MEANWELL AD-55

55W Single Output with Battery Charger(UPS Function)
AD-55
series
Features :
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Battery low protections
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 45KHz
2 years warranty
SPECIFICATION
AD-55A
MODEL
OUTPUT
INPUT
AD-55B
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
13.8V
13.4V
27.6V
26.5V
RATED CURRENT
3.5A
0.23A
1.8A
0.16A
CURRENT RANGE
0 ~ 4A
--------
0 ~ 2A
--------
RATED POWER
51.38W
53.92W
RIPPLE & NOISE (max.) Note.2 100mVp-p
--------
100mVp-p
--------
--------
CH1: 24 ~ 29V
1.0%
--------
VOLTAGE ADJ. RANGE
CH1: 12 ~ 14.5V
VOLTAGE TOLERANCE Note.3 1.0%
LINE REGULATION
0.5%
--------
0.5%
--------
LOAD REGULATION
0.5%
--------
0.5%
--------
SETUP, RISE TIME
800ms, 50ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
80ms/230VAC
88 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
1600ms, 50ms/115VAC at full load
16ms/115VAC at full load
124 ~ 370VDC
EFFICIENCY (Typ.)
71%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.6A/115VAC
1A/230VAC
COLD START 20A/115VAC
40A/230VAC
74%
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:14.49 ~ 18.63V
CH1:28.98 ~ 37.26V
PROTECTION
OVER VOLTAGE
FUNCTION
Protection type : Hiccup mode, recovers automatically after fault condition is removed
AC fail CN1 PIN2
DC ALARM SIGNAL(OPTIONAL) Battery low under charge voltage 82.5% 2% CN1 PIN1
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
SAFETY STANDARDS
WITHSTAND VOLTAGE
Normal 0.8V max. Abnormal 5V 0.5V
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 ) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
ISOLATION RESISTANCE
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
/ 70% RH
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
304.3K hrs min. MIL-HDBK-217F (25 )
DIMENSION
PACKING
159*97*38mm (L*W*H)
0.5Kg; 24pcs/12.6Kg/0.75CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:AD-55-SPEC 2008-10-08
AD-55
55W Single Output with Battery Charger(UPS Function)
Mechanical Specification
Case No. 901
4.5
series
Unit:mm
3.5
7
152.5
1
65
3
84.5
4
5
2-M
6.5
6
97
8.25
2
3
7
8
3.5
4.5
78
24
159
150
6.5
22
Pin No.
Pin No.
Assignment
1
5
AC/L
2
6
AC/N
3
7
FG
4
8
DC OUTPUT COM
38
M3
3.5
28.5
9
3.5
3-
18
18.5
9
Terminal Pin No. Assignment :
Assignment
DC OUTPUT +V
BAT. +
BAT.-/COM
NC
117
fosc : 45KHz
Block Diagram
BAT. CHARGER
&
BACK UP
RECTIFIERS
&
FILTER
EMI
FILTER
I/P
B+
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
COM/B-
FG
O.L.P.
PWM
CONTROL
Derating Curve
DETECTION
CIRCUIT
Static Characteristics (A)
Ta=25
100
OUTPUT VOLTAGE (V)
With 18.2CFM min.(10cm)
80
70
LOAD (%)
60
50
NO FAN
40
20
-10
300
+13.8V
0
10
20
30
40
50
AMBIENT TEMPERATURE ( )
60
(HORIZONTAL)
13
250
12
200
11
150
10
100
9
50
+13.8V
8
60
80
100
120
140
160
180
200
220
240
25
OUTPUT RIPPLE (mVp-p)
14
260
INPUT VOLTAGE (V) 60Hz
File Name:AD-55-SPEC 2008-10-08