Optical Communications Systems™ Datasheet Passive DWDM Components Highlights Passive MUX/DeMUX - 8, 16, or 32 channels Passive Optical Add/Drop (OADM) - 1, 2, 4 or 8 channels DWDM C-Band, 100GHz ITU Grid (0.8nm spacing) Transparent operation - protocol and topology independent Secure physical separation between data channels Low insertion loss Power required only for managed applications and LEDs High port density EM316DWMUX16 EM316DWMUX32 Overview The Fiber Driver DWDM Passive MUX/DeMUX and OADM modules deliver the benefits of a Dense Wave Division Multiplexer in a fully passive solution. With matching MUX/DeMUX units placed at each end of an optical link, up to 32 data channels can be combined and transmitted over a single-mode fiber trunk. The passive OADM modules can add or drop up to 8 data channels at any point along the trunk. Because they operate independent of protocol and topology, these passive components remain transparent to both the network and the end user. With plug-n-play setup and a design that minimizes budget loss, they can readily and seamlessly integrate into an existing environment. Their small form factor and no power requirement means they can be placed virtually anywhere. Contact your MRV Communications representative for additional information on Fiber Driver or any MRV product, including pricing and availability. Physical Specifications Operating Temperature -5°C to 50°C (23°F to 122°F) Storage Temperature -55°C to 85°C (-67°F to 185°F) Relative Humidity 85% maximum, non-condensing Storage Humidity 5% to 95%, non-condensing Physical Dimensions: Approximate Weight: Regulatory Compliance One-Slot Module 25 mm x 90 mm x 170 mm deep (1” x 3.56” x 6.67” deep) Two-Slot Module 50 mm x 90 mm x 170 mm deep (2” x 3.56” x 6.67” deep) One-Slot Module 0.8 kg (1.8 lb) Two-Slot Module 1.4 kg (3.1 lb) FCC Part 15 (Class A); IC (Class A); EMC Directive: Emission (Class A) and Immunity; RoHS Directive; China RoHS; WEEE Directive * If operated in a non-powered chassis, temp range is -5º C to 70º C (23º F to 158º F) 1 Optical Communications Systems™ Datasheet PASSIVE DWDM MUX/DEMUX Model Description Connectors Ports/Link Wavelengths Ports & Link (nm) Max. Insertion Loss (dB) Max. Link Insertion Loss per Pair (dB) Adjacent Ch. Isolation (dB) Non Adj. Ch. Isolation (dB) Ordering Information EM316DWMX8 One Slot, passive 8-Ch. DWDM MUX. Channels 31 - 38 (Red) MU (x8) / SC 100 GHz ITU Grid, C-Band 3.0 4.3 ≥25 ≥40 EM316DWDMX8 One Slot, passive 8-Ch. DWDM DeMUX. Channels 31 - 38 (Red) MU (x8) / SC 100 GHz ITU Grid, C-Band 3.0 4.3 ≥25 ≥40 EM316DWMX8-R1 One Slot, passive 8-Ch. DWDM MUX. Channels 21 - 28 (Red) MU (x8) / SC 100 GHz ITU Grid, C-Band 3.4 4.7 ≥25 ≥40 EM316DWDMX8-R1 One Slot, passive 8-Ch. DWDM DeMUX. Channels 21 - 28 (Red) MU (x8) / SC 100 GHz ITU Grid, C-Band 3.4 4.7 ≥25 ≥40 EM316DWMX8-R2 One Slot, passive 8-Ch. DWDM MUX. Channels 29 - 36 (Red) MU (x8) / SC 100 GHz ITU Grid, C-Band 3.0 4.3 ≥25 ≥40 EM316DWDMX8-R2 One Slot, passive 8-Ch. DWDM DeMUX. Channels 29 - 36 (Red) MU (x8) / SC 100 GHz ITU Grid, C-Band 3.0 4.3 ≥25 ≥40 EM316DWMX8-R2B One Slot, passive 8-Ch. DWDM MUX. Channels 29 - 36 (Red) with band splitter. MU (x8) / DMU (x2) 100 GHz ITU Grid, C-Band 3.2 4.6 ≥25 ≥40 EM316DWDMX8-R2B One Slot, passive 8-Ch. DWDM DeMUX. Channels 29 - 36 (Red) with band splitter. MU (x8) / DMU (x2) 100 GHz ITU Grid, C-Band 3.2 4.6 ≥25 ≥40 EM316DWMX8-B1 One Slot, passive 8-Ch. DWDM MUX. Channels 43 - 50 (Blue). MU (x8) / SC 100 GHz ITU Grid, C-Band 3.2 4.6 ≥25 ≥40 EM316DWDMX8-B1 One Slot, passive 8-Ch. DWDM DeMUX. Channels 43 - 50 (Blue). MU (x8) / SC 100 GHz ITU Grid, C-Band 3.2 4.6 ≥25 ≥40 EM316DWMX8-B2B One Slot, passive 8-Ch. DWDM MUX. Channels 51 - 58 (Blue). MU (x8) / DMU (x2) 100 GHz ITU Grid, C-Band 3.2 4.6 ≥25 ≥40 EM316DWDMX8-B2B One Slot, passive 8-Ch. DWDM DeMUX. Channels 51 - 58 (Blue). MU (x8) / DMU (x2) 100 GHz ITU Grid, C-Band 3.2 4.6 ≥25 ≥40 EM316DWMX8-CW3 One Slot, passive 8-Ch. DWDM MUX. Channels 56 - 63 (Blue). MU (x8) / SC 100 GHz ITU Grid, C-Band 3.9 5.7 ≥25 ≥40 EM316DWDMX8-CW3 One Slot, passive 8-Ch. DWDM DeMUX. Channels 56 - 63 (Blue). MU (x8) / SC 100 GHz ITU Grid, C-Band 3.9 5.7 ≥25 ≥40 EM316DWMX8-CW5 One Slot, passive 8-Ch. DWDM MUX. Channels 31 - 38 (Red). MU (x8) / SC 100 GHz ITU Grid, C-Band 3.0 4.3 ≥25 ≥40 EM316DWDMX8-CW5 One Slot, passive 8-Ch. DWDM DeMUX. Channels 31 - 38 (Red). MU (x8) / SC 100 GHz ITU Grid, C-Band 3.0 4.3 ≥25 ≥40 EM316DWMUX16-R One Slot, passive 16-Ch. DWDM MUX. Channels 21 - 36 (Red). MU (x16) / SC 100 GHz ITU Grid, C-Band 4.5 7 ≥25 ≥40 EM316DWDMX16-R One Slot, passive 16-Ch. DWDM DeMUX. Channels 21 - 36 (Red). MU (x16) / SC 100 GHz ITU Grid, C-Band 4.5 7 ≥25 ≥40 EM316DWMUX16-B One Slot, passive 16-Ch. DWDM MUX. Channels 43 - 58 (Blue). MU (x16) / SC 100 GHz ITU Grid, C-Band 4.5 7 ≥25 ≥40 EM316DWDMX16-B One Slot, passive 16-Ch. DWDM DeMUX. Channels 43 - 58 (Blue). MU (x16) / SC 100 GHz ITU Grid, C-Band 4.5 7 ≥25 ≥40 EM316DWMUX16-BE One Slot, passive 16-Ch. DWDM MUX. Channels 43 - 58 (Blue) with Band splitter. MU (x16) / LC 100 GHz ITU Grid, C-Band 4.5 7 ≥25 ≥40 EM316DWDMX16-BE One Slot, passive 16-Ch. DWDM DeMUX. Channels 43 - 58 (Blue) with Band splitter. MU (x16) / LC 100 GHz ITU Grid, C-Band 4.5 7 ≥25 ≥40 EM316DWMUX32 Two slot, passive 32-Ch. DWDM MUX. Channels 21 - 52. MU (x32) / SC 100 GHz ITU Grid, C-Band 6.3 9.9 ≥25 ≥40 EM316DWDMX32 Two slot, passive 32-Ch. DWDM DeMUX. Channels 21 - 52. MU (x32) / SC 100 GHz ITU Grid, C-Band 6.3 9.9 ≥25 ≥40 EM316DWMUX32-RB Two slot, passive 32-Ch. DWDM MUX. Channels 21-36 & 43 - 58. MU (x32) / SC 100 GHz ITU Grid, C-Band 4.9 8.4 ≥25 ≥40 EM316DWDMX32-RB Two slot, passive 32-Ch. DWDM DeMUX. Channels 21-36 & 43 - 58. MU (x32) / SC 100 GHz ITU Grid, C-Band 4.9 8.4 ≥25 ≥40 2 Optical Communications Systems™ Datasheet PASSIVE DWDM OADM Description Data Port Connector Trunk Connector In/Out Max. Add/Drop Insertion Max. Other Chan. Insertion Loss (dB) Adjacent Ch. Isolation (dB) Non Adj. Ch. Isolation (dB) EM316DPADxx* One slot, 1 channel passive DWDM OADM. MU (x2) DLC/DLC Select from 100 GHz ITU Grid, C-Band channels 20-60 1.5 0.8 ≥25 ≥10 EM316DPADxxyy* One slot, 2 channel passive DWDM OADM. MU (x4) DLC/DLC Select from 100 GHz ITU Grid, C-Band channels 20-60 1.8 0.9 ≥25 ≥40 EM316DPAD4xx* One slot, 4 channel passive DWDM OADM. MU (x8) DLC/DLC Select from 100 GHz ITU Grid, C-Band channels 20-60 2.4 1.5 ≥25 ≥40 EM316DPAD8xx* One slot, 8 channel passive DWDM OADM. MU (x16) MU (x2) / MU (x2) Select from 100 GHz ITU Grid, C-Band channels 20-60 3.6 2.5 ≥25 ≥40 EM316DDADDxx* Dual Fiber, 1 channel DWDM OADM. MU (x4) MU (x2) / MU (x2) East/West (XX - Wavelength from ITU Grid Table) 1.5 1.0 ≥25 ≥40 EM316DDADDxxyy* Dual Fiber, 2 channel DWDM OADM. MU (x8) MU (x2) / MU (x2) East/West (XXYY - Wavelength from ITU Grid Table) 2.0 2.1 ≥25 ≥40 EM316DSADSxx* Single Fiber, 1 channel DWDM OADM. MU (x2) MU / MU East/West (XX - Wavelength from ITU Grid Table) 1.3 1.5 ≥25 ≥40 EM316DSADSxxyy* Single Fiber, 1 channel DWDM OADM. MU (x2) MU / MU East/West (XXYY - Wavelength from ITU Grid Table) 2.0 2.1 ≥25 ≥40 Trunk Add/Drop Wavelength (nm) Model Ordering Information *See ITU Channel Table for xx and yy substitution values. ITU CHANNEL TABLE 1544.53 1543.73 1542.94 1542.14 1541.35 1540.56 54 55 56 57 58 59 60 1529.55 Wavelength (nm) 1545.32 45 1530.33 1557.36 44 1546.12 1558.17 43 1531.12 1558.98 42 1546.92 1559.79 41 1531.90 1560.61 ITU Channel (xx or yy) 1547.72 Wavelength (nm) 1532.68 40 1548.52 39 1533.47 38 1549.32 37 46 47 48 49 50 51 52 53 1534.25 36 1550.12 35 1535.04 34 1550.92 33 1535.82 32 1551.72 31 1536.61 30 1552.52 29 1537.40 28 1553.33 27 1538.19 26 1554.13 25 1538.98 24 1554.94 23 1539.77 22 1555.75 21 1556.56 ITU Channel (xx or yy) MRV has more than 50 offices throughout the world. Addresses, phone numbers and fax numbers are listed at www.mrv.com. Please e-mail us at [email protected] or call us for assistance. MRV Los Angeles 20415 Nordhoff Street Chatsworth, CA 91311 800-338-5316 818-773-0900 MRV Boston 300 Apollo Drive Chelmsford, MA 01824 800-338-5316 978-674-6800 MRV International Business Park Moerfelden Waldeckerstrasse 13 64546 Moerfelden-Walldorf Germany Tel. (49) 6105/2070 Fax (49) 6105/207-100 All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information. MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders. MRV-FD-DWDMMUX-102510 3020034-001 Rev. A2 Copyright ©2010 MRV Communications, Inc. All Rights Reserved.