OES POINT LEVEL SWITCH DESCRIPTION

7+(1(;7*(1(5$7,212)0$*1(7,&/(9(/,1',&$7,21
OES POINT LEVEL SWITCH
DESCRIPTION
The Model OES snap switch is utilized to expand the control capabilities of
Orion’s extensive line of magnetic level indicators. This cam-operated DPDT
mechanism is clamp-mounted to the outside of the MLI. This mounting style
allows easy addition or repositioning of switches without disruption of the
process.
Model: OES
Designed for optimal repeatability and reliability, the OES-100 is actuated
by simple magnetic coupling. As the liquid level moves, the MLI float (with
its internal magnets and flux rings) follows. When the float moves into the
proximity of the snap switch, the switch magnet interacts with the float’s
magnetic field actuating the switch. The bi-stable design of the switch ensures
that it will not reset until the float passes the switch in the opposite direction.
For use in Installation Category II, Pollution Degree 2. If equipment is used
in a manner not specified by the manufacturer, protection provided by the
equipment may be impaired.
OES as a high level switch
SPECIFICATIONS
Model
OES-xxxx-xxx
Type
Bi-stable, cam operated switch
Supply Voltage
250V AC/DC max
Contacts
Two SPDT (one DPDT)
Contact Rating
OES as a low level switch
10.1 amps max
Deadband
±0.75” (20 mm) float travel
Temperature Range
-58° to 392° F (-50° to 200° C)
Enclosure Rating
NEMA 4X/7/9
Enclosure Material
Mounting
Conduit/Cable Entry
AGENCY
MODEL
CATEGORY
FM
All models
Class I, Div. 1, Groups B, C, & D
Class I, Div. 2, Groups B, C, & D
CSA
All models
CE
OES-xxxx-xxx
Aluminum or stainless steel
Clamp mount to MLI or switch mount rod
(both are field adjustable)
3/4” FNPT (consult factory for alternative options)
Class I, Div. 2, Groups A, B, C, & D (FM only)
Class II, Groups E, F, & G
Class III, Type 4X
Installation Category II, Pollution Degree 2
Low Voltage Directives, 73/23/EEC & 93/68/EEC
per Harmonized Standard EN 61010-1/1993 & Amendment No. 1
MOUNTING TO ATLAS™ OR GEMINI™ MLI
‹…Š‡•
ȋȌ
3
(76)
The OES level switch is completely
field adjustable. Simply loosen the
included mounting clamps and
position at the desired location.
Ensure that the switch always
remains in close proximity to the
internal float.
5.5
(139)
Position the OES cam-operated snap switch on the MLI body so that
the centerline of the switch enclosure is at the desired switch point
level. Ensure that the switch is oriented so that the arrow on the
internal mechanism is pointing toward the top of the MLI. Install
the clamps around the MLI and over the mounting brackets on the
top and bottom of the OES housing. Tighten the clamps until the
switch is firmly secured to the MLI. Replace the housing cover. If
required, place the insulation between the MLI body and the OES
before securing the clamps.
8.38
(212)
I N S T R U MENTS
MADE IN USA
I N S T R U M ENTS
BATON ROUGE, LA
PHONE 1-225-906-2343
FAX 1-225-906-2344
WWW.ORIONINSTRUMENTS.COM
MODEL NO.:
SERIAL NO.:
MAX. PRESSURE:
MAX. TEMPERATURE:
TAG NO.:
MOUNTING TO AURORA® MLI
Special care must be taken when adding OES switches to an
Aurora® after initial purchase. For proper function, the switch
must be located as close to the internal
float magnet as possible. To achieve this,
slight repositioning of the visual indicator
may be required.
Physical Dimensions
A switch mount rod is an available
alternative method for mounting
the OES to an MLI when insulation is
present. The rod assembly, which is
welded to the MLI chamber, allows the
switch to slide along the full length.
When the desired position is selected,
simply tighten it in place.
WIRING
The lower conduit opening is protected
with a plastic shipping plug. The upper
opening is sealed with a steel plug. If it
is preferable to wire through the upper
conduit entry, the steel plug may be
moved to the lower opening. The DPDT
switch has two sets of contacts. Refer to
diagram above or label on mechanism.
F LOAT
ORION INSTRUMENTS
OES ELECTRIC SWITCH
INSTALL WITH ARROW POINTING UP
FLOAT BELOW SWITCH
CAUTION:
If equipment is used in a manner not specified by the manufacturer,
protection provided by the equipment may be impaired.
OES 10-Amp DPDT Point Level Switch
O
1
E
S
2
3
4
5
6
0
0
1
8
9
10
7
4
ENCLOSURE
6
CHAMBER MOUNTING CODE
A
Cast aluminum
1
MLI model code digit 20 is 1, 2, or 7
S
Stainless steel
2
MLI model code digit 20 is 3, 4, 5 or 6
3
MLI model code digit 20 is A, B, C, or D
AGENCY APPROVAL
4
MLI model code digit 20 is E, F, G, H, or J
FM/CSA
5
MLI is a Top Mount design
5
1
7
MOUNTING STYLE
C
Clamp mounted on MLI (standard)
P
Clamp mounted on MLI with insulation pad
R
Attached to switch mount rod
6646 Complex Drive • Baton Rouge, Louisiana 70809 • 225-906-2343 • Toll Free 866-55-ORION (866-556-7466) • Fax 225-906-2344 • www.orioninstruments.com
Effective January 1, 2011: 2105 Oak Villa Drive • Baton Rouge, Louisiana 70815
Copyright © 2010 Orion Instruments, LLC. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
Orion, Orion logotype, Magnetrol, Magnetrol logotype, and Aurora are registered trademarks of Magnetrol International.
Atlas and Gemini are trademarks of Magnetrol International.
BULLETIN: OES-100.2