F10 - F50 ® Flow Switches DESCRIPTION Standard & tailor made designs Magnetrol flow switches are highly reliable devices utilized to sense the start or stop of flow in horizontal pipelines containing oil and petroleum derivatives, chemicals, water, or air. Vane actuated model F10 switches are used on gas or liquid flow applications in 2" or larger pipe sizes. Disc actuated model F50 switches are in-line type used for sensing clean liquids in 2" or smaller pipe sizes. F E AT U R E S • Actuation on increasing or decreasing flow • Special sensing elements for non-standard or high flow applications • Designed for horizontal pipe applications • Standard anti corrosive protection Model F10: - Field adjustable - Low pressure drop - Process temperature up to +230 °C (+450 °F) - Process pressure up to 69 bar (1000 psi) - Standard flow vanes for 2" thru 10" flow lines Model F50: - No calibration required - Bronze or stainless steel construction - Process temperature up to +400 °C (+750 °F) - Process pressure up to 79,3 bar (1150 psi) - Bodies for flow lines from 3/4" to 2" F10 F50 A G E N C Y A P P R O VA L S Agency Approval ATEX II 2G EEx d II C T6, explosion proof II 1G EEx ia II C T6, intrinsically safe CENELEC CCE ➀ EEx d II C T6, explosion proof A P P L I C AT I O N S FM • • • • • • • • FM/CSA ➁ Class I, Div. 1, Groups C & D Class II, Div. 1, Groups E, F & G, Type NEMA 7/9 Non-Hazardous area Pump staging or failure Pipeline flow detection Valve failure Loss of pipeline flow Pipe blockage/rupture Pump inlet flow protection Check valve blockage/leakage Alarm on eyewash or shower safety station R1 (1) 136/MI/433, explosion proof Explosion proof area – Groups B, C, D, E, F & G Type NEMA 4X/7/9 SAA ➁ LRS Explosion proof area Lloyds Register of Shipment (marine applications) GOST/ GOSGORTECHNADZOR ➁ Russian Authorisation Standards Other approvals are available, consult factory for more details ➀ For CCE approved units, use the ATEX explosion proof model numbers. ➁ Consult factory for proper model numbers. Worldwide level and flow solutions P R I N C I P L E O F O P E R AT I O N F10 The actuating vane is magnetically linked to a pivoted electric (or pneumatic) switch, which is isolated from the process by a non-magnetic barrier tube. As the actuating vane moves with an increase in flow, it drives a magnetic sleeve into the field of a permanent magnet located outside the barrier tube which trips the switch. As flow decreases, the actuating vane returns to a vertical position, allowing the magnet and switch assembly to return to the “No Flow” position. Switch mechanism Adjusting screw Barrier tube (non magnetic) Magnetic sleeve Magnet Actuating vane No flow position Mechanism switch Pivot 4 5 Tension spring 6 Barrier tube (non magnetic) 4 5 6 Sleeve (magnetic) Swing out position Magnet Swing in position Flow disc No flow position Position with actuating flow present Position with actuating flow present F50 The rate of flow through the valve body raises or lowers the disc. This in turn raises or lowers the magnetic sleeve, within its sealed non-magnetic barrier tube. On an increasing flow rate, the magnetic sleeve rises into the field of the permanent magnet, located outside the barrier tube, actuating the attached switch mechanism. When the flow rate drops, below the rate for which the flow disc is calibrated, a reversal of this action occurs. MOUNTING FLOW Input line Additive flow Overflow detection FLOW Leak detection Overflow tank Pump protection FLOW Primary tank E L E C T R I C A L S P E C I F I C AT I O N S 2 Description Specification Switch ratings Up to 15 A @ 240 V AC (depending on switch mechanism) Up to 10 A @ 120 V DC (depending on switch mechanism) Signal Output Single SPDT or DPDT contacts or single pneumatic Switch Types (see table on page 3) Dry contact with standard or gold alloy contacts, Mercury, Hermetically sealed, Hermetically sealed with gold or silver plated contacts, Proximity switch, or single pneumatic bleed and non bleed Approvals (see table on page 1) ATEX II 2G EEx d II C T6, explosion proof ATEX II 1G EEx ia II C T6, intrinsically safe CENELEC EEx d II C T6, explosion proof FM/CSA/SAA, explosion proof LRS, Lloyds Register of Shipment (marine applications) GOST/GOSGORTECHNADZOR, Russian Authorisation standards Other approvals are available, consult factory. Cable entries M20 x 1,5 ISO, 1" NPT and 3/4" NPT (or others at request) AVA I L A B L E S W I T C H M E C H A N I S M S Max. Process Temp. ➁ Switch ratings – A res. ➂ ➄ F50 F10 24 V DC 240 V AC 120 V AC Micro switch max +120 °C (+250 °F) 6 15 15 Micro switch max +230 °C (+450 °F) 10 15 15 Micro switch - DC current max +120 °C (+250 °F) 10 – 10 Micro switch with gold alloy contacts max +120 °C (+250 °F) 1 – 1 Hermetically sealed micro switch max +230 °C (+450 °F) not applicable 5 5 5 Hermetically sealed micro switch with max +230 °C (+450 °F) 3 1 1 silver plated contacts Hermetically sealed micro switch with max +230 °C (+450 °F) 0,5 0,5 0,5 gold plated contacts Hermetically sealed micro switch not applicable max +400 °C (+750 °F) 4 – 2,5 Proximity switch - type SJ 3.5 SN max +100 °C (+210 °F) NA NA NA Mercury switch max +230 °C (+450 °F) max +290 °C (+500 °F) 10 6,5 13 Mercury switch not applicable max +400 °C (+750 °F) 10 6,5 13 Pneumatic bleed type (open air) max +200 °C (+400 °F) NA NA NA Pneumatic non bleed type max +200 °C (+400 °F) NA NA NA (closed circuit) Type of switch module ➀ ➀ ➁ ➂ ➃ ➄ Code B C D U HS ➃ W X F V A 3 J K For applications with heavy vibration, consult factory for suited switch modules. Max process temperature is specified at +40 °C (+100 °F) ambient temperature and for non condensing applications. For more details - see bulletin BE 42-120. For condensing applications, max process temperature is down-rated to +200 °C (+400 °F) @ +40 °C (+100 °F) ambient. For bronze construction, max process temperature is downrated to +260 °C (+500 °F). Type B, C, D & U Type HS Type F, W & X Type V Type A & 3 Type J & K AVA I L A B L E H O U S I N G S • • • • • For Non Ex use IP 66 Die cast Aluminium 2 Entries (one plugged) Standard blue anti corrosive coating • Housing heater/drain available, consult factory • • • • • For Exd/Exi use IP 66 Die cast Aluminium 2 Entries (one plugged) Standard blue anti corrosive coating • ATEX II 2G EEx d II C T6 • ATEX II 1G EEx ia II C T6 • • • • For Exd use IP 66 Cast Iron One entry (2 entries at request) • Standard blue anti corrosive coating • CENELEC EEx d II C T6 • • • • For pneumatic switches IP 53 (NEMA 3R) IP 55 optional at request Alu base / cold rolled steel cover • Standard blue anti corrosive coating • • • • • For Exd use IP 66 (NEMA 7/9) Die cast Aluminium 2 Entries (one plugged) Standard blue anti corrosive coating • FM, Class I, Div. 1, Groups C & D • FM, Class II, Div. 1, Groups E, F & G 3 S E L E C T I O N D ATA – F 1 0 Actuating flow rates (water service) – m3/h Model F10 units may be adjusted in service to actuate within the minimum and maximum flow rates given below (based on schedule 40 pipe). A specific gravity correction factor is applied for liquids other than water (1.00 specific gravity). Pipe size Flow increase Pipe size decrease Max. inches Flow increase decrease Specific gravity correction for actuating flow rates – m3/h To determine the actuating flow rates for liquids other than water (approximate viscosity of 20 cP or less) a specific gravity correction factor must be applied to the water flow rates given in the table. Specific Gravity Multiplication Factor Specific Gravity Multiplication Factor inches Min. Max. Min. Min. Max. Min. Max. 0.40 1.58 0.95 1.03 2.00 4.8 14.3 3.6 10.9 14.00 61.3 97.6 38.6 63.6 0.45 1.49 1.00 1.00 2.50 5.2 16.8 4.5 12.7 16.00 77.2 115.8 49.9 72.6 0.50 1.41 1.05 0.98 3.00 7.3 20.0 5.4 14.8 18.00 97.6 133.9 61.3 84.0 0.55 1.35 1.10 0.95 3.50 8.6 22.7 6.4 17.0 20.00 118.0 156.6 72.6 97.6 0.60 1.29 1.15 0.93 4.00 10.2 27.2 7.5 19.3 22.00 140.7 177.1 86.3 109.0 0.65 1.24 1.20 0.91 5.00 13.8 34.1 9.8 25.0 24.00 165.7 204.3 102.2 124.9 0.70 1.20 1.25 0.89 6.00 17.9 40.9 12.5 29.5 26.00 193.0 233.8 118.0 140.7 0.75 1.15 1.30 0.88 8.00 27.2 52.2 18.6 36.3 28.00 222.5 263.3 133.9 158.9 0.80 1.12 1.35 0.86 10.00 38.6 70.4 25.0 47.7 30.00 252.0 292.8 152.1 177.1 0.85 1.08 1.40 0.85 12.00 52.2 86.3 34.1 56.8 0.90 1.05 1.45 0.83 For higher/lower flow rates, consult factory. P H Y S I C A L S P E C I F I C AT I O N S – F 1 0 Description Specification Measured variable Physical range Flow rate Increasing flow From 4,8 m3/h (2" pipe size) up to 292,8 m3/h (30" pipe size) Decreasing flow From 3,6 m3/h (2" pipe size) up to 177,1 m3/h (30" pipe size) Process temperature Process pressure (for higher ratings consult factory) Up to 69 bar @ +230 °C (1000 psi @ +450 °F) Process connection material Carbon steel or stainless steel Wetted materials Vane and trim 302 SST (1.4300) and 316 SST (1.4401) Magnetic sleeve 316 SST (1.4401) EXPEDITE SHIP PLAN (ESP) Several mechanical switches are available for quick shipment, within max. 3 weeks after factory receipt of purchase order, through the Expedite Ship Plan (ESP). Models covered by ESP service are conveniently grey coded in the selection data charts. To take advantage of ESP, simply match the grey coded model number codes (standard dimensions apply). ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume orders, as well as other products and options. S E L E C T I O N D ATA – F 1 0 Select pneumatic switch mechanism & enclosure Pneumatic switch type Series J (open air) Series K (closed circuit) 4 Max supply pressure bar (psi) Max liquid temperature °C (°F) Bleed orifice Ø mm (inches) NEMA 3R (IP 53) 6,9 (100) +200 (+400) 1,60 (0.063) JGF 4,1 (60) +200 (+400) 2,39 (0.094) JHF 6,9 (100) +200 (+400) – KOF S E L E C T I O N D ATA – F 1 0 A complete measuring system consists of: 1. Order code for F10 models 2. Order code for modified models or adders: put an "X" in front of the closest matching order code and specify the modifications/adders separately eg. XF10-AD22-BK9 X = with material certification EN 10204 / DIN 50049-3.1.B 1. Order code for F10 flow switch BASIC MODEL NUMBER F 1 0 vane actuated flow switch – field adjustable setpoint MATERIALS OF CONSTRUCTION D 316 SST (1.4401) Code A Process connection material Carbon steel Vane and trim Magnetic sleeve 302 SST (1.4300) & 316 SST (1.4401) 316 SST (1.4401) PIPE SIZE AND PROCESS CONNECTION Pipe size Process connection Pipe size Process connection D 2 2 2" 2" NPT E 6 4 4" 2 1/2" - 300 lbs RF D 2 4 4" 2" NPT E 6 6 6" 2 1/2" - 300 lbs RF D 2 6 6" 2" NPT E 6 8 8" 2 1/2" - 300 lbs RF D 2 8 8" 2" NPT E 6 0 10" 2 1/2" - 300 lbs RF D 2 0 10" 2" NPT E 5 4 4" 2 - 150 lbs RF E 7 4 4" 2 1/2" - 600 lbs RF E 5 6 6" 2 1/2" - 150 lbs RF E 7 6 6" 2 1/2" - 600 lbs RF - 150 lbs RF E 7 8 8" 2 1/2" - 600 lbs RF 2 1/2" - 150 lbs RF E 7 0 10" 2 1/2" - 600 lbs RF E 5 8 8" E 5 0 10" 2 1/2" 1/2" SWITCH MECHANISM & ENCLOSURE - for electric switch mechanisms (see below) - for pneumatic switch mechanisms (see left page) complete order code for F10 models F 1 0 Select electric switch mechanism & enclosure qty and switch type A B C D HS U V W X Weather proof (IP 66) CENELEC (IP 66) FM (IP 66) II 2G EEx d II C T6 II 1G EEx ia II C T6 EEx d II C T6 NEMA 7/9 cast Aluminium cast Aluminium cast Aluminium cast Iron cast Alu. ATEX (IP 66) M20 x 1,5 1" NPT M20 x 1,5 1" NPT M20 x 1,5 1" NPT M20 x 1,5 3/4" NPT 1 x SPDT A2B AAB AK9 AC9 – – AK5 AU5 1" NPT AKB 1 x DPDT A8B ADB AN9 AF9 – – AD5 AW5 ANB 1 x SPDT B2B BAB BK9 BC9 – – BK5 BU5 BKB 1 x DPDT B8B BDB BN9 BF9 – – BD5 BW5 BNB 1 x SPDT C2B CAB CK9 CC9 C2T CAT CK5 CU5 CKB 1 x DPDT C8B CDB CN9 CF9 C8T CDT CD5 CW5 CNB 1 x SPDT D2B DAB DK9 DC9 – – DK5 DU5 DKB 1 x DPDT D8B DDB DN9 DF9 – – DD5 DW5 DNB 1 x SPDT H7A HM2 HFC HA9 – – HB3 HB4 HM3 1 x DPDT H7C HM6 HGC HB9 – – HB7 HB8 HM7 1 x SPDT U2B UAB UK9 UC9 U2T UAT UK5 UU5 UKB 1 x DPDT U8B UDB UN9 UF9 U8T UDT UD5 UW5 UNB – – – – – VCS VES – – – 1 x SPDT W2B WAB WK9 WC9 W2T WAT WK5 WU5 WKB 1 x DPDT W8B WDB WN9 WF9 W8T WDT WD5 WW5 WNB 1 x SPDT X2B XAB XK9 XC9 X2T XAT XK5 XU5 XKB 1 x DPDT X8B XDB XN9 XF9 X8T XDT XD5 XW5 XNB 5 S E L E C T I O N D ATA – F 5 0 Specific gravity correction for actuating flow rates – m3/h To determine the actuating flow rates for liquids other than water (approximate viscosity of 20 cP or less), a specific gravity correction factor must be applied to the water flow rates given in the table. For gas/air applications, consult factory. Specific Gravity Multiplication Factor Specific Gravity Multiplication Factor 0.40 1.58 0.95 1.03 0.45 1.49 1.00 1.00 0.50 1.41 1.05 0.98 0.55 1.35 1.10 0.95 0.60 1.29 1.15 0.93 0.65 1.24 1.20 0.91 0.70 1.20 1.25 0.89 0.75 1.15 1.30 0.88 0.80 1.12 1.35 0.86 0.85 1.08 1.40 0.85 0.90 1.05 1.45 0.83 1400 1400 1200 1200 pressure drop in mbar pressure drop in mbar P R E S S U R E D R O P TA B L E S – F 5 0 1000 800 600 400 200 1000 800 600 400 200 0 0 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 0 0,5 1 1,5 2 2,5 3 3,5 3/4" NPT connection 4,5 5 5,5 6 6,5 32 34 7 7,5 8 1" NPT connection 1400 pressure drop in mbar 1400 pressure drop in mbar 4 flow in m3/h flow in m3/h 1200 1000 800 600 400 200 1200 1000 800 600 400 200 0 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 0 2 4 6 8 10 12 flow in m3/h 14 16 18 20 22 24 26 28 30 36 38 40 42 flow in m3/h 11/2" NPT connection 2" NPT connection P H Y S I C A L S P E C I F I C AT I O N S – F 5 0 Description Specification Measured variable Flow rate Physical range Process temperature Process pressure (for higher ratings consult factory) Increasing flow From 0,25 m3/h (3/4" pipe size) up to 5,63 m3/h (2" pipe size) Decreasing flow From 0,18 m3/h (3/4" pipe size) up to 4,77 m3/h (2" pipe size) Bronze models Up to 27,6 bar @ +40 °C (400 psi @ +100 °F) Up to +260 °C @ 13,8 bar (+500 °F @ 200 psi) Stainless steel models Up to 79,3 bar @ +40 °C (1150 psi @ +100 °F) Up to +400 °C @ 41,3 bar (+750 °F @ 600 psi) Body material Wetted materials Bronze or stainless steel Disc and trim 316 SST (1.4401) Magnetic sleeve 316 SST (1.4401) or 400 series SST S E L E C T I O N D ATA – F 5 0 Select pneumatic switch mechanism & enclosure Max supply pressure bar (psi) Max liquid temperature °C (°F) Bleed orifice Ø mm (inches) Series J (open air) 6,9 (100) +200 (+400) 1,60 (0.063) JDG JDE 4,1 (60) +200 (+400) 2,39 (0.094) Series K (closed circuit) 6,9 (100) +200 (+400) – JEG KOE➁ KOE 2,8 (40) +200 (+400) – KOG – ➀ Use switch codes with material code D for F50-AC2E / F50-AC2F / F50-AD2E / F50-AD2F ➁ Only in combination with F50-AC2E / F50-AC2F / F50-AD2E / F50-AD2F 6 NEMA 3R (IP 53) material code D material code A ➀ Pneumatic switch type JEE S E L E C T I O N D ATA – F 5 0 A complete measuring system consists of: 1. Order code for F50 models. 2. Order code for modified models or adders: put an "X" in front of the closest matching order code and specify the modifications/adders separately eg. XF50-AB2C-A2P X = process connection 1" - 150 lbs RF ANSI flanges 1. Order code for F50 flow switch BASIC MODEL NUMBER F 5 0 mechanical disc actuated flow switch Code MATERIALS OF CONSTRUCTION Body material A Bronze & carbon steel nut 300 series SST 400 series SST D 316 SST (1.4401) 316 SST (1.4401) 316 SST (1.4401) Flow disc and trim Magnetic sleeve PROCESS CONNECTION AND ACTUATING FLOW RATES Actuating flow rate Process connection Actuating flow rate Process connection increasing decreasing increasing decreasing NPT 0,25 m3/h 0,18 m3/h C 2 A 11/2" NPT 0,30 m /h 0,25 m3/h A 2 C 3/4" NPT 0,36 m /h 0,27 m /h C 2 B 11/2" NPT 0,61 m /h 0,52 m3/h A 2 D 3/4" NPT 0,52 m3/h 0,41 m3/h C 2 C 11/2" NPT 1,07 m3/h 0,91 m3/h A 2 E 3/4" NPT 0,77 m /h 0,59 m /h C 2 D 11/2" NPT 1,73 m /h 1,48 m3/h A 2 F 3/4" NPT 1,11 m3/h 0,84 m3/h C 2 E 11/2" NPT 2,79 m3/h 2,38 m3/h B 2 A 1" NPT 0,23 m /h 0,18 m /h C 2 F 11/2" NPT 4,79 m3/h 4,06 m3/h B 2 B 1" NPT 0,39 m /h 0,32 m /h D 2 A 2" NPT 0,43 m /h 0,36 m3/h B 2 C 1" NPT 0,57 m /h 0,48 m /h D 2 B 2" NPT 0,70 m3/h 0,61 m3/h B 2 D 1" NPT 0,84 m /h 0,68 m /h D 2 C 2" NPT 1,16 m /h 0,98 m3/h B 2 E 1" NPT 1,25 m3/h 1,02 m3/h D 2 D 2" NPT 1,91 m3/h 1,61 m3/h B 2 F 1" NPT 1,61 m /h 1,32 m /h D 2 E 2" NPT 3,25 m /h 2,75 m3/h D 2 F 2" NPT 5,63 m3/h 4,77 m3/h A 2 B 3/4" 3 3 3 3 3 3 3 3 3 3 3 3 3 3 SWITCH MECHANISM & ENCLOSURE F 5 0 3 3 3 3 3 3 - for electric switch mechanisms (see below) - for pneumatic switch mechanisms (see left page) complete order code for F50 models 2 Select electric switch mechanism & enclosure All models with material code A ➀ qty and switch type A 3 B C D F U V W X Weather proof (IP 66) cast Aluminium All models with material code D ATEX (IP 66) CENELEC (IP 66) FM (IP 66) II 2G EEx d IIC T6 II 1G EEx ia II C T6 EEx d IIC T6 NEMA 7/9 Weather proof (IP 66) cast Iron cast Alu. cast Aluminium M20 x 1,5 3/4" NPT cast Aluminium cast Aluminium ATEX (IP 66) CENELEC (IP 66) II 2G EEx d IIC T6 II 1G EEx ia II C T6 EEx d IIC T6 NEMA 7/9 cast Iron cast Alu. M20 x 1,5 3/4" NPT 1" NPT cast Aluminium cast Aluminium FM (IP 66) M20 x 1,5 1" NPT M20 x 1,5 1" NPT M20 x 1,5 1" NPT 1" NPT M20 x 1,5 1" NPT M20 x 1,5 1" NPT M20 x 1,5 1" NPT 1 x SPDT A2P AAP AHC AAC - - AK7 AU7 AKP A2Q AAQ AH9 AA9 - - AK5 AU5 AKQ 1 x DPDT A8P ADP AJC ABC - - AD7 AW7 ANP A8Q ADQ AJ9 AB9 - - AD5 AW5 ANQ 1 x SPDT 32P 3AP 3HC 3AC - - 3K7 3U7 3KP 32Q 3AQ 3H9 3A9 - - 3K5 3U5 3KQ 1 x DPDT 38P 3DP 3JC 3BC - - 3D7 3W7 3NP 38Q 3DQ 3J9 3B9 - - 3D5 3W5 3NQ 1 x SPDT B2P BAP BHC BAC - - BK7 BU7 BKP B2Q BAQ BH9 BA9 - - BK5 BU5 BKQ 1 x DPDT B8P BDP BJC BBC - - BD7 BW7 BNP B8Q BDQ BJ9 BB9 - - BD5 BW5 BNQ 1 x SPDT C2P CAP CHC CAC C2L CAL CK7 CU7 CKP C2Q CAQ CH9 CA9 C2S CAS CK5 CU5 CKQ 1 x DPDT C8P CDP CJC CBC C8L CDL CD7 CW7 CNP C8Q CDQ CJ9 CB9 C8S CDS CD5 CW5 CNQ 1 x SPDT - - - - - - - - - D2Q DAQ DH9 DA9 - - DK5 DU5 DKQ 1 x DPDT - - - - - - - - - D8Q DDQ DJ9 DB9 - - DD5 DW5 DNQ 1 x SPDT F2P FAP FHC FAC - - FK7 FU7 FKP F2Q FAQ FH9 FA9 - - FK5 FU5 FKQ 1 x DPDT F8P FDP FJC FBC - - FD7 FW7 FNP F8Q FDQ FJ9 FB9 - - FD5 FW5 FNQ 1 x SPDT U2P UAP UHC UAC U2L UAL UK7 UU7 UKP U2Q UAQ UH9 UA9 U2S UAS UK5 UU5 UKQ 1 x DPDT U8P UDP UJC UBC U8L UDL UD7 UW7 UNP U8Q UDQ UJ9 UB9 U8S UDS UD5 UW5 UNQ - - - - - VFS VHS - - - - - - - V5S VBS - - - 1 x SPDT W2P WAP WHC WAC W2L WAL WK7 WU7 WKP W2Q WAQ WH9 WA9 W2S WAS WK5 WU5 WKQ WNQ 1 x DPDT - - - - - - - - - W8Q WDQ WJ9 WB9 W8S WDS WD5 WW5 1 x SPDT X2P XAP XHC XAC X2L XAL XK7 XU7 XKP X2Q XAQ XH9 XA9 X2S XAS XK5 XU5 XKQ 1 x DPDT - - - - - - - - - X8Q XDQ XJ9 XB9 X8S XDS XD5 XW5 XNQ ➀ Use switch codes with material code D for F50-AC2E / F50-AC2F / F50-AD2E / F50-AD2F 7 DIMENSIONS in mm (inches) X Pipe size Dim. A max. 2" Equivalent max. wall schedule X Y Y Dim. B 46 (1.81) 180 40 (1.59) 2 1/2" 49 (1.94) 160 53 (2.09) 3" 48 (1.88) 180 68 (2.66) 3 1/2" 48 (1.88) 180 79 (3.12) 4" 51 (2.00) 120 94 (3.69) 5" 52 (2.06) 120 118 (4.66) 6" 54 (2.12) 120 145 (5.72) 8" 56 (2.19) 100 195 (7.69) 10" 59 (2.31) 100 254 (10.00) V 2" NPT W 2" NPT 3000# bonney threadolet or equal (supplied by customer) FLOW over 10" 59 (2.31) V Z Z 63 (2.50) A W 133 (5.25) 187 (7.38) Dim "B" 44 (1.75) Pipe size (horizontal lines only) 3" pipe and up Vane width 38 (1.50) 65 ø ± 1,5 (2.56 ø ± 0.06) 76 ø (3.00) 5 (0.19) minimum Flow vane 2" and 2 1/2" pipe Y Y X X V V Z Z W W 81 (3.19) 51 (2.00) 30 (1.19) 97 (3.81) 51 (2.00) 3/4" or 1" NPT internal pipe (both ends) Housing type Models WeatherproofFM (NEMA 7/9) ATEX (Cast Alu) 146 (5.75) V W mm inches F10 257 10.12 F50 202 7.94 CENELEC (Cast Iron) All 249 9.80 Pneumatics Switch Module J F10 216 8.50 F50 165 6.50 F10 216 8.50 F50 165 6.50 Pneumatics Switch Module K øX 1 1/2"or 2" NPT internal pipe (both ends) Y Z mm inches mm inches mm inches 42 1.66 151 5.93 109 4.29 M20 x 1,5 (*) or 1" NPT (2 entries - 1 plugged) (*) not for FM (NEMA 7/9) 45 1.77 143 5.63 110 4.33 M20 x 1,5 or 3/4" NPT (single entry - 2 entries at request) 110 4.33 39 1.54 118 4.65 130 5.12 1/4" NPT Allow 200 mm (7.87") overhead clearance / All housings are 360 ° rotatable QUALITY ASSURANCE - ISO 9001 THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN, THE CONSTRUCTION AND THE SERVICE OF CONTROLS. OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE. PRODUCT WARRANTY ALL MAGNETROL MECHANICAL LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR FIVE FULL YEARS FROM THE DATE OF ORIGINAL FACTORY SHIPMENT. IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN TRANSPORTATION. MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME MAGNETROL PRODUCTS. BULLETIN N°: EFFECTIVE: SUPERSEDES: UNDER RESERVE OF MODIFICATIONS Heikensstraat 6, 9240 Zele, België Tel. +32 (0)52.45.11.11 • Fax. +32 (0)52.45.09.93 • E-Mail: [email protected] DEUTSCHLAND Schloßstraße 76, D-51429 Bergisch Gladbach-Bensberg Tel. 02204 / 9536-0 • Fax. 02204 / 9536-53 • E-Mail: [email protected] FRANCE Le Vinci 6 - Parc d’activités de Mitry Compans, 1, rue Becquerel, 77290 Mitry Mory Tél. 01.60.93.99.50 • Fax. 01.60.93.99.51 • E-Mail: [email protected] ITALIA Via Arese 12, I-20159 Milano Tel. (02) 607.22.98 (R.A.) • Fax. (02) 668.66.52 • E-Mail: [email protected] UNITED KINGDOM Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL Tel. (01444) 871313 • Fax (01444) 871317 • E-Mail: [email protected] INDIA B4/115 Safdurjung Enclave, New Delhi 110 029 Tel. 91 (11) 6186211 • Fax 91 (11) 6186418 • E-Mail: [email protected] www.magnetrol.com BENELUX OUR NEAREST REPRESENTATIVE BE 47-116.7 OCTOBER 2002 March 2002