Datasheet Fiber Driver™ Chassis The Optical Multi-Service Platform Hightlights Models with 1, 2, 3, 4, or 16 slots Flexible module hosting: no slot dependency Hot-swap support Management module support (except 1-slot models) - component and link status monitoring - command line and graphical administration - SNMP support with status traps Optional features on specific models (see ordering tables) - redundant power supplies (AC or DC pairs) - no power supply (passive solutions) - rack and wall mounting options - front cable management tray - blank slot covers Overview The Fiber Driver™ chassis is the foundation for deploying and managing the Fiber Driver multi-service mixed-media solutions. Chassis are available with one, two, three, four, and sixteen slots with power and mounting options depending on the model. The smaller models may be wall-mounted, the larger modules include 19” rack mount hardware, and all chassis can operate standalone on a tabletop mount. Besides module capacity, each Fiber Driver chassis model has some varied features. One-slot and two-slot chassis include an integrated internal AC or DC power supply with power ratings to support Fiber Driver one-slot or two-slot modules. Fiber Driver offering includes non-powered chassis. Some of these non-powered chassis have empty power supply bays that support the optional redundant power supplies. (See ordering information tables.) Non-powered chassis are designed to support passive networking solutions such as the Fiber Driver WDM modules in unmanaged applications. A Fiber Driver Network Management module may be installed in any multi-slot chassis to monitor system component parameters (temperature, fan status, and power supply) and network status. Some Fiber Driver devices may also be actively managed to affect operational features and parameters. The management module provides secure local serial access or remote Ethernet access to the entire Fiber Driver chassis system including the chassis itself, the modules, and even the individual ports Visit http://www.mrv.com or contact your nearest MRV representative for information on Fiber Driver or other products. 1 Datasheet Ordering Information REDUNDANT POWER SUPPLIES Model Description NC316-3RPSAC Redundant power supply for NC316BU-3/AC NC316-3RPSDC Redundant power supply for NC316BU-3/DC NC316BU-4SRPSAC Redundant power supply for NC316BU-4S/AC NC316BU-4SRPSDC Redundant power supply for NC316BU-4S/DC NC316-16RPSAC Redundant power supply for NC316BU-16/AC NC316-16RPSDC Redundant power supply for NC316BU-16/DC NC316BU-16/15RPSAC Redundant power supply for NC316BU-16/15AC NC316BU-16/15RPSDC Redundant power supply for NC316BU-16/15DC Ordering Information ACCESSORIES Model Description NC316MB-1 Wall mount bracket for NC316BU-1 NC316MB-2 Wall mount bracket for NC316BU-2 NC316RB23-3 Rack mount bracket for NC316BU-3/AC or -3/DC telco chassis; 23” NC316-4SBRACKET Rack mount bracket for 4-slot chassis; 19” NC316RB23-4S Rack mount bracket for NC316BU-4S/AC or -4S/DC telco chassis; 23” NC316-16BRACKET Rack mount bracket for 16-slot Chassis NC316RB23-16 Rack mount bracket for NC316BU-16/AC chassis, 23” NC316RB23-16/15 Rack mount bracket for NC316BU-16/15 chassis, 23” NC316BP-1 Blank panel, single-slot wide, for NC316BU NC316BP-4 Blank panel, four-slot wide, for NC316BU-16 NC316DCC DC power female connector (WAGO) NC316BU-16CMT Cable management tray for the NC316BU-16 chassis NC316MB-16 Wall mount bracket for NC316BU-16 NC316MB-16/15 Wall mount bracket for NC316BU-16/15 chassis NC316RB23-16/15 Rack mount bracket for NC316BU-16/15 chassis; 23” NC316-16DOOR 16BU chassis transponder protection door 19” rack mount NC316-16/15BRKT Rack Mount Bracket for NC316BU-16/15 chassis NC316-16/15DOOR 16BU chassis transponder protection door 19” rack mount and cable management tray for use with NC316BU-16/15 chassis 10900049-0001R DC power cord for BU-16/15 chassis 2015020-001R DC 10 ft. power cable for NC316-16/15RPSD Ordering Information CHASSIS Model Description Average Power (Per Slot) Physical Dimensions (HxWxD) Approx. Weight NC316BU-1/15AC One-slot, AC power 15 watts 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 1.0 kg (2.2 lbs) NC316BU-1/15DC One-slot, DC power 15 Watts 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 1.0 kg (2.2 lbs) NC316BU-1/15ACE One-slot, AC power (European version) 15 Watts 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 1.0 kg (2.2 lbs) NC316BU-1/15NP One-slot, no power supply (passive application only) N/A 38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”) 0.9 kg (2.0 lbs) 2 Datasheet CHASSIS (Continued) Description Average Power (Per Slot) Physical Dimensions (HxWxD) Weight NC316BU-2/15AC Two-slot, AC power 15 Watts 65 mm x 159 mm x 197 mm (2.56” x 6.26” x 7.75”) 1.4 kg (3.1 lbs) NC316BU-2/15DC Two-slot, DC power 15 Watts 65 mm x 159 mm x 197 mm (2.56” x 6.26” x 7.75”) 1.4 kg (3.1 lbs) NC316BU-3/AC Three-slot Telco, for 19” rack, AC power 15 Watts 44 mm x 439 mm x 203 mm (1.73” x 17.28” x 7.99”) 3.0 kg (6.6 lbs) NC316BU-3/DC Three-slot Telco, for 19” rack, DC power 15 Watts 44 mm x 439 mm x 203 mm (1.73” x 17.28” x 7.99”) 3.0 kg (6.6 lbs) NC316BU-3V/AC Three-slot, vertical stack, table mount, AC power 15 Watts 103 mm x 202 mm x 217 mm (4.05” x 7.95” x 8.54”) 2.5 kg (5.5 lbs) NC316BU-3V/DC Three-slot, vertical stack, table mount DC power 15 Watts 103 mm x 202 mm x 217 mm (4.05” x 7.95” x 8.54”) 2.5 kg (5.5 lbs) NC316BU-4S/AC Four-slot, for 19” rack, AC power 15 Watts 44 mm x 439 mm x 305 mm (1.73” x 17.28” x 12.00”) 4.5 kg (9.9 lbs) NC316BU-4S/DC Four-slot, for 19” rack, DC power 15 Watts 44 mm x 439 mm x 305 mm (1.73” x 17.28” x 12.00”) 4.5 kg (9.9 lbs) NC316BU-4S/NP Four-slot, two empty power supply bays N/A 44 mm x 439 mm x 305 mm (1.73” x 17.28” x 12.00”) 4.0 kg (8.8 lbs) Non-managed, non-powered four-slot chassis for passive Mux/Demux modules N/A 44 mm x 441 mm x 286 mm (1.73” x 17.36” x 11.26”) 4.5 kg (9.9 lbs) NC316BU-16/AC Sixteen-slot, for 19” rack, AC power 10 Watts 110 mm x 439 mm x 408 mm (4.33” x 17.28” x 16.06”) 8.8 kg (19.4 lbs) NC316BU-16/DC Sixteen-slot, for 19” rack, DC power 10 Watts 110 mm x 439 mm x 408 mm (4.33” x 17.28” x 16.06”) 8.7 kg (19.2 lbs) NC316BU-16/NP Sixteen-slot, for 19” rack, two empty power bays N/A (10-Watt option) 110 mm x 439 mm x 408 mm (4.33” x 17.28” x 16.06”) 7 kg (15.4 lbs) NC316BU-16/15AC Sixteen-slot, for 19” rack, AC power 15 Watts 132 mm x 439 mm x 359 mm (5.2” x 17.28” x 14.13”) 9.7 kg (21.4 lbs) NC316BU-16/15DC Sixteen-slot, for 19” rack, DC power 15 Watts 132 mm x 439 mm x 359 mm (5.2” x 17.28” x 14.13”) 9.4 kg (20.7 lbs) NC316BU-16/15NP Sixteen-slot, for 19” rack, two empty power bays N/A (15-Watt option) 132 mm x 439 mm x 359 mm (5.2” x 17.28” x 14.13”) 7.2 kg (15.8 lbs) Ordering Information Model NC316BU4PMC/NP Power Supply Specifications Nominal Input Range (VAC) Input Range (VDC)* Nameplate Rating (Amps) Operating Temperature Storage Temperature Relative Humidity NC316BU-1/15AC 100 - 240 @ 50/60 Hz - 0.3 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-1/15DC - - 40.5 to - 57 0.5 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-1/15ACE 100 - 240 @ 50/60 Hz - 0.3 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing Model * Compliant with ANSI T1.315-2001 (R 2006) standard 3 Datasheet Power Supply Specifications (Continued) Nominal Input Range (VAC) Input Range (VDC)* Nameplate Rating (Amps) Operating Temperature Storage Temperature Relative Humidity NC316BU-2/15AC 100 - 240 @ 50/60 Hz - 0.4 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-2/15DC - - 40.5 to - 57 0.8 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-3RPSAC 100 - 240 @ 50/60 Hz - 1.6 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-3RPSDC - - 40.5 to - 57 2.0 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-4SRPSAC 100 - 240 @ 50/60 Hz - 1.8 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-4SRPSDC - - 40.5 to - 57 2.0 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-16RPSAC 100 - 240 @ 50/60 Hz - 2.0 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-16RPSDC - - 40.5 to - 57 5.0 or 6.5 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing NC316BU-16/15RPSAC 100 - 240 @ 50/60 Hz - 3.7 0 to +50°C (+32 to +122°F) -20 to +70°C (0 to +154°F) < 85% non condensing NC316BU-16/15RPSDC - - 40.5 to - 57 7.5 -35 to +60°C (-31 to +140°F) -35 to +70°C (-31 to +158°F) < 85% non condensing Model * Compliant with ANSI T1.315-2001 (R 2006) standard Regulatory Compliance: FCC Part 15 (Class A); IC (Class A); EMC Directive: Emission (Class A) and Immunity; LVD Directive: Electrical Safety; CE Marking; TUV CUE Mark (Canada, USA, EU); GOST (selected products); RoHS 2 Directive, WEEE Directive: Wheelie Bin Mark; ETSI, NEBS (selected products), C-Tick (selected products). Contact your sales representative for details. MRV operates Worldwide sales and service offices across four continents. Contact us at [email protected] MRV Communications Corporate Headquarters 300 Apollo Drive Chelmsford, MA 01824 http://www.mrv.com All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information. MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders. MRV-FD-CHASS-111312 1398005-001 Rev. D5 Copyright ©2012 MRV Communications, Inc. All Rights Reserved.