Single Interleave Designs - Maximum Height 7.4mm
Turns
Part #
SX55-1-4444
SX55-1-5544
SX55-1-6644
SX55-1-7744
SX55-1-8844
SX55-1-4477
SX55-1-5577
SX55-1-6677
SX55-1-7777
SX55-1-8877
SX55-1-4411
SX55-1-5511
SX55-1-6611
SX55-1-7711
SX55-1-8811
SX55-1-4421
SX55-1-5521
SX55-1-6621
SX55-1-7721
SX55-1-8821
PRI
4T
5T
6T
7T
8T
4T
5T
6T
7T
8T
4T
5T
6T
7T
8T
4T
5T
6T
7T
8T
Sec.
4T
1T & 1T
1T & 1T
7T & 7T
1T & 1T
2T & 1T
Primary*
Inductance
(µH Min.)
54
85
120
165
215
54
85
120
165
215
54
85
120
165
215
54
85
120
165
215
Leakage**
Inductance
(µH Nom)
0.15
0.18
0.22
0.28
0.33
0.15
0.18
0.22
0.28
0.33
0.15
0.18
0.22
0.28
0.33
0.15
0.18
0.22
0.28
0.33
DCR (mΩ Nom)
PRI
7
12
17
25
32
7
12
17
25
32
7
12
17
25
32
7
12
17
25
32
Sec.
Sch.
7.00
B1
46 &46
B2
0.9 & 0.9
B2
4&1
B3
* Inductance is measured with primary winding (2 to 4).
**Leakage inductance is measured on winding (2 – 4) with all other windings shorted.
Double Interleave Designs - Maximum Height 10.2mm
Turns
Part #
SX55-2-4444
SX55-2-5544
SX55-2-6644
SX55-2-7744
SX55-2-8844
SX55-2-4411
SX55-2-5511
SX55-2-6611
SX55-2-7711
SX55-2-8811
PRI A
PRI B
4T
5T
6T
7T
8T
4T
5T
6T
7T
8T
4T
5T
6T
7T
8T
4T
5T
6T
7T
8T
Sec.
4T
1T & 1T
1T & 1T
1T & 1T
Primary*
Inductance
(µH Min.)
216
340
480
660
860
216
340
480
660
860
Leakage**
Inductance
(µH Nom)
0.100
0.150
0.180
0.250
0.280
0.100
0.150
0.180
0.250
0.280
DCR (mΩ Nom)
PRI A
PRI B
7
12
17
25
32
7
12
17
25
32
7
12
17
25
32
7
12
17
25
32
Sec.
Sch.
3.50
A1
0.45 & 0.45
A2
* Inductance is measured with both primary windings connected in series (2 to 5, with 3 and 4 shorted).
**Leakage inductance is measured on winding (2 – 5) connected in series with all other windings shorted.
PS_PlanarSX55 11.242
www.standexelectronics.com • +1.866.STANDEX (+1.866.782.6339)
United Kingdom +44.1732.771.023 • China +86.22.86996881~5
Call today to find out why
Standex is a world leader in
planar transformer technology!
Core Loss vs Flux Density
An Engineered Solution Provider and
Manufacturer of Custom Components & Assemblies
SX-55 Series 350W/700W
Mechanical Dimensions
Core Loss Vs Flux Density
26.00mm Max
3
7
.005 0.13
Core Loss (Watts)
11
30.00mm Max
1
1
6
11
1
Flux (Gauss)
Temperature Rise
100
90
80
70
60
50
40
30
20
10
0
7
25.40mm
1
2
H
H = Maximum Height
See Table on Front
Suggested Pad Layout
03.30mm
15.24mm
7.62mm
12.70mm
100 Khz
200 Khz
300 Khz
400 Khz
6
6.35mm
15.88mm
02.79mm
Total Loss
Schematics
Double Interleave
Single Interleave
B1
11
1T
2
PRI B
4
1
PRI AUX
(OPTIONAL)
6
1T
1T
1T
10
9
8
7
B2
2
PRI B
4
1
PRI AUX
(OPTIONAL)
6
B3
11
XT
XT
10
8
11
1T
2
PRI B
4
1
7 PRI AUX
(OPTIONAL)
6
10
9
1T
1T
8
7
A1
2
4
3
PRI B
11
1T
1T
PRI A
5
1
PRI AUX
(OPTIONAL)
6
1T
1T
10
9
8
7
A2
2
11
PRI B
1T
PRI A
5
1
PRI AUX
(OPTIONAL)
6
1T
4
3
10
8
7
Call Standex for all of your
Planar transformer needs!
www.standexelectronics.com • +1.866.STANDEX (+1.866.782.6339)
United Kingdom +44.1732.771.023 • China +86.22.86996881~5