HSP-300 series

HSP-300
300W Single Output with PFC Function
series
■ Features :
•Universal AC input / Full range
•Withstand 300VAC surge input for 5 seconds
•Built-in active PFC function
•Low leakage current<1mA
•Protections: Short circuit / Overload / Over voltage / Over temperature
•Cooling by free air convection
•Low profile:31mm
•Conformal coated
•LED indicator for power on
•Suitable for high efficiency moving sign applications
•3 years warranty
SPECIFICATION
HSP-300-2.8
HSP-300-4.2
HSP-300-5
DC VOLTAGE
2.8V
4.2V
5V
RATED CURRENT
CURRENT RANGE Note.5
60A
0 ~ 60A
60A
0 ~ 60A
60A
0 ~ 60A
252W
150mVp-p
3.6~4.4V
300W
150mVp-p
4.5~5.5V
±2.0%
±2.0%
±0.5%
±0.5%
MODEL
OUTPUT
RATED POWER(convection)
168W
RIPPLE & NOISE (max.) Note.2 110mVp-p
VOLTAGE ADJ. RANGE
2.5~3V
VOLTAGE TOLERANCE Note.3 ±2.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±1.0%
2000ms, 100ms/230VAC
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
8ms/230VAC
Note.4 180 ~ 264VAC
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
47 ~ 63Hz
PF≥0.93/230VAC
±1.0%
3000ms, 100ms/115VAC at full load
8ms/115VAC at full load
254 ~ 370VDC or 90~135VAC
±1.0%
127~190VDC
PF ≥0.98/115VAC at full load
87%
85%
80%
2.8A/115VAC
1.4A/230VAC
Cold start 30A/115VAC 60A/230VAC
3.9A/115VAC
1.95A/230VAC
4.7A/115VAC
2.35A/230VAC
<1mA / 240VAC
105~150% rated output power
OVERLOAD
PROTECTION
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
4.6 ~ 5.4V
3.22 ~ 3.78V
5.7 ~ 7.0V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after fault condition is removed
-30 ~ +70℃(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 60℃)
TEMP. COEFFICIENT
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
VIBRATION
SAFETY &
EMC
(Note 5)
SAFETY STANDARDS
WITHSTAND VOLTAGE
UL60950-1,EN60950-1,CCC GB4943 approved
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
Compliance to EN55022 (CISPR22),GB9254,Class B, EN61000-3-2,-3,GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV), criteria A
EMC IMMUNITY
OTHERS
NOTE
I/P-O/P:3.0KVAC
I/P-FG:2.0KVAC
O/P-FG:0.5KVAC
MIL-HDBK-217F (25℃)
MTBF
263.2K hrs min.
DIMENSION
PACKING
210*81*31mm (L*W*H)
0.8kg; 15pcs/ 12.1kg/ 0.7CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Please refer to “Static Characteristics".
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:HSP-300-SPEC 2015-03-30
HSP-300
300W Single Output with PFC Function
Mechanical Specification
CASE NO.: 233B
series
Unit:mm
210
204
3
9
ADJ
1
63
81
TB1
3
2
2
3
1
4
31
4*ψ4.2
AC Input Terminal(TB1) pin NO. Assignment
Pin No.
1
2
3
Assignment
AC/L
AC/N
DC Output Terminal pin NO. Assignment
Terminal
Pin No.
1,2
3,4
DG28C-B-03P-13-00AH
Assignment
+V
-V
Terminal
NEL-400-02P
Block Diagram
EMI
FILTER
I/P
BRIDGE
RECTIFIERS
APFC
CONTROLLER
POWER
SWITCHING
SYNCHRONOUS
RECTIFIERS
& FILTER
+V
-V
O.T.P.
FG
O.L.P.
DETECTION
CIRCUIT
PWM
CONVERTER
O.V.P.
Derating Curve
Static Characteristics
180~264VAC
60
60
90~135VAC
50
50
30
Io(A)
Io(A)
40
40
35
30
25
20
10
10
-30
20
0
10
20
30
40 45 50
AMBIENT TEMPERATURE (℃)
60
70 (HORIZONTAL)
90
100
120 135
160
170
180
220
240
264
INPUT VOLTAGE (V) 60Hz
File Name:HSP-300-SPEC 2015-03-30
HSP-300
300W Single Output Switching Power Supply
series
Installation
1.Operate with additional aluminum plate
In order to meet the“Derating Curve”and the “Static Characteristics” ,HSP-300 series must be installed onto an aluminum plate(or the cabinet of the same size)
on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and
smooth surface (or coated with thermal grease), and HSP-300 series must be firmly mounted at the center of the aluminum plate.
Unit:mm
M3*4
3
450
450
5cm
5cm
5cm
2.For heat dissipation, at least 5cm installation distance around the PSU should be kept, shown as below:
5cm
5cm
File Name:HSP-300-SPEC 2015-03-30