SX40 Series Planar Transformers With Power Ratings To 180W/360W

An Engineered Solution Provider and
Manufacturer of Custom Components & Assemblies
Product Solutions
SX40 Series
Planar Transformers
With Power Ratings To
180W/360W
New SX40 series Hi-Power Planar
Transformers from Standex Electronics
feature high performance from a
compact, low-profile package. These
proven designs are ideal for demanding
applications where space and weight
savings are vital. Applications such
as military, aerospace, hybrid vehicles
and alternative energy can benefit
from these standard or custom Standex
planar designs.
Single Interleave Designs - Maximum Height 7.4mm
Primary*
Turns
Inductance
Part #
PRI A PRI B
Sec.
(µH Min.)
Leakage**
Inductance
(µH Nom)
SX40-1-3444
3T
4T
117
0.15
SX40-1-4444
4T
4T
153
0.20
SX40-1-4544
4T
5T
194
0.25
4T
SX40-1-5544
5T
5T
240
0.30
SX40-1-5644
5T
6T
290
0.35
SX40-1-6644
6T
6T
345
0.40
SX40-1-3411
3T
4T
117
0.15
SX40-1-4411
4T
4T
153
0.20
SX40-1-4511
4T
5T
194
0.25
1T & 1T
SX40-1-5511
5T
5T
240
0.30
SX40-1-5611
5T
6T
290
0.35
SX40-1-6611
6T
6T
345
0.40
SX40-1-3421
3T
4T
117
0.15
SX40-1-4421
4T
4T
153
0.20
SX40-1-4521
4T
5T
194
0.25
2T & 1T
SX40-1-5521
5T
5T
240
0.30
SX40-1-5621
5T
6T
290
0.35
SX40-1-6621
6T
6T
345
0.40
SX40-1-4431
4T
4T
153
0.20
3T & 1T
SX40-1-4531
4T
5T
194
0.30
* Inductance is measured with primary winding (2 to 4).
**Leakage inductance is measured on winding (2 – 4) with all other windings shorted.
Double Interleave Designs - Maximum Height 9.8mm
Primary*
Turns
Inductance
Part #
PRI A PRI B
Sec.
(µH Min.)
SX40-2-3444
SX40-2-4444
SX40-2-4544
SX40-2-5544
SX40-2-5644
SX40-2-6644
SX40-2-3411
SX40-2-4411
SX40-2-4511
SX40-2-5511
SX40-2-5611
SX40-2-6611
SX40-2-3421
SX40-2-4421
SX40-2-4521
SX40-2-5521
SX40-2-5621
SX40-2-6621
SX40-2-4431
SX40-2-4531
3T
4T
4T
5T
5T
6T
3T
4T
4T
5T
5T
6T
3T
4T
4T
5T
5T
6T
4T
4T
4T
4T
5T
5T
6T
6T
4T
4T
5T
5T
6T
6T
4T
4T
5T
5T
6T
6T
4T
5T
4T
(1T:1T:1T:1T)
1T & 1T
2T & 1T
3T & 1T
117
153
194
240
290
345
117
153
194
240
290
345
117
153
194
240
290
345
153
194
DCR (mΩ Nom)
PRI A
PRI B
9
15
15
26
26
36
9
15
15
26
26
36
9
15
15
26
26
36
15
15
15
15
26
26
36
36
15
15
26
26
36
36
15
15
26
26
36
36
15
26
Leakage**
Inductance
(µH Nom)
PRI A
PRI B
0.100
0.100
0.100
0.150
0.150
0.150
0.100
0.100
0.100
0.150
0.150
0.150
0.100
0.100
0.100
0.150
0.150
0.150
0.100
0.100
5
8
8
14
14
19
5
8
8
14
14
19
5
8
8
14
14
19
8
8
8
8
14
14
19
19
8
8
14
14
19
19
8
8
14
14
19
19
8
14
Sec.
Sch.
7.00
A1
1&1
A2
4&1
A3
9&1
A3
DCR (mΩ Nom)
Sec.
Sch.
4.00
A1
0.6 & 0.6
A2
1.7 & 0.6
A3
5 & 0.6
A3
* Inductance is measured with both primary windings connected in series (2 to 5, with 3 and 4 shorted).
**Leakage inductance is measured on winding (2 – 5) connected in series with all other windings shorted.
PS_PlanarSX40 11.242
www.standexelectronics.com • +1.866.STANDEX (+1.866.782.6339)
United Kingdom +44.1732.771.023 • China +86.22.86996881~5
Call today to find out why
Standex is a world leader in
planar transformer technology!
An Engineered Solution Provider and
Manufacturer of Custom Components & Assemblies
SX-40 Series 180W/360W
Mechanical Dimensions
Core Loss Vs Flux Density
21.20mm Max
7
.005 0.13
Core Loss (Watts)
11
2
1.87
1.73
1.6
1.47
1.33
1.2
1.07
0.93
0.8
0.67
0.53
0.4
0.27
0.13
23.30mm Max
1
H
H = Maximum Height
See Table on Front
6
Flux (Gauss)
Suggested Pad Layout
02.79mm
100 Khz
200 Khz
300 Khz
400 Khz
Temperature Rise
12.70mm
6.35mm
120
100
80
10.16mm
60
20.32mm
40
20
0
4.57mm
10.16mm
15.75mm
02.03mm
Total Loss
Schematics
A1
2
4
3
PRI B
11
PRI A
5
1
PRI AUX
(OPTIONAL)
6
A2
2
4T
7
4
3
PRI B
1T
PRI A
1T
5
1
PRI AUX
(OPTIONAL)
6
11
2
10
8
4
3
7
A3
PRI B
11
1T
9
PRI A
5
1
PRI AUX
(OPTIONAL)
6
10
XT
7
Call Standex for all of your
Planar transformer needs!
www.standexelectronics.com • +1.866.STANDEX (+1.866.782.6339)
United Kingdom +44.1732.771.023 • China +86.22.86996881~5