Test Report 1. Date: 2011/10/24 2. Place: QA Lab. 3. Product: MTP10016A(3Ø Bridge, 100A/1600V), 2pcs 4. Test item: Intermittent Operation Life 5. Testing method and condition: (Test circuit as below) A). 2 modules in series connection. B). Apply DC current, 100A C). A cycle: Power on when temp. of base plate reach to 100°C → → power on again → power off, cooling down to 40°C D). Duration: 1000 cycles. 6. Testing equipment and tool: DC power supply, Temperature controller, thermal couple, heat sink, fan, counter. 7. Test data brfore testing: VISO= 3000VAC x 60S Item Test condition VRRM 1600V VFM @ IF=100A 1.212V VRRM 1600V TA=150°C IRRM 1.15mA VRRM 1600V TA=25°C VFM @ IF=100A 1.221V VRRM 1600V TA=150°C IRRM 1.12mA TA=25°C 1 2 D1 D2 D3 D4 D5 D6 1600V 1.165V 1600V 1.11mA 1600V 1.166V 1600V 0.95mA 1600V 1.181V 1600V 1.27mA 1600V 1.189V 1600V 0.94mA 1600V 1.205V 1600V 1.16mA 1600V 1.210V 1600V 0.89mA 1600V 1.178V 1600V 1.35mA 1600V 1.174V 1600V 1.13mA 1600V 1.161V 1600V 1.33mA 1600V 1.185V 1600V 0.87mA 第 1 頁,共 2 頁 VISO 0.16mA 0.18mA 8. Test duration: 1000 cycles 9. Test data after testing: VISO= 3000VAC x 60S Item Test condition D1 VRRM 1600V VFM @ IF=100A 1.214V VRRM 1600V TA=150°C IRRM 1.11mA VRRM 1600V TA=25°C VFM @ IF=100A 1.222V 1600V VRRM TA=150°C IRRM 1.07mA TA=25°C 1 2 D2 D3 D4 D5 D6 1600V 1.162V 1600V 1.34mA 1600V 1.175V 1600V 0.91mA 1600V 1.181V 1600V 1.20mA 1600V 1.193V 1600V 0.92mA 1600V 1.216V 1600V 1.10mA 1600V 1.221V 1600V 0.89mA 1600V 1.188V 1600V 1.30mA 1600V 1.187V 1600V 1.15mA 1600V 1.191V 1600V 1.26mA 1600V 1.195V 1600V 0.88mA VISO 0.14mA 0.15mA 10. Test result: All the test samples are eligible after 1000 cycles of Intermittent Operation Life test. Tested by: Rex Cheched By: Smart 第 2 頁,共 2 頁