MA-COM 6VJ1

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Power Entry Module with Voltage Selection and Fusing
J Series
UL Recognized
CSA Certified
Front View, all models
6J4
6HJ4
J Series
Specifications
• Power entry module with North American style
3AG fuse holder
• 2 or 4 voltage selection
• Compact snap-in design
• Two element circuit provides basic
EMI attenuation
• Available with minimal leakage current suitable
for medical applications (HJ models)
• Also available without filter (VJ models)
Maximum leakage current each Line to Ground:
6HJ4 or
6J4 Models
non–filtered
@250 VAC 50 Hz:
500 A
5 A
Hipot rating (one minute):
Line to Ground:
Line to Line:
Operating Voltage:
suffix - 1 or - 4 models:
suffix - 2 models:
1550 VAC
1450 VDC
100, 120, 220 or 240VAC
115 or 230 VAC
Operating Frequency:
Ordering Information
50/60 Hz
Rated Current:
6A
Required Fuse:
.25 x 1.25
(not included)
6 H J 4 -4
Available Voltage Selections
1 - Four (non–filtered versions)
2 – Two
4 or blank – Four (filtered versions)
Filtered Indicator
1 – Non–filtered
4 – Filtered
Available Part Numbers
J Series
Filter Type
H – Medical
V – Non-filtered
Blank – general purpose
Non–filtered models
6VJ1
6VJ1-2
General Purpose Filters
6J4
6J4-2
Medical Filters
Current Rating
6A
6HJ4-4
6HJ4-2
172
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
Power Entry Module with Voltage Selection and Fusing
(continued)
J Series
Electrical Schematics
6VJ1 & 6VJ1-2
Accessories
GA400:NEMA 5-15P to IEC 60320-1 C-13 line cord
Note 3
Power On/Off
Off
R
S
H
On
Pilot
light
Ground
A
A
B
B
20V
100V
J
C
D
D
K
E
L
F
Transformer
primary
120V
M
Note 2
Neutral
P
220V
240V
120V
100V
Note 2
Hot
Note 1
N
JA302: 2 Voltage Select Card
Comes standard with 6VJ1-2, 6J4-2 and
6HJ4-2
6J4 & 6J4-2
Note 3
220V
240V
120V
100V
A
Hot
Ground
Neutral
B
C
C
D
D
E
E
F
F
Transformer
primary
JA403: Mounting clips for .105 - .125” panels
120V
JA410-419: Equipment Rating Labels
Self-adhesive, available in multiples of 40
Specify part number
6HJ4-4 & 6J4-2
2.330
Note 3
220V
240V
120V
100V
A
Neutral
J
H
Note 1



Fuse
A
B
B
C
C
A
100V
Pilot
light
On
.210
Line V. + 5 - 10%
48-440 - 50 VA Max.
100/120V (115V)
220/240V (230V)
500mA
250mA
B
C
20V
Power On-Off
Off
Ground
Power Inlet Filters & Power Entry Modules
J
H
Note 1
Hot
3
Comes standard with 6VJ1, 6J4 and 6HJ4-4
B
100V
Pilot
light
On
JA304: 4 Voltage Select Card
A
20V
Power On-Off
Off
D
D
E
E
F
F
Transformer
primary
A
120V



Voltage Selection
Part No.
JA410
JA411
JA412
JA413
JA414
JA415
JA416
JA417
JA418
JA419
B
VA
max.
25
50
100
200
250
300
400
500
600
Assortment
C
Fuse
Fuse
100/120 (115) 220/240 (230)
250 mA
500 mA
1A
2A
2.5A
3A
4A
5A
6A
125 mA
250 mA
500 mA
1A
1.25A
1.5A
2A
2.5A
3A
JA410-JA418: 40 labels of one part number
JA419:
5 each of JA410 - JA418 (45 labels)
Open cover door and slide fuse-pull lever to left.
Select operating voltage by orienting voltage selection card with the desired voltage on top left side.
Push card firmly into module slot. Slide fuse-pull lever
to right into normal position and re-insert fuse into
holders.
JA500: Voltage Selector Card Extractor Tool
Use caution in selecting correct fuse value.
173
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
Power Entry Module with Voltage Selection and Fusing
(continued)
J Series
Case Styles
Case Dimensions
Part No.
Non-filtered Models
6VJ1, 6VJ1-2
C
B
C
D



















D
B
A



6J4, 6J4-2,
6HJ4-4, 6HJ4-2
A

Performance Data


Typical Insertion Loss
Measured in closed 50 Ohm system
Filtered Models
6J4
6HJ4
db
100
db
100
90
90
80
C
D
B
A



80
70
70
60
60
50
50
40
40
30
30
20
20
10
0
10
0.1
1
10
30
Frequency in MHz
0
0.1
1
10
30
Frequency in MHz


Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Recommended Panel Cutouts
Door Open Position
Minimum Insertion Loss
1.063* 1.17
27.0
29.7
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Bezel
Clearance
2.60*
66.0
  
*± .003 [.076]
2.68
68.1
3.00
76.2
 


























174
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com