F10-F50 Flow Switches Sales Literature BE47-116

F10 - F50
®
Flow Switches
DESCRIPTION
Standard & tailor made designs
Magnetrol flow switches are highly reliable devices utilized
to sense the start or stop of flow in horizontal pipelines containing oil and petroleum derivatives, chemicals, water, or
air.
Vane actuated model F10 switches are used on gas or liquid flow applications in 2" or larger pipe sizes.
Disc actuated model F50 switches are in-line type used for
sensing clean liquids in 2" or smaller pipe sizes.
F E AT U R E S
• Actuation on increasing or decreasing flow
• Special sensing elements for non-standard or high flow
applications
• Designed for horizontal pipe applications
• Standard anti corrosive protection
Model F10:
- Field adjustable
- Low pressure drop
- Process temperature up to +230 °C (+450 °F)
- Process pressure up to 69 bar (1000 psi)
- Standard flow vanes for 2" thru 10" flow lines
Model F50:
- No calibration required
- Bronze or stainless steel construction
- Process temperature up to +400 °C (+750 °F)
- Process pressure up to 79,3 bar (1150 psi)
- Bodies for flow lines from 3/4" to 2"
F10
F50
A G E N C Y A P P R O VA L S
Agency
Approval
ATEX
II 2G EEx d II C T6, explosion proof
II 1G EEx ia II C T6, intrinsically safe
CENELEC
CCE ➀
EEx d II C T6, explosion proof
A P P L I C AT I O N S
FM
•
•
•
•
•
•
•
•
FM/CSA ➁
Class I, Div. 1, Groups C & D
Class II, Div. 1, Groups E, F & G, Type NEMA 7/9
Non-Hazardous area
Pump staging or failure
Pipeline flow detection
Valve failure
Loss of pipeline flow
Pipe blockage/rupture
Pump inlet flow protection
Check valve blockage/leakage
Alarm on eyewash or shower safety station
R1 (1) 136/MI/433, explosion proof
Explosion proof area –
Groups B, C, D, E, F & G Type NEMA 4X/7/9
SAA ➁
LRS
Explosion proof area
Lloyds Register of Shipment (marine applications)
GOST/
GOSGORTECHNADZOR ➁
Russian Authorisation Standards
Other approvals are available, consult factory for more details
➀ For CCE approved units, use the ATEX explosion proof model
numbers.
➁ Consult factory for proper model numbers.
Worldwide level and flow solutions
P R I N C I P L E O F O P E R AT I O N
F10
The actuating vane is magnetically linked to a pivoted electric (or pneumatic) switch, which is isolated from the
process by a non-magnetic barrier tube. As the actuating
vane moves with an increase in flow, it drives a magnetic
sleeve into the field of a permanent magnet located outside the barrier tube which trips the switch. As flow
decreases, the actuating vane returns to a vertical position, allowing the magnet and switch assembly to return to
the “No Flow” position.
Switch mechanism
Adjusting
screw
Barrier tube
(non magnetic)
Magnetic
sleeve
Magnet
Actuating
vane
No flow position
Mechanism
switch
Pivot
4
5
Tension
spring
6
Barrier tube
(non magnetic)
4
5
6
Sleeve
(magnetic)
Swing out
position
Magnet
Swing in
position
Flow disc
No flow position
Position with
actuating flow present
Position with
actuating flow present
F50
The rate of flow through the valve body raises or lowers the
disc. This in turn raises or lowers the magnetic sleeve, within its sealed non-magnetic barrier tube. On an increasing
flow rate, the magnetic sleeve rises into the field of the
permanent magnet, located outside the barrier tube, actuating the attached switch mechanism. When the flow rate
drops, below the rate for which the flow disc is calibrated, a
reversal of this action occurs.
MOUNTING
FLOW
Input line
Additive flow
Overflow detection
FLOW
Leak detection
Overflow
tank
Pump
protection
FLOW
Primary
tank
E L E C T R I C A L S P E C I F I C AT I O N S
2
Description
Specification
Switch ratings
Up to 15 A @ 240 V AC (depending on switch mechanism)
Up to 10 A @ 120 V DC (depending on switch mechanism)
Signal Output
Single SPDT or DPDT contacts or single pneumatic
Switch Types (see table on page 3)
Dry contact with standard or gold alloy contacts, Mercury, Hermetically sealed,
Hermetically sealed with gold or silver plated contacts, Proximity switch,
or single pneumatic bleed and non bleed
Approvals (see table on page 1)
ATEX II 2G EEx d II C T6, explosion proof
ATEX II 1G EEx ia II C T6, intrinsically safe
CENELEC EEx d II C T6, explosion proof
FM/CSA/SAA, explosion proof
LRS, Lloyds Register of Shipment (marine applications)
GOST/GOSGORTECHNADZOR, Russian Authorisation standards
Other approvals are available, consult factory.
Cable entries
M20 x 1,5 ISO, 1" NPT and 3/4" NPT (or others at request)
AVA I L A B L E S W I T C H M E C H A N I S M S
Max. Process Temp. ➁
Switch ratings – A res. ➂
➄
F50
F10
24 V DC 240 V AC 120 V AC
Micro switch
max +120 °C (+250 °F)
6
15
15
Micro switch
max +230 °C (+450 °F)
10
15
15
Micro switch - DC current
max +120 °C (+250 °F)
10
–
10
Micro switch with gold alloy contacts
max +120 °C (+250 °F)
1
–
1
Hermetically sealed micro switch
max +230 °C (+450 °F)
not applicable
5
5
5
Hermetically sealed micro switch with
max +230 °C (+450 °F)
3
1
1
silver plated contacts
Hermetically sealed micro switch with
max +230 °C (+450 °F)
0,5
0,5
0,5
gold plated contacts
Hermetically sealed micro switch
not applicable
max +400 °C (+750 °F)
4
–
2,5
Proximity switch - type SJ 3.5 SN
max +100 °C (+210 °F)
NA
NA
NA
Mercury switch
max +230 °C (+450 °F) max +290 °C (+500 °F)
10
6,5
13
Mercury switch
not applicable
max +400 °C (+750 °F)
10
6,5
13
Pneumatic bleed type (open air)
max +200 °C (+400 °F)
NA
NA
NA
Pneumatic non bleed type
max +200 °C (+400 °F)
NA
NA
NA
(closed circuit)
Type of switch module ➀
➀
➁
➂
➃
➄
Code
B
C
D
U
HS ➃
W
X
F
V
A
3
J
K
For applications with heavy vibration, consult factory for suited switch modules.
Max process temperature is specified at +40 °C (+100 °F) ambient temperature and for non condensing applications.
For more details - see bulletin BE 42-120.
For condensing applications, max process temperature is down-rated to +200 °C (+400 °F) @ +40 °C (+100 °F) ambient.
For bronze construction, max process temperature is downrated to +260 °C (+500 °F).
Type B, C, D & U
Type HS
Type F, W & X
Type V
Type A & 3
Type J & K
AVA I L A B L E H O U S I N G S
•
•
•
•
•
For Non Ex use
IP 66
Die cast Aluminium
2 Entries (one plugged)
Standard blue
anti corrosive coating
• Housing heater/drain
available, consult factory
•
•
•
•
•
For Exd/Exi use
IP 66
Die cast Aluminium
2 Entries (one plugged)
Standard blue
anti corrosive coating
• ATEX II 2G EEx d II C T6
• ATEX II 1G EEx ia II C T6
•
•
•
•
For Exd use
IP 66
Cast Iron
One entry (2 entries at
request)
• Standard blue
anti corrosive coating
• CENELEC EEx d II C T6
•
•
•
•
For pneumatic switches
IP 53 (NEMA 3R)
IP 55 optional at request
Alu base / cold rolled steel
cover
• Standard blue
anti corrosive coating
•
•
•
•
•
For Exd use
IP 66 (NEMA 7/9)
Die cast Aluminium
2 Entries (one plugged)
Standard blue
anti corrosive coating
• FM, Class I, Div. 1,
Groups C & D
• FM, Class II, Div. 1,
Groups E, F & G
3
S E L E C T I O N D ATA – F 1 0
Actuating flow rates (water service) – m3/h
Model F10 units may be adjusted in service to actuate
within the minimum and maximum flow rates given below
(based on schedule 40 pipe). A specific gravity correction
factor is applied for liquids other than water (1.00 specific
gravity).
Pipe
size
Flow
increase
Pipe
size
decrease
Max. inches
Flow
increase
decrease
Specific gravity correction for actuating flow rates – m3/h
To determine the actuating flow rates for liquids other than
water (approximate viscosity of 20 cP or less) a specific
gravity correction factor must be applied to the water flow
rates given in the table.
Specific
Gravity
Multiplication
Factor
Specific
Gravity
Multiplication
Factor
inches
Min.
Max.
Min.
Min.
Max.
Min.
Max.
0.40
1.58
0.95
1.03
2.00
4.8
14.3
3.6
10.9
14.00
61.3
97.6
38.6
63.6
0.45
1.49
1.00
1.00
2.50
5.2
16.8
4.5
12.7
16.00
77.2 115.8
49.9
72.6
0.50
1.41
1.05
0.98
3.00
7.3
20.0
5.4
14.8
18.00
97.6 133.9
61.3
84.0
0.55
1.35
1.10
0.95
3.50
8.6
22.7
6.4
17.0
20.00 118.0 156.6
72.6
97.6
0.60
1.29
1.15
0.93
4.00
10.2
27.2
7.5
19.3
22.00 140.7 177.1
86.3 109.0
0.65
1.24
1.20
0.91
5.00
13.8
34.1
9.8
25.0
24.00 165.7 204.3 102.2 124.9
0.70
1.20
1.25
0.89
6.00
17.9
40.9
12.5
29.5
26.00 193.0 233.8 118.0 140.7
0.75
1.15
1.30
0.88
8.00
27.2
52.2
18.6
36.3
28.00 222.5 263.3 133.9 158.9
0.80
1.12
1.35
0.86
10.00
38.6
70.4
25.0
47.7
30.00 252.0 292.8 152.1 177.1
0.85
1.08
1.40
0.85
12.00
52.2
86.3
34.1
56.8
0.90
1.05
1.45
0.83
For higher/lower flow rates, consult factory.
P H Y S I C A L S P E C I F I C AT I O N S – F 1 0
Description
Specification
Measured variable
Physical range
Flow rate
Increasing flow
From 4,8 m3/h (2" pipe size) up to 292,8 m3/h (30" pipe size)
Decreasing flow
From 3,6 m3/h (2" pipe size) up to 177,1 m3/h (30" pipe size)
Process temperature
Process pressure
(for higher ratings consult factory)
Up to 69 bar @ +230 °C (1000 psi @ +450 °F)
Process connection material
Carbon steel or stainless steel
Wetted materials
Vane and trim
302 SST (1.4300) and 316 SST (1.4401)
Magnetic sleeve
316 SST (1.4401)
EXPEDITE SHIP PLAN (ESP)
Several mechanical switches are available for quick shipment, within max. 3 weeks after factory receipt of purchase order,
through the Expedite Ship Plan (ESP).
Models covered by ESP service are conveniently grey coded in the selection data charts.
To take advantage of ESP, simply match the grey coded model number codes (standard dimensions apply).
ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume
orders, as well as other products and options.
S E L E C T I O N D ATA – F 1 0
Select pneumatic switch mechanism & enclosure
Pneumatic switch type
Series J
(open air)
Series K
(closed circuit)
4
Max supply pressure
bar (psi)
Max liquid temperature
°C (°F)
Bleed orifice Ø
mm (inches)
NEMA 3R (IP 53)
6,9 (100)
+200 (+400)
1,60 (0.063)
JGF
4,1 (60)
+200 (+400)
2,39 (0.094)
JHF
6,9 (100)
+200 (+400)
–
KOF
S E L E C T I O N D ATA – F 1 0
A complete measuring system consists of:
1. Order code for F10 models
2. Order code for modified models or adders: put an "X" in front of the closest matching order code and specify the modifications/adders separately
eg. XF10-AD22-BK9
X = with material certification EN 10204 / DIN 50049-3.1.B
1. Order code for F10 flow switch
BASIC MODEL NUMBER
F 1 0
vane actuated flow switch – field adjustable setpoint
MATERIALS OF CONSTRUCTION
D
316 SST (1.4401)
Code
A
Process
connection material
Carbon steel
Vane and trim
Magnetic sleeve
302 SST (1.4300) &
316 SST (1.4401)
316 SST (1.4401)
PIPE SIZE AND PROCESS CONNECTION
Pipe size
Process connection
Pipe size
Process connection
D 2 2
2"
2" NPT
E 6 4
4"
2 1/2" - 300 lbs RF
D 2 4
4"
2" NPT
E 6 6
6"
2 1/2" - 300 lbs RF
D 2 6
6"
2" NPT
E 6 8
8"
2 1/2" - 300 lbs RF
D 2 8
8"
2" NPT
E 6 0
10"
2 1/2" - 300 lbs RF
D 2 0
10"
2" NPT
E 5 4
4"
2
- 150 lbs RF
E 7 4
4"
2 1/2" - 600 lbs RF
E 5 6
6"
2 1/2" - 150 lbs RF
E 7 6
6"
2 1/2" - 600 lbs RF
- 150 lbs RF
E 7 8
8"
2 1/2" - 600 lbs RF
2 1/2" - 150 lbs RF
E 7 0
10"
2 1/2" - 600 lbs RF
E 5 8
8"
E 5 0
10"
2
1/2"
1/2"
SWITCH MECHANISM & ENCLOSURE
- for electric switch mechanisms (see below)
- for pneumatic switch mechanisms (see left page)
complete order code for F10 models
F 1 0
Select electric switch mechanism & enclosure
qty and
switch
type
A
B
C
D
HS
U
V
W
X
Weather proof
(IP 66)
CENELEC (IP 66)
FM (IP 66)
II 2G EEx d II C T6
II 1G EEx ia II C T6
EEx d II C T6
NEMA 7/9
cast Aluminium
cast Aluminium
cast Aluminium
cast Iron
cast Alu.
ATEX (IP 66)
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
3/4" NPT
1 x SPDT
A2B
AAB
AK9
AC9
–
–
AK5
AU5
1" NPT
AKB
1 x DPDT
A8B
ADB
AN9
AF9
–
–
AD5
AW5
ANB
1 x SPDT
B2B
BAB
BK9
BC9
–
–
BK5
BU5
BKB
1 x DPDT
B8B
BDB
BN9
BF9
–
–
BD5
BW5
BNB
1 x SPDT
C2B
CAB
CK9
CC9
C2T
CAT
CK5
CU5
CKB
1 x DPDT
C8B
CDB
CN9
CF9
C8T
CDT
CD5
CW5
CNB
1 x SPDT
D2B
DAB
DK9
DC9
–
–
DK5
DU5
DKB
1 x DPDT
D8B
DDB
DN9
DF9
–
–
DD5
DW5
DNB
1 x SPDT
H7A
HM2
HFC
HA9
–
–
HB3
HB4
HM3
1 x DPDT
H7C
HM6
HGC
HB9
–
–
HB7
HB8
HM7
1 x SPDT
U2B
UAB
UK9
UC9
U2T
UAT
UK5
UU5
UKB
1 x DPDT
U8B
UDB
UN9
UF9
U8T
UDT
UD5
UW5
UNB
–
–
–
–
–
VCS
VES
–
–
–
1 x SPDT
W2B
WAB
WK9
WC9
W2T
WAT
WK5
WU5
WKB
1 x DPDT
W8B
WDB
WN9
WF9
W8T
WDT
WD5
WW5
WNB
1 x SPDT
X2B
XAB
XK9
XC9
X2T
XAT
XK5
XU5
XKB
1 x DPDT
X8B
XDB
XN9
XF9
X8T
XDT
XD5
XW5
XNB
5
S E L E C T I O N D ATA – F 5 0
Specific gravity correction for actuating flow rates – m3/h
To determine the actuating flow rates for liquids other than
water (approximate viscosity of 20 cP or less), a
specific gravity correction factor must be applied to the
water flow rates given in the table. For gas/air applications,
consult factory.
Specific
Gravity
Multiplication
Factor
Specific
Gravity
Multiplication
Factor
0.40
1.58
0.95
1.03
0.45
1.49
1.00
1.00
0.50
1.41
1.05
0.98
0.55
1.35
1.10
0.95
0.60
1.29
1.15
0.93
0.65
1.24
1.20
0.91
0.70
1.20
1.25
0.89
0.75
1.15
1.30
0.88
0.80
1.12
1.35
0.86
0.85
1.08
1.40
0.85
0.90
1.05
1.45
0.83
1400
1400
1200
1200
pressure drop in mbar
pressure drop in mbar
P R E S S U R E D R O P TA B L E S – F 5 0
1000
800
600
400
200
1000
800
600
400
200
0
0
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
5
5,5
6
6,5
7
7,5
0
0,5
1
1,5
2
2,5
3
3,5
3/4"
NPT connection
4,5
5
5,5
6
6,5
32
34
7
7,5
8
1" NPT connection
1400
pressure drop in mbar
1400
pressure drop in mbar
4
flow in m3/h
flow in m3/h
1200
1000
800
600
400
200
1200
1000
800
600
400
200
0
0
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
0
2
4
6
8
10
12
flow in m3/h
14
16
18
20
22
24
26
28
30
36
38
40
42
flow in m3/h
11/2" NPT connection
2" NPT connection
P H Y S I C A L S P E C I F I C AT I O N S – F 5 0
Description
Specification
Measured variable
Flow rate
Physical range
Process temperature
Process pressure
(for higher ratings
consult factory)
Increasing flow
From 0,25 m3/h (3/4" pipe size) up to 5,63 m3/h (2" pipe size)
Decreasing flow
From 0,18 m3/h (3/4" pipe size) up to 4,77 m3/h (2" pipe size)
Bronze models
Up to 27,6 bar @ +40 °C (400 psi @ +100 °F)
Up to +260 °C @ 13,8 bar (+500 °F @ 200 psi)
Stainless steel
models
Up to 79,3 bar @ +40 °C (1150 psi @ +100 °F)
Up to +400 °C @ 41,3 bar (+750 °F @ 600 psi)
Body material
Wetted materials
Bronze or stainless steel
Disc and trim
316 SST (1.4401)
Magnetic sleeve
316 SST (1.4401) or 400 series SST
S E L E C T I O N D ATA – F 5 0
Select pneumatic switch mechanism & enclosure
Max supply pressure
bar (psi)
Max liquid temperature
°C (°F)
Bleed orifice Ø
mm (inches)
Series J
(open air)
6,9 (100)
+200 (+400)
1,60 (0.063)
JDG
JDE
4,1 (60)
+200 (+400)
2,39 (0.094)
Series K
(closed circuit)
6,9 (100)
+200 (+400)
–
JEG
KOE➁
KOE
2,8 (40)
+200 (+400)
–
KOG
–
➀ Use switch codes with material code D for F50-AC2E / F50-AC2F / F50-AD2E / F50-AD2F
➁ Only in combination with F50-AC2E / F50-AC2F / F50-AD2E / F50-AD2F
6
NEMA 3R (IP 53)
material code D
material code A ➀
Pneumatic
switch type
JEE
S E L E C T I O N D ATA – F 5 0
A complete measuring system consists of:
1. Order code for F50 models.
2. Order code for modified models or adders: put an "X" in front of the closest matching order code and specify the modifications/adders separately
eg. XF50-AB2C-A2P
X = process connection 1" - 150 lbs RF ANSI flanges
1. Order code for F50 flow switch
BASIC MODEL NUMBER
F 5 0
mechanical disc actuated flow switch
Code
MATERIALS OF CONSTRUCTION
Body material
A
Bronze & carbon steel nut
300 series SST
400 series SST
D
316 SST (1.4401)
316 SST (1.4401)
316 SST (1.4401)
Flow disc and trim
Magnetic sleeve
PROCESS CONNECTION AND ACTUATING FLOW RATES
Actuating flow rate
Process
connection
Actuating flow rate
Process
connection
increasing
decreasing
increasing
decreasing
NPT
0,25 m3/h
0,18 m3/h
C 2 A
11/2"
NPT
0,30 m /h
0,25 m3/h
A 2 C
3/4"
NPT
0,36 m /h
0,27 m /h
C 2 B
11/2" NPT
0,61 m /h
0,52 m3/h
A 2 D
3/4"
NPT
0,52 m3/h
0,41 m3/h
C 2 C
11/2" NPT
1,07 m3/h
0,91 m3/h
A 2 E
3/4"
NPT
0,77 m /h
0,59 m /h
C 2 D
11/2" NPT
1,73 m /h
1,48 m3/h
A 2 F
3/4"
NPT
1,11 m3/h
0,84 m3/h
C 2 E
11/2" NPT
2,79 m3/h
2,38 m3/h
B 2 A
1" NPT
0,23 m /h
0,18 m /h
C 2 F
11/2" NPT
4,79 m3/h
4,06 m3/h
B 2 B
1" NPT
0,39 m /h
0,32 m /h
D 2 A
2" NPT
0,43 m /h
0,36 m3/h
B 2 C
1" NPT
0,57 m /h
0,48 m /h
D 2 B
2" NPT
0,70 m3/h
0,61 m3/h
B 2 D
1" NPT
0,84 m /h
0,68 m /h
D 2 C
2" NPT
1,16 m /h
0,98 m3/h
B 2 E
1" NPT
1,25 m3/h
1,02 m3/h
D 2 D
2" NPT
1,91 m3/h
1,61 m3/h
B 2 F
1" NPT
1,61 m /h
1,32 m /h
D 2 E
2" NPT
3,25 m /h
2,75 m3/h
D 2 F
2" NPT
5,63 m3/h
4,77 m3/h
A 2 B
3/4"
3
3
3
3
3
3
3
3
3
3
3
3
3
3
SWITCH MECHANISM & ENCLOSURE
F 5 0
3
3
3
3
3
3
- for electric switch mechanisms (see below)
- for pneumatic switch mechanisms (see left page)
complete order code for F50 models
2
Select electric switch mechanism & enclosure
All models with material code A ➀
qty and
switch
type
A
3
B
C
D
F
U
V
W
X
Weather proof
(IP 66)
cast Aluminium
All models with material code D
ATEX (IP 66)
CENELEC (IP 66)
FM (IP 66)
II 2G EEx d IIC T6 II 1G EEx ia II C T6
EEx d IIC T6
NEMA 7/9
Weather proof
(IP 66)
cast Iron
cast Alu.
cast Aluminium
M20 x 1,5 3/4" NPT
cast Aluminium
cast Aluminium
ATEX (IP 66)
CENELEC (IP 66)
II 2G EEx d IIC T6 II 1G EEx ia II C T6
EEx d IIC T6
NEMA 7/9
cast Iron
cast Alu.
M20 x 1,5 3/4" NPT
1" NPT
cast Aluminium
cast Aluminium
FM (IP 66)
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
1 x SPDT
A2P
AAP
AHC
AAC
-
-
AK7
AU7
AKP
A2Q
AAQ
AH9
AA9
-
-
AK5
AU5
AKQ
1 x DPDT
A8P
ADP
AJC
ABC
-
-
AD7
AW7
ANP
A8Q
ADQ
AJ9
AB9
-
-
AD5
AW5
ANQ
1 x SPDT
32P
3AP
3HC
3AC
-
-
3K7
3U7
3KP
32Q
3AQ
3H9
3A9
-
-
3K5
3U5
3KQ
1 x DPDT
38P
3DP
3JC
3BC
-
-
3D7
3W7
3NP
38Q
3DQ
3J9
3B9
-
-
3D5
3W5
3NQ
1 x SPDT
B2P
BAP
BHC
BAC
-
-
BK7
BU7
BKP
B2Q
BAQ
BH9
BA9
-
-
BK5
BU5
BKQ
1 x DPDT
B8P
BDP
BJC
BBC
-
-
BD7
BW7
BNP
B8Q
BDQ
BJ9
BB9
-
-
BD5
BW5
BNQ
1 x SPDT
C2P
CAP
CHC
CAC
C2L
CAL
CK7
CU7
CKP
C2Q
CAQ
CH9
CA9
C2S
CAS
CK5
CU5
CKQ
1 x DPDT
C8P
CDP
CJC
CBC
C8L
CDL
CD7
CW7
CNP
C8Q
CDQ
CJ9
CB9
C8S
CDS
CD5
CW5
CNQ
1 x SPDT
-
-
-
-
-
-
-
-
-
D2Q
DAQ
DH9
DA9
-
-
DK5
DU5
DKQ
1 x DPDT
-
-
-
-
-
-
-
-
-
D8Q
DDQ
DJ9
DB9
-
-
DD5
DW5
DNQ
1 x SPDT
F2P
FAP
FHC
FAC
-
-
FK7
FU7
FKP
F2Q
FAQ
FH9
FA9
-
-
FK5
FU5
FKQ
1 x DPDT
F8P
FDP
FJC
FBC
-
-
FD7
FW7
FNP
F8Q
FDQ
FJ9
FB9
-
-
FD5
FW5
FNQ
1 x SPDT
U2P
UAP
UHC
UAC
U2L
UAL
UK7
UU7
UKP
U2Q
UAQ
UH9
UA9
U2S
UAS
UK5
UU5
UKQ
1 x DPDT
U8P
UDP
UJC
UBC
U8L
UDL
UD7
UW7
UNP
U8Q
UDQ
UJ9
UB9
U8S
UDS
UD5
UW5
UNQ
-
-
-
-
-
VFS
VHS
-
-
-
-
-
-
-
V5S
VBS
-
-
-
1 x SPDT
W2P
WAP
WHC
WAC
W2L
WAL
WK7
WU7
WKP
W2Q
WAQ
WH9
WA9
W2S
WAS
WK5
WU5
WKQ
WNQ
1 x DPDT
-
-
-
-
-
-
-
-
-
W8Q
WDQ
WJ9
WB9
W8S
WDS
WD5
WW5
1 x SPDT
X2P
XAP
XHC
XAC
X2L
XAL
XK7
XU7
XKP
X2Q
XAQ
XH9
XA9
X2S
XAS
XK5
XU5
XKQ
1 x DPDT
-
-
-
-
-
-
-
-
-
X8Q
XDQ
XJ9
XB9
X8S
XDS
XD5
XW5
XNQ
➀ Use switch codes with material code D for F50-AC2E / F50-AC2F / F50-AD2E / F50-AD2F
7
DIMENSIONS in mm (inches)
X
Pipe size
Dim. A max.
2"
Equivalent max.
wall schedule
X
Y
Y
Dim. B
46 (1.81)
180
40 (1.59)
2 1/2" 49 (1.94)
160
53 (2.09)
3"
48 (1.88)
180
68 (2.66)
3 1/2" 48 (1.88)
180
79 (3.12)
4"
51 (2.00)
120
94 (3.69)
5"
52 (2.06)
120
118 (4.66)
6"
54 (2.12)
120
145 (5.72)
8"
56 (2.19)
100
195 (7.69)
10"
59 (2.31)
100
254 (10.00)
V
2" NPT
W
2" NPT 3000# bonney
threadolet or equal
(supplied by customer)
FLOW
over 10" 59 (2.31)
V
Z
Z
63
(2.50)
A
W
133
(5.25) 187
(7.38)
Dim
"B"
44
(1.75)
Pipe size
(horizontal lines only)
3" pipe and up
Vane width 38
(1.50)
65 ø ± 1,5
(2.56 ø ± 0.06)
76 ø (3.00)
5 (0.19)
minimum
Flow vane
2" and 2 1/2" pipe
Y
Y
X
X
V
V
Z
Z
W
W
81 (3.19)
51 (2.00)
30 (1.19)
97
(3.81)
51 (2.00)
3/4" or 1" NPT
internal pipe
(both ends)
Housing type
Models
WeatherproofFM (NEMA 7/9) ATEX (Cast Alu)
146
(5.75)
V
W
mm
inches
F10
257
10.12
F50
202
7.94
CENELEC (Cast Iron)
All
249
9.80
Pneumatics
Switch Module J
F10
216
8.50
F50
165
6.50
F10
216
8.50
F50
165
6.50
Pneumatics
Switch Module K
øX
1 1/2"or 2" NPT
internal pipe
(both ends)
Y
Z
mm
inches
mm
inches
mm
inches
42
1.66
151
5.93
109
4.29
M20 x 1,5 (*) or 1" NPT
(2 entries - 1 plugged)
(*) not for FM (NEMA 7/9)
45
1.77
143
5.63
110
4.33
M20 x 1,5 or 3/4" NPT
(single entry - 2 entries at request)
110
4.33
39
1.54
118
4.65
130
5.12
1/4" NPT
Allow 200 mm (7.87") overhead clearance / All housings are 360 ° rotatable
QUALITY ASSURANCE - ISO 9001
THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN,
THE CONSTRUCTION AND THE SERVICE OF CONTROLS.
OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE.
PRODUCT WARRANTY
ALL MAGNETROL MECHANICAL LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR FIVE
FULL YEARS FROM THE DATE OF ORIGINAL FACTORY SHIPMENT.
IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED
UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN
TRANSPORTATION.
MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION
OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME
MAGNETROL PRODUCTS.
BULLETIN N°:
EFFECTIVE:
SUPERSEDES:
UNDER RESERVE OF MODIFICATIONS
Heikensstraat 6, 9240 Zele, België
Tel. +32 (0)52.45.11.11 • Fax. +32 (0)52.45.09.93 • E-Mail: [email protected]
DEUTSCHLAND
Schloßstraße 76, D-51429 Bergisch Gladbach-Bensberg
Tel. 02204 / 9536-0 • Fax. 02204 / 9536-53 • E-Mail: [email protected]
FRANCE
Le Vinci 6 - Parc d’activités de Mitry Compans, 1, rue Becquerel, 77290 Mitry Mory
Tél. 01.60.93.99.50 • Fax. 01.60.93.99.51 • E-Mail: [email protected]
ITALIA
Via Arese 12, I-20159 Milano
Tel. (02) 607.22.98 (R.A.) • Fax. (02) 668.66.52 • E-Mail: [email protected]
UNITED
KINGDOM
Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL
Tel. (01444) 871313 • Fax (01444) 871317 • E-Mail: [email protected]
INDIA
B4/115 Safdurjung Enclave, New Delhi 110 029
Tel. 91 (11) 6186211 • Fax 91 (11) 6186418 • E-Mail: [email protected]
www.magnetrol.com
BENELUX
OUR NEAREST REPRESENTATIVE
BE 47-116.7
OCTOBER 2002
March 2002