RP2E Compact pressure switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Resistant to accidental overpressure Explosion proof Hazardous areas 1, 2, 21, 22 Applications Pneumatic appliances Power generation safety equipment Water treatment Valve and compressor control Technical Data Pressure range 0 ... 1 bar to 0 ... 100 bar Temperature Process : Ambient : Storage : -40 ... +150°C -20 ... +70°C (T5) -20 ... +60°C (T6) -40 ... +70°C Repeatability ± 1% F.S. @ constant pressure cycle CE conformity Low Voltage Directive LVD 2006/95/EC Pressure Equipment Directive PED 97/23/EC ATEX Directive 94/9/EC Protection rating IP 66 (EN 60529) Process Connection Stainless steel 1.4404 (316L) Diaphragm Stainless steel 1.4404 (316L) Scale Internal graduated scale Weight 1.8 kg Housing Grey painted aluminium housing Explosion proof Mounting 2 x M6x16 screws Ground connection Via internal or external terminal block Electrical connection Via internal terminal block with cable gland 3/4 NPT (ATEX certified) for cable Ø 7 to 12 mm Electrical function See ordering code details on page 4 Adjustment Internal adjustment possible for set point and dead band Type examination certificate LCIE 02 ATEX 6219X EN 60079-0: 2012 (internal conformity analysis) EN 60079-1: 2007 EN 60079-31: 2009 Marking 0081 II 2 G D Ex d IIC T6 or T5 Gb Ex t IIIC IIC T80°C or T95°C Db IP6X ATEX Code SETP Oxygen application Code 0765 Mounting on 2" pipe Code 0407 Stainless steel tag plate and wire Code 9941 2015-04-21 Customer specific set point adjustment Design and specifications subject to change without notice Options www.baumer.com Data sheet A32.02 Page 1 / 4 RP2E Compact pressure switch Explosion proof Principle A flexible sensing element actuates a microswitch by means of a piston. The set point is adjusted by means of a compressible spring installed in opposition. NC NC NC C C C NO NO P NO Set point and reset point must be between 10% and 90% of the selected scale. Standard factory adjustment Setpoint at 50% of the scale on falling pressure NC C NC NC C C NO Customer speciffic factory adjustment (option SETP) The following specifications have to be given with the order: • Setpoint value • Adjustment on falling or raising pressure • Dead band value when using an adjustable dead band switch NO NO Adjustable ranges Micro-switch dead band 1) Adjustable dead band Code bar bar bar 41 Fixed dead band R L M-N-P U (2xSPDT) 10% 90% 10% 90% 10% 90% 10% 90% mbar mbar mbar mbar mbar mbar mbar mbar N/A N/A 30 60 120 330 150 300 0 ... 1 0 ... 1.6 42 100 - 200 200 - 550 35 70 150 390 175 350 43 125 - 230 250 - 700 40 80 180 480 200 400 44 150 - 290 320 - 900 45 90 210 540 225 450 0 ... 2.5 0 ... 4 0 ... 10 50 6 45 190 - 350 420 - 1200 50 100 240 630 250 500 0 ... 10 46 260 - 500 600 - 1800 55 110 300 750 275 550 0 ... 4 51 500 - 1000 1250 - 2000 110 200 600 1320 550 1000 0 ... 6 52 550 - 1100 1350 - 2200 110 235 750 1620 550 1175 0 ... 10 53 650 - 1300 1500 - 2600 120 270 840 2010 600 1350 54 800 - 1600 1700 - 3100 130 305 960 2370 650 1525 40 100 0 ... 16 0 ... 25 55 1000 - 2000 2000 - 3900 140 340 1050 2730 700 1700 0 ... 40 56 1400 - 2800 2600 - 5200 150 380 1140 3150 750 1900 0 ... 10 61 1000 - 2000 3000 - 6000 200 500 1500 3600 1000 2500 0 ... 16 62 1150 - 2300 3500 - 7000 280 700 2100 3960 1400 3500 0 ... 25 0 ... 40 100 200 63 1350 - 2700 4200 - 8400 360 900 2700 5500 1800 4500 64 1700 - 3400 5350 - 10700 440 1100 3300 7350 2200 5500 0 ... 60 65 2100 - 4200 6900 - 13800 520 1300 3900 9600 2600 6500 0 ... 100 66 3000 - 6000 10000-20000 600 1500 4500 13200 3000 7500 The value of the dead band is depending on the value of the set point. This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to the dead band spring totally released and the higher corresponds to the dead band spring fully tensed. For other set points the dead band value can be calculated by linear interpolation between the values at 10% and 90%. 1) www.baumer.com Data sheet A32.02 Page 2 / 4 Design and specifications subject to change without notice P. Max accidental 2015-04-21 Scale P. Max permanent RP2E Compact pressure switch Explosion proof Micro switches characteristics Switch code R L M N P U Fixed dead band Type Adjustable Dead band Standard Gold contact Tropicalized Ultra sensitive Double 6 Vdc 0.4 ... 10 A N/A 10 ... 50 mA 0.1 ... 8 A 0.4 ... 4 A 0.4 ... 10 A 12 Vdc 0.4 ... 10 A N/A 10 ... 50 mA 0.1 ... 8 A 0.4 ... 4 A 0.4 ... 10 A 24 Vdc 0.4 ... 5 A N/A 10 ... 50 mA 0.1 ... 8 A 0.4 ... 4 A 0.4 ... 6 A 30 Vdc 0.4 ... 5 A N/A 10 ... 50 mA 0.1 ... 8 A 0.4 ... 2 A 0.4 ... 6 A 48 Vdc 0.4 ... 5 A N/A 10 ... 50 mA 0.1 ... 8 A N/A 0.4 ... 6 A 110 Vdc 0.2 ... 0.5 A N/A 10 ... 50 mA N/A N/A 0.4 ... 0.5 A 220 Vdc 0.1 ... 0.25 A N/A 10 ... 50 mA N/A N/A 0.1 ... 0.25 A 115 Vac 0.4 ... 10 A 0.4 ... 10 A 10 ... 50 mA 0.1 ... 10 A N/A 0.4 ... 10 A 250 Vac 0.2 ... 10 A 0.2 ... 10 A N/A 0.1 ... 10 A N/A 0.2 ... 10 A 2000 V 2000 V 2000 V 2000 V 1000 V 2000 V Dielectric rigidity between contacts and ground Electrical connections 2 x SPDT 1 x SPDT NC COM NO Blue Red White NC Blue COM Red NO White Yellow / green NC Blue COM Red NO White Hazardous areas : zone 1, 2, 21, 22 -20°C ≤ Ta ≤ +70°C Dust IP65 Gases T° surface Class Ta = 60°C 80°C T6 Ta = 70°C 95°C T5 Important : Maximum power dissipation in the case must not exceed 5 W Yellow / green All necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's temperature to such that it reaches the self-ignition temperature of the gas in which it is used. Design and specifications subject to change without notice Dimensions (mm) 2 fixing holes for M6 screw ATEX certified Cable gland (not mounted) www.baumer.com 2015-04-21 1/4 NPT female Data sheet A32.02 Page 3 / 4 RP2E Compact pressure switch Explosion proof Ordering details RP2E RP2 Model Compact pressure switch RP2 Approvals ATEX Explosion proof Type of micro switches 1 SPDT standard change over switch 1 SPDT gold contact change over switch 1 SPDT tropicalized change over switch 1 SPDT hermetically ultra sensitive change over switch 1 SPDT change over switch with adjustable dead band 2 SPDT double change over switch . – xx / – E L M N P R U . Process connection G1/2 male (standard) 1/2 NPT male 1/4 NPT female 1/2 NPT female Pressure range (bar) Over pressure max. (bar) 0 ... 1 10 0 ... 1.6 10 0 ... 2.5 10 0 ... 4 10 0 ... 6 10 0 ... 10 10 0 ... 4 40 0 ... 6 40 0 ... 10 40 0 ... 16 40 0 ... 25 40 0 ... 40 40 0 ... 10 100 0 ... 16 100 0 ... 25 100 0 ... 40 100 0 ... 60 100 0 ... 100 100 Options to be added behind the / (see example below) 3 6 8 N 41 42 43 44 45 46 51 52 53 54 55 56 61 62 63 64 65 66 / Ordering example with options RP2 – E L . 3 53 / 0765 _ 0407 _ 9941 Compact pressure switch ATEX Explosion proof 1 SPDT standard change over switch Design and specifications subject to change without notice Process connection G1/2 male Pressure range 0 ... 10 bar over pressure max. 40 bar Option : Oxygen application Option : Mounting on 2" pipe 2015-04-21 Option : Stainless steel tag plate and wire www.baumer.com Data sheet A32.02 Page 4 / 4