RTNE3 - RTAE3
Industrial temperature switch, direct mounting
explosion proof
Main Features
„„
Excellent repeatability
„„
Dead band adjustment for regulation
„„
Fix dead band for control and alarm
„„
Explosion proof Hazardous areas 1, 2, 21, 22
Applications
„„Power generation safety equipment
Technical Data
-46 ... 0°C to 40 ... 120°C
Temperature
Process : Ambient : Storage : -46 ... +120°C
-30 ... +55°C
-40 ... +55°C
Repeatability
± 1% F.S. @ constant temperature cycle
CE conformity
Low Voltage Directive LVD 2006/95/EC
ATEX Directive 94/9/EC
IP 66 (EN 60529)
Protection rating
Process connection
Bulb
Scale
RTA :
Copper alloy
RTN :
Stainless steel 1.4404 (316L)
RTA :
Copper alloy
RTN :
Stainless steel 1.4404 (316L)
Internal. Accuracy on reading ± 5% FS
Housing
Type RA80, explosion proof, flameproof
Alumunium epoxy painted.
Captive stainless steel screws
Mounting
3 back lugs for wall mounting
Ground connection
Via internal terminal block
Electrical
connection
Terminal block with metallic cable gland for
Ø 7 to 12 mm standard
Electrical function
See ordering code details on page 5
Adjustment
2 external adjustment screws on top of the case
for set point and dead band
Type examination certificate
LCIE 03 ATEX 6231X (Type RA80)
EN 60079-0: 2012 (internal conformity analysis)
EN 60079-1: 2007
EN 60079-31: 2009
Marking
0081
II 2 G D
Ex d IIC T6 or T5 Gb
Ex t IIIC IIC T80°C or T95°C Db IP6X
T° ambient
-20°C to +60°C (T6 or T80°C) or
-20°C to +70°C (T5 or T95°C)
ATEX
Design and specifications subject to change without notice
Temperature range
Options
Code SETP
Stainless steel tag plate and wire
Code 9941
Lead seal of the adjustment screws
Code 8990
Nuclear cleanliness (RTN only)
Code 0838
2015-05-26
Customer specific set point adjustment
www.baumer.com
Data sheet B31.12
Page 1 / 5
RTNE3 - RTAE3
Industrial temperature switch, direct mounting
explosion proof
Principle
A vapour filled flexible sensing element actuates a microswitch by
means of a lever. The set point is adjusted by means of a compressible spring installed in opposition.
NC
NC
C
C
NC
C
NO
NO
NO
Set point and reset point must be between 10% and 90% of the
selected scale.
Standard factory adjustment
Setpoint at 50% of the scale on falling temperature
NC
C
NO
NC
NC
C
C
NO
NO
Customer specific factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising temperature
• Dead band value when using an adjustable dead band switch
Electrical connections
2 SPDT
1 SPDT
NC
COM
NO
Blue
Red
White
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
NO
White
Yellow / green
Hazardous areas : 1, 2, 21, 22
-20°C ≤ Ta ≤ +70°C
Dust IP6x
Gases
T° surface
Class
Ta = 60°C
80°C
T6
Ta = 70°C
95°C
T5
Important : Maximum power dissipation in the case
must not exceed 5 W
2015-05-26
All necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's
temperature to such that it reaches the self-ignition temperature of the gas in which it is used.
Design and specifications subject to change without notice
Yellow / green
www.baumer.com
Data sheet B31.12
Page 2 / 5
RTNE3 - RTAE3
Industrial temperature switch, direct mounting
explosion proof
Micro switches characteristics
Switch code
N (T)
A (B)
M (K)
C (W)
E (F)
D (V)
Type
Tropicalized
Standard
Gold contact
Hermetic
Ultra sensitive
Ultra sensitive
Hermetic
6 Vdc
0.1 ... 8 A
0.4 ... 10 A
10 ... 50 mA
5 mA ... 4 A
0.4 ... 1 A
0.4 ... 4 A
12 Vdc
0.1 ... 8 A
0.4 ... 10 A
10 ... 50 mA
5 mA ... 4 A
0.4 ... 1 A
0.4 ... 4 A
24 Vdc
0.1 ... 8 A
0.4 ... 6 A
10 ... 50 mA
5 mA ... 4 A
0.4 ... 1 A
0.4 ... 4 A
30 Vdc
0.1 ... 8 A
0.4 ... 6 A
10 ... 10 mA
5 mA ... 3 A
0.4 ... 1 A
0.4 ... 2 A
48 Vdc
0.1 ... 8 A
0.4 ... 6 A
10 ... 50 mA
5 mA ... 3 A
N/A
N/A
110 Vdc
N/A
0.1 ... 0.5 A
10 ... 50 mA
5 mA ... 1 A
N/A
N/A
220 Vdc
N/A
0.1 ... 0.25 A
10 ... 50 mA
5 mA ... 0.5 A
N/A
N/A
115 Vac
0.1 ... 10 A
0.4 ... 10 A
10 ... 50 mA
50 mA ... 3 A
0.4 ... 10 A
N/A
250 Vac
0.1 ... 5 A
0.2 ... 10 A
10 ... 10 mA
50 mA ... 2.5 A
0.2 ... 10 A
N/A
2000 V
2000 V
2000 V
1500 V
2000 V
1000 V
Dielectric rigidity between contacts and ground
Adjustable ranges
Micro-switch dead band 1)
TMax
Scale
accidential
Adjustable dead band
Code
N (T*)
10%
°C
A (B*)
M (K*)
90%
10%
E (F*)
90%
D (V*)
10%
90%
10%
90%
2.25
1.2
7.5
3.7
°C
0
40
300
6 - 13
3 - 13
-20 ... 20
60
301
4.5 - 12
0
... 45
60
302
6 - 13
40 ... 120
145
303
20 ... 80
100
315
-46 ... Fixed dead band
C (W*)
12 - 18
6 - 18
2.2 - 12
9 - 15
6 - 15
1.5
0.75
6
3
3 - 13
10 - 18
6 - 18
2.25
1.05
7.5
3.7
7.5 - 24
4.5 - 24
15 - 30
9 - 30
3
1.8
9
6
7.5 - 18
4.5 - 18
13 - 22
7.5 - 22
3
1.5
9
4.5
(*) For version with 2 microswitches lower values of the dead band must be multiplied x 1.5
The value of the dead band is depending on the value of the set point.
This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to
the dead band spring totally released and the higher corresponds to the dead band spring fully tensed. For other set points the dead band value can be calculated
by linear interpolation between the values at 10% and 90%.
2015-05-26
Design and specifications subject to change without notice
1)
www.baumer.com
Data sheet B31.12
Page 3 / 5
RTNE3 - RTAE3
Industrial temperature switch, direct mounting
explosion proof
Dimensions (mm)
Set point adjustment
Differential adjustment
Ø 194
56
(3x) Ø 9 on Ø 222
86
20
12
0°
Weight of the
housing : 4.4 kg
120°
116
RA
139
EE
x d II C T
0°
6
12
Cable gland
not mounted
121
Set point adjustment
Differential adjustment
Ø 194
Thermowell
116
RA
139
Thermowell for RTxx3
Stainless steel
Ordering code : 10271317
EE
x d II C T
6
Hex 29
22
20
3/4 NPT
3/4 BSP.TR
70
103
P= 135
G 3/8
Ø 18X16
2015-05-26
Design and specifications subject to change without notice
Ø 14
www.baumer.com
Data sheet B31.12
Page 4 / 5
RTNE3 - RTAE3
Industrial temperature switch, direct mounting
explosion proof
Ordering details RTNE3 - RTAE3
RT
Model
Industrial temperature switch
RT
Type of the bulb
Copper alloy bulb
Stainless steel bulb
Approvals
ATEX explosion proof
Type of micro switches
1 SPDT standard changeover switch
2 SPDT standard changeover switch
1 SPDT hermetically changeover switch
2 SPDT hermetically changeover switch
1 SPDT ultra sensitive changeover switch
2 SPDT ultra sensitive changeover switch
1 SPDT hermetically, ultra sensitive changeover switch
2 SPDT hermetically, ultra sensitive changeover switch
1 SPDT gold contact changeover switch
2 SPDT gold contact changeover switch
1 SPDT tropicalized changeover switch
2 SPDT tropicalized changeover switch
E
–
.
3xx
.
E
0
0
E
J
/
–
A
N
E
Deadband
Adjustable
Adjustable
Adjustable
Adjustable
Fix
Fix
Fix
Fix
Adjustable
Adjustable
Adjustable
Adjustable
A
B
C
W
E
F
D
V
M
K
N
T
Temperature range (°C)
-46... 0
-20 ... 20
0 ... 45
40 ... 120
20 ... 80
.
300
301
302
303
315
.
Type of design
Direct mounting (TRD)
Capillary length
Without capillary
Stem length P
P=135 mm
Bulb diameter
Ø 14 mm
Process connection
G3/8
Options to be added behind the / (see example below)
E
0
0
E
J
/
Ordering example with options
RT
–
A
E
A
.
300
.
E
0
0
E
J
/
SETP
_
9941
Industrial temperature switch
Design and specifications subject to change without notice
Copper alloy bulb
With ATEX explosion proof
1 SPDT standard changeover switch
Temperature range -46 ... 0 °C
TRD direct mounting
Without capillary
Immersion length P=135 mm
Bulb diameter Ø 14mm
Process connection G3/8
Option : Customer specific set point adjustment
2015-05-26
Option : Stainless steel tag plate and wire
www.baumer.com
Data sheet B31.12
Page 5 / 5