UNPACKING
Unpack the instrument carefully. Make sure all components
have been removed from the foam protection. Inspect all
components for damage. Report any concealed damage to
the carrier within 24 hours. Check the contents of the carton/crates against the packing slip and report any discrepancies to Magnetrol. Check the nameplate model number to
be sure it agrees with the packing slip and purchase order.
Check and record the serial number for future reference
when ordering parts.
0038
These units are in compliance with:
1. The EMC directive 2004/108/EC. The units have been
tested to EN 61326: 1997 + A1 + A2
2. The PED directive 97/23/EC (pressure equipment
directive). Safety accessories per category IV module
H1.
Model and
serial number
High alarm
▼
Filling line
Nozzle mounting: gap must be free
min.
25 mm
▼
MOUNTING
Low alarm
High alarm
Front view
of gap
Low alarm
Pump protection
Pump
Gap indication
2
Threaded
Welded flange
Tri-Clamp®
Wrench
flats are
aligned with
sensor gap
WIRING – RELAY VERSION: ECHOTEL 940
green
black
red
brown (NC)
+
orange (COM)
violet (NO)
OUTPUT
Level
Relay
De-energized
Energized
Wiring
NO (Violet)
COM (Orange)
NC (Brown)
NO (Violet)
COM (Orange)
NC (Brown)
IMPORTANT: When power is lost or gap is dry;
the relay de-energizes.
3
WIRING – CURRENT SHIFT VERSION: ECHOTEL 941
green
black
red
OUTPUT
Level
+
Current
8 mA (± 1 mA)
16 mA (± 1 mA)
mA
Wet gap
▼
4
Normal operation
▼
Dry gap
SPECIFICATIONS
PERFORMANCE SPECIFICATIONS
Description
Response time
Repeatability
Ambient Temperature
Humidity
Specification
0,5 s typical
± 2 mm (0.078")
-40 °C up to +85 °C (-40 °F up to +185 °F)
0-99 %, non condensing
Meets CE requirements (EN-61326: 1997 + A1 + A2) and in compliance with
Directive 2004/108/EC
Electromagnetic Compatibility
PHYSICAL/FUNCTIONAL SPECIFICATIONS
Description
Input voltage
Power consumption
Current Shift
Signal output
Relay
Potted cable
Net Weight
Specification
12 - 35 V DC
<1W
8 mA (± 1 mA) - dry gap or 16 mA (± 1 mA) - wet gap
SPDT: 1 A @ 30 V DC
45 cm (18") flying leads of 18 AWG wires
510 g (unit with 3/4" NPT transducer and shortest length)
TRANSDUCER SPECIFICATIONS
Description
Material
Mounting
Actuation length
Operating process temp.
Specification
316/316L SST (1.4401/1.4404)
Threaded (NPT/BSP) – Flanged (ANSI) – Hygienic (Tri-Clamp®)
From 3 cm up to 250 cm (1.2" up to 98.4")
-40 °C up to +85 °C (-40 °F up to +185 °F)
103 bar @ +85 °C (1500 psi @ +185 °F) - transducers > 3 cm
138 bar @ +85 °C (2000 psi @ +185 °F) - transducers = 3 cm
Flanged models are downrated to the design pressure of the selected flange
Max pressure
TEMPERATURE/PRESSURE RATING
bar
(psi)
Process pressure
200 (2900)
150 (2175)
100 (1450)
138 bar (transducer = 3 cm)
103 bar (transducer > 3 cm)
50 (725)
-40
(-40)
0
(32)
40
(100)
80
(176)
120
(250)
Process temperature
150 C
(300) (F)
5
MODEL IDENTIFICATION
A complete measuring system consists of:
1. One code for electronics and transducer
2. OPTION: Standard cable length is 45 cm (18"). Specify cable length separately when a longer cable is required.
3. OPTION: 052-7012-002: code for Echotel 941 cast aluminium housing with terminal block, 3/4" NPT cable entry, IP 65
052-7012-003: code for Echotel 940 cast aluminium housing with terminal block, 3/4" NPT cable entry, IP 65
BASIC MODEL NUMBER
9 4 0 – N
9 4 1 – N
Echotel® 940 OEM switch with integrated 1 A SPDT relay
Echotel® 941 OEM switch with current shift output 8/16 mA
PROCESS CONNECTION
Threaded
1 1 M
2 2 M
3/4" NPT
1" BSP (G 1")
2 3 M
3 3 M
4 3 M
1"
150 lbs ANSI RF
1 1/2" 150 lbs ANSI RF
2"
150 lbs ANSI RF
3 T M
4 T M
1 1/2"
2"
ANSI Flanges
Hygienic
Tri-Clamp®
Tri-Clamp®
ACTUATION LENGTH – Specify per cm (0.39") increment
Total insertion length = actuation length + 6 mm (0.25")
0 0 3
0 0 6
2 5 0
9 4
6
N
M
Minimum 3 cm (1.2") – for all connections except 1" BSP (G 1")
Minimum 6 cm (2.4") – for 1" BSP (G 1")
Maximum 250 cm (98.4")
complete code for Echotel 940/941
X = product with a specific customer requirement
DIMENSIONS IN mm (inches)
3/4" NPT
84 (3.31)
84
1)
.3
(3
3/4" NPT
105 (4.13)
65 (2.56)
89
(3.50)
3/4" NPT
cable entry
Cast aluminium housing
6 (0.25)
6 (0.25)
Ø 22,9 (0.90)
Ø 22,9 (0.90)
Model 940/941 with 1" BSP
Model 940/941 with 3/4" NPT
3/4" NPT
3/4" NPT
6 (0.25)
Actuation length
Actuation length
Ø 22,9 (0.90)
99 (3.9)
99 (3.9)
Actuation length
Actuation length
Model 940/941 with ANSI flange
6 (0.25)
Ø 22,9 (0.90)
Model 940/941 with Tri-Clamp®
7
IMPORTANT
SERVICE POLICY
Owners of Magnetrol products may request the return of a control; or, any part of a control for complete rebuilding or
replacement. They will be rebuilt or replaced promptly. Magnetrol International will repair or replace the control, at no cost to
the purchaser, (or owner) other than transportation cost if:
a. Returned within the warranty period; and,
b. The factory inspection finds the cause of the malfunction to be defective material or workmanship.
If the trouble is the result of conditions beyond our control; or, is NOT covered by the warranty, there will be charges for labour
and the parts required to rebuild or replace the equipment.
In some cases, it may be expedient to ship replacement parts; or, in extreme cases a complete new control, to replace the
original equipment before it is returned. If this is desired, notify the factory of both the model and serial numbers of the
control to be replaced. In such cases, credit for the materials returned, will be determined on the basis of the applicability of
our warranty.
No claims for misapplication, labour, direct or consequential damage will be allowed.
RETURNED MATERIAL PROCEDURE
So that we may efficiently process any materials that are returned, it is essential that a “Return Material Authorisation” (RMA)
form will be obtained from the factory. It is mandatory that this form will be attached to each material returned. This form is
available through Magnetrolʼs local representative or by contacting the factory. Please supply the following information:
1. Purchaser Name
2. Description of Material
3. Serial Number and Ref Number
4. Desired Action
5. Reason for Return
6. Process details
Any unit that was used in a process must be properly cleaned in accordance with the proper health and safety standards
applicable by the owner, before it is returned to the factory.
A material Safety Data Sheet (MSDS) must be attached at the outside of the transport crate or box.
All shipments returned to the factory must be by prepaid transportation. Magnetrol will not accept collect shipments.
All replacements will be shipped Ex Works.
BULLETIN N°:
EFFECTIVE:
SUPERSEDES:
UNDER RESERVE OF MODIFICATIONS
BE 51-647.4
MAY 2012
January 2011
www.magnetrol.com
BENELUX
FRANCE
Heikensstraat 6, 9240 Zele, België -Belgique
Tel. +32 (0)52.45.11.11 • Fax. +32 (0)52.45.09.93 • E-Mail: [email protected]
DEUTSCHLAND
Alte Ziegelei 2-4, D-51491 Overath
Tel. +49 (0)2204 / 9536-0 • Fax. +49 (0)2204 / 9536-53 • E-Mail: [email protected]
INDIA
C-20 Community Centre, Janakpuri, New Delhi - 110 058
Tel. +91 (11) 41661840 • Fax +91 (11) 41661843 • E-Mail: [email protected]
ITALIA
Via Arese 12, I-20159 Milano
Tel. +39 02 607.22.98 • Fax. +39 02 668.66.52 • E-Mail: [email protected]
U.A.E.
DAFZA Office 5EA 722 • PO Box 293671 • Dubai
Tel. +971-4-6091735 • Fax +971-4-6091736 • E-Mail: [email protected]
UNITED
KINGDOM
Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL
Tel. +44 (0)1444 871313 • Fax +44 (0)1444 871317 • E-Mail: [email protected]