTAGE FUNCTION DC OK SIGNAL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY SAFETY & TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE EMC ISOLATION RESISTANCE (Note 4) EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING NOTE 20ms/115VAC at full load 120 ~ 370VDC EFFICIENCY (Typ.) LEAKAGE CURRENT OTHERS 500ms, 30ms/115VAC at full load 86% 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6.25 ~ 7.25V 15.6 ~ 18V 31.2 ~ 36V 57.6 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover Relay contact rating(max.): 30V/1A resistive -20 ~ +70℃ (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85℃, 10 ~ 95% RH ±0.03%/℃ (0 ~ 50℃) Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 UL508, UL60950-1, TUV EN60950-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3 Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A 299.2K hrs min. MIL-HDBK-217F (25℃) 40*90*100mm (W*H*D) 0.33Kg; 42pcs/14.8Kg/0.82CUFT ℃ File Name:MDR-60-SPEC 2014-10-22 MDR-60 60W Single Output Industrial DIN Rail Power Supply Mechanical Specification Case No.962A 35 40 series Unit:mm 100 5 5 5 5 5 +V +V -V -V DC OK DC OK + 90 +V ADJ N L 7.5 7.5 Install DIN rail TS35/7.5 or TS35/15 Block Diagram fosc : 60KHz DC OK RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V O.C.P. DETECTION CIRCUIT FG CONTROL O.L.P. O.V.P. DC OK Relay Contact Contact Close PSU turns on / DC OK. Contact Open PSU turns off / DC Fail. Contact Ratings (max.) 30V/1A resistive load. Derating Curve Output Derating VS Input Voltage 100 100 12V,24V,48V 90 80 80 70 50 5V LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 45 55 AMBIENT TEMPERATURE (℃) 60 70 (VERTICAL) 60 50 40 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:MDR-60-SPEC 2013-10-22