PPS-200 200W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function High efficiency up to 90% (typ) Protections: Short circuit / Overload / Over voltage / Over temperature PWM control and regulated High power density 9.78W/inch3 5"x3" compact size Built-in remote sense function ZVS technology to reduce power dissipation Free air convection for 150W and 200W with 20.5 CFM forced air 3 years warranty SPECIFICATION MODEL PPS-200-5 PPS-200-12 PPS-200-15 PPS-200-24 PPS-200-27 PPS-200-48 DC VOLTAGE 5V 12V 15V 24V 27V 48V RATED CURRENT 36A CURRENT RANGE (convection) 0 ~ 26A OUTPUT 7.4A 4.167A 0 ~ 5.56A 0 ~ 3.13A 0 ~ 16.6A 0 ~ 13.3A 0 ~ 8.3A 0 ~ 7.4A 0 ~ 4.167A 150W 150W 150W 150W 150.24W RATED POWER (20.5CFM FAN) 180W 199.2W 199.5W 199.2W 199.8W 200.016W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p VOLTAGE ADJ. RANGE 10.8 ~ 13.2V 3.0% 13.5 ~ 16.5V 3.0% 21.6 ~ 26.4V 2.0% 24.3 ~ 30V 2.0% 43.2 ~ 52.8V 2.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 1200ms, 60ms/230VAC HOLD UP TIME (Typ.) 11ms/230VAC/115VAC at full load VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93/230VAC EFFICIENCY (Typ.) 86% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2.2A/115VAC 1.2A/230VAC COLD START 70A/230VAC LEAKAGE CURRENT <2mA / 240VAC OVERLOAD 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF NOTE 8.3A 0 ~ 6.25A RATED POWER (convection) 130W PROTECTION OVER VOLTAGE OTHERS 13.3A 0 ~ 10A CURRENT RANGE (20.5CFM FAN) 0 ~ 36A 4.5 ~ 5.5V VOLTAGE TOLERANCE Note.3 4.0% INPUT 16.6A 0 ~ 12.5A DIMENSION PACKING 2500ms, 60ms/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 89% 89% 13.8 ~ 16.2V 5.6 ~ 7.25V 17.25 ~ 20.25V 89% 27.6 ~ 32.4V 89% 90% 31.05 ~ 36.45V 57.6 ~ 67.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed 110 5 (TSW1) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 108.4Khrs min. MIL-HDBK-217F (25 127*76.2*34.6mm (L*W*H) 0.37Kg; 36pcs/14.3Kg/0.79CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Heat Sink HS1,HS2 can not be shorted. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. File Name:PPS-200-SPEC 2011-11-29 PPS-200 200W Single Output with PFC Function Mechanical Specification series Unit:mm 127 5 115.6 6.4 12 HS2 CN3 SVR1 1 2 3 4 5 6 7 8 76.2 64.8 HS1 1 2 3 CN1 CN5 AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 LED1 Assignment AC/L No Pin AC/N Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent 45 20.5CFM 3. 50mm Air flow direction DC Output Connector (CN5) : JST B8P-VH or equivalent Pin No. 1~4 5~8 FAN Assignment +V -V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 34.6 0.5 Remote Sense(CN3) : Molex 5045-02 or equivalent 3max. Pin No. 1 2 Assignment RSRS+ Mating Housing Terminal Molex 5051 or equivalent Molex 4809 or equivalent HS1,HS2 can not be shorted Block Diagram fosc : 100KHz EMI FILTER & RECTIFIERS I/P PFC CIRCUIT RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT FG O.L.P. PWM & PFC CONTROL Derating Curve O.V.P. Output Derating VS Input Voltage 100 125 90 With FAN 100 80 70 50 LOAD(%) LOAD (%) 70 Without FAN 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 115 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:PPS-200-SPEC 2011-11-29