MRV NC316BU-16-DC

Media Converters
Repeaters and Optimizers
Datasheet
FD
Fiber Driver® Chassis
Features
Models with 1, 2, 3, 4, or 16 slots
Rack mounting options ¹
Wall mounting options ²
Module flexibility; no slot dependency within a chassis
Hot-swap support
Management module compatibility ³
- fan status
- power supply status
- temperature status
- high and low temperature limits
- SNMP traps to report faults
Overview
The Fiber Driver® chassis is the foundation for deploying and managing
the Fiber Driver media module product family. Chassis are available with
one, two, three, four, and sixteen slots.
AC or DC redundant power supply pairs
Optional front cable management tray for NC316BU-16
chassis
The three-slot (NC316BU-3), four-slot (NC316BU-4 and NC316BU-4S),
sixteen-slot (NC316BU-16) and sixteen-slot Telco (NC316BU-16T) chassis
can be equipped with redundant, hot-swappable AC or DC internal
power supplies. The two-slot NC316BU-2 and one-slot NC316BU-1 come
with a single AC or DC internal power supply.
The NC316BU-1/NP and NC316BU4PMC/NP chassis are designed to
host fully passive modules such as the Fiber Driver Splitter/Combiner.
Because fully passive solutions require no external power source, these
chassis include no power supply.
ONE-SLOT CHASSIS
¹ three-slot, four-slot, and sixteen-slot models
² one-slot and two-slot models
³ two-slot, three-slot, four-slot, and sixteen-slot
chassis models
SIXTEEN-SLOT CHASSIS
THREE-SLOT CHASSIS
FOUR-SLOT CHASSIS
TWO-SLOT CHASSIS
SIXTEEN-SLOT TELCO 23” CHASSIS
[email protected]
Media Converters
Repeaters and Optimizers
Chassis with two, three, four and sixteen slots can
accommodate a network management module.
EM316NM and EM316LNXNM-OT provide monitoring of
system temperature, fan status, and power supply.
The one-slot chassis is suitable for unmanaged use in
standalone applications. The NC316BU-2 is designed for
single-module managed and two-module unmanaged
standalone applications.
The NC316BU-4, NC316BU-4S, and NC316BU-16 mount in
19” racks. The NC316BU-3 and NC316BU-16T, have reduced
depth form-factors and front-loaded power supplies for
Telco installations. These models mount in 23” racks, and
the NC316BU-3 can also mount in 19” racks.
Contact your nearest MRV representative for information
on Fiber Driver or other products.
Ordering Information
REDUNDANT POWER SUPPLIES
Model
Description
NC316-3RPSAC
Redundant Power Supply for NC316BU-3/AC
NC316-3RPSDC
Redundant Power Supply for NC316BU-3/DC
NC316-4RPSAC
Redundant Power Supply for NC316BU-4/AC
NC316-4RPSDC
Redundant Power Supply for NC316BU-4/DC
NC316BU-4SRPSAC
Redundant Power Supply for NC316BU-4S/AC
NC316BU-4SRPSDC
Redundant Power Supply for NC316BU-4S/DC
NC316-16RPSAC
Redundant Power Supply for NC316BU-16/AC
NC316-16RPSDC
Redundant Power Supply for NC316BU-16/DC
NC316-16T/DC
Redundant Power Supply for NC316BU-16T/DC
Ordering Information
ACCESSORIES
Model
Description
NC316RB23-3
Rack Mount Bracket for NC316BU-3/AC or -3/DC Telco Chassis; 23”
NC316RB23-4
Rack Mount Bracket for NC316BU-4/AC or -4/DC Telco Chassis; 23”
NC316-16BRACKET
Rack Mount Bracket for 16-slot Chassis
NC316RB23-16
Rack Mount Bracket for NC316BU-16/AC Chassis, 23”
NC316MB-1
Wall Mount Bracket for NC316BU-1
NC316MB-2
Wall Mount Bracket for NC316BU-2
NC316BP-1
Blank Panel, Single-Slot Wide, for NC316BU
NC316BP-4
Blank Panel, Four-Slot Wide, for NC316BU-16
NC316DCC
DC Power Female Connector (WAGO)
NC316BU-16CMT
Cable Management Tray for the NC316BU-16 Chassis
NC316-16DOOR
Cable Management Tray and transparent door for the NC316BU-16 Chassis
[email protected]
Media Converters
Repeaters and Optimizers
Ordering Information
CHASSIS
Model
Description
Physical Dimensions (hight x width x depth)
Weight
NC316BU-1/AC
One-slot, AC power
38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”)
1.0 kg (2.2 lbs)
NC316BU-1/DC
One-slot, DC power
38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”)
1.0 kg (2.2 lbs)
NC316BU-1/AC/EU
One-slot, VAC power (European version)
38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”)
1.0 kg (2.2 lbs)
NC316BU-1HP/AC
One-slot, AC power
38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”)
1.0 kg (2.2 lbs)
NC316BU-1HP/DC
One-slot, DC power
38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”)
1.0 kg (2.2 lbs)
NC316BU-1/NP
One-slot, no power supply (passive
application only)
38 mm x 159 mm x 199 mm (1.50” x 6.26” x 7.83”)
1.0 kg (2.2 lbs)
NC316BU-2/AC
Two-slot, AC power
65 mm x 159 mm x 197 mm (2.56” x 6.26” x 7.75”)
1.4 kg (3.1 lbs)
NC316BU-2/DC
Two-slot, DC power
65 mm x 159 mm x 197 mm (2.56” x 6.26” x 7.75”)
1.4 kg (3.1 lbs)
NC316BU-3/AC
Three-slot Telco, for19” rack, AC power
44 mm x 439 mm x 203 mm (1.73” x 17.28” x 7.99”)
3.1 kg (6.8 lbs)
NC316BU-3/DC
Three-slot Telco, for19” rack, DC power
44 mm x 439 mm x 203 mm (1.73” x 17.28” x 7.99”)
3.0 kg (6.6 lbs)
NC316BU-4/AC
Four-slot, for 19” rack, AC power
44 mm x 439 mm x 434 mm (1.73” x 17.28” x 17.09”)
7.7 kg (17.0 lbs)
NC316BU-4/DC
Four-slot, for 19” rack, DC power
44 mm x 439 mm x 434 mm (1.73” x 17.28” x 17.09”)
7.7 kg (17.0 lbs)
NC316BU-4S/AC
Four-slot, for 19” rack, AC power
44 mm x 439 mm x 305 mm (1.73” x 17.28” x 12.00”)
4.5 kg (9.9 lbs)
NC316BU-4S/DC
Four-slot, for 19” rack, DC power
44 mm x 439 mm x 305 mm (1.73” x 17.28” x 12.00”)
4.5 kg (9.9 lbs)
NC316BU4PMC/NP
Non-managed, non-powered four-slot
chassis for passive Mux/Demux modules
44 mm x 441 mm x 286 mm (1.73” x 17.36” x 11.26”)
4.3 kg (9.6 lbs)
NC316BU-16/AC
Sixteen-slot, for 19” rack, AC power
110 mm x 439 mm x 408 mm (4.33” x 17.28” x 16.06”)
8.8 kg (19.4 lbs)
NC316BU-16/DC
Sixteen-slot, for 19” rack, DC power
110 mm x 439 mm x 408 mm (4.33” x 17.28” x 16.06”)
8.7 kg (19.2 lbs)
NC316BU-16T/DC
Sixteen-slot Telco, for 23” rack, DC power
132 mm x 541 mm x 254 mm (5.20” x 21.30” x 10.00”)
8.2 kg (18.1 lbs)
[email protected]
Media Converters
Repeaters and Optimizers
Ordering Information
POWER SUPPLY SPECIFICATIONS
Model
Nominal Input
Range (VAC)
Input Range
(VDC)*
Maximum
Rating (Amps)
Operating
Temperature
Storage
Temperature
Relative
Humidity
NC316BU-1/AC
100 - 240 @ 50/60 Hz
-
0.3
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-1/DC
-
40.5 - 57
0.5
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-1/AC/EU
100 - 240 @ 50/60 Hz
-
0.3
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-1HP/AC
100 - 240 @ 50/60 Hz
-
0.3
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-1HP/DC
-
40.5 - 57
0.5
-40 to +65°C
(-40 to +149°F)
-45 to +75°C
(-49 to +167°F)
< 85%
non condensing
NC316BU-2/AC
100 - 240 @ 50/60 Hz
-
0.6
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-2/DC
-
40.5 - 57
1.0
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-3RPSAC
100 - 240 @ 50/60 Hz
-
1.6
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-3RPSDC
-
40.5 - 57
2.0
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-4RPSAC
100 - 240 @ 50/60 Hz
-
4.0
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-4RPSDC
-
40.5 - 57
2.0
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-4SRPSAC
100 - 240 @ 50/60 Hz
-
1.8
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-4SRPSDC
-
40.5 - 57
2.0
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-16RPSAC
100 - 240 @ 50/60 Hz
-
3.5
0 to +50°C
(+32 to +122°F)
-20 to +70°C
(0 to +154°F)
< 85%
non condensing
NC316BU-16RPSDC
-
40.5 - 57
5.0 or 6.5
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
NC316BU-16T/DC
-
40.5 - 57
5.0
-35 to +60°C
(-31 to +140°F)
-35 to +70°C
(-31 to +158°F)
< 85%
non condensing
* Compliant with ANSI TI.315-1994 standard
Regulatory Compliance: FCC Part 15 (Class A); IC (Class A); EMC Directive: Emission (Class A) and Immunity; LVD Directive: Electrical Safety; CE Marking;
TUV CUE Mark (Canada, USA, EU); GOST (selected products); RoHS Directive, WEEE Directive: Wheelie Bin Mark; ETSI, NEBS (selected products), C-Tick
(selected products). Contact your sales representative for details.
MRV has more than 50 offices throughout the world. Addresses, phone numbers, and fax numbers are listed at www.mrv.com.
Please e-mail us at [email protected] or call us for assistance.
MRV (West Coast USA)
20415 Nordhoff St.
Chatsworth, CA 91311
800-338-5316
818-773-0900
MRV (East Coast USA)
295 Foster St.
Littleton, MA 01460
800-338-5316
978-952-4700
MRV (International)
Business Park Moerfelden
Waldeckerstrasse 13
64546 Moerfelden-Walldorf
Germany
Tel. (49) 6105/2070
Fax. (49) 6105/207-100
All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness
thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information. MRV Communications and the MRV Communications
logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders.
MRV-FD-CHASS-120506
1398005-001 Rev. B
Copyright ©2006 MRV Communications, Inc. All Rights Reserved.