Datasheet - MtronPTI

OBSOLETE
K1523BA Series
5V Voltage Controlled Crystal Oscillators
Applications: Phase-Locked Loops (PLL’s); Clock
Recovery; Reference Signal Tracking; Synthesizers;
Frequency Modulation/Demodulation
2.0 to 35.0 MHz Frequency Range
0.5V to 4.5V Control Voltage
±25ppm Stability
Variety of Deviation Sensitivity Options
-40°C to 85°C Operating Temperature
8(
*+7
*66
$
5
"%
8(
*+7
*66
4
5
$)
%&' 2
!"##$()))*+,/2*.31
% /0*1'
.
8(
+7
6*
*6
"
45#
90:*"
Not Recommended for New Designs. Refer to
K1570A & K1570AQH Series as an Alternative.
E L E C T R I C A L S P E C I F I C AT I O N S
Model
K1523BA
Frequency Range (MHz)
Input Current (mA)
Frequency Control Function
2 to 16
16 to 25
< 17
< 19
25 to 33
33.1 to 35
< 26
(For Custom Deviation Range, Vc Range, etc. - Consult Factory)
Deviation (ppm)
Minimum
±100
±100
Maximum
±150
±190
Linearity (%)
Modulation Bandwidth (±3dB)
<5
< 10
> 2KHz
> 20KHz
Nominal Control Voltage (V)
2.5
Control Voltage Range (V)
0.5 to 4.5
Transfer Function
Positive
Input Impedance
> 50KΩ @ 10KHz
Frequency Stability (ppm)
Overall
Inclusive of Calibration, Temperature, Voltage, Load and Aging
0oC to +70oC
-40oC to +85oC
±25
±40
±50
±55
Temperature Range (oC)
-40oC to +85oC
-40oC to +125oC
Operating
Storage
Supply Voltage (V)
+5.0V ±5%
Symmetry (%) CMOS/TTL
45/55
40/60
Start Up Time (ms)
<10
Typical SSB Phase Noise (dBC/Hz)
10Hz
Offset from Carrier
100Hz
-65
-95
1KHz
-120
10KHz
-140
100KHz
-150
PA R T N U M B E R I N G G U I D E
K1523BA X - Specify Frequency
“Blank” = 0°C to 70°C Operating Temp.
“M” = -40°C to +85°C Operating Temp.
2553 N. Edgington Street, Franklin Park, IL 60131
Phone: 847.451.1000
800-888-1499 or www.champtech.com
1
Fax: 847.451.7585
OBSOLETE
K1523BA Series
5V Voltage Controlled Crystal Oscillators
PIN
FUNCTION
1
Voltage Control
7
Gnd/ & Case Gnd
8
Output
+ VCC
14
SHIPPING TUBE CROSS SECTION
TEST CIRCUIT DIAGRAM
OUTPUT WAVEFORM
MECHANICAL AND ENVIRONMENTAL SPECIFICATIONS
TEST METHODS
REFERENCE PROCEDURES
DESCRIPTION
Temperature Cycle
MIL-STD-833, Mtd 1010, Cond. B
-55°C to +125°C; Air-to-Air; 100 cycles; 10
min. dwell
Mechanical Shock
MIL-STD-883, Mtd 2002, Cond. B
1500 g’s
Vibration
MIL-STD 883, Mtd 2007, Cond. B
20-2000 Hz; 0.06 inch; 15g’s; 3 planes
Humidity Steady State
MIL-STD-202, Mtd 103
40°C; 90%-95% R.H.; 56 days
Thermal Shock
MIL-STD-883, Mtd 1011.7 Cond. B
100°C to 0°C; Water-to-Water; 15 cycles
Electrostatic Discharge
MIL-STD-883, Mtd 3015 Class II
2 KV to 4 KV Threshold
Solderability
Hermeticity
MIL-STD-883, Mtd 2022.2
MIL-STD-883, Mtd 1014.8, Cond. A1
Solder dip; Meniscograph Criteria
Mass spectro. 2 x 10-8 atmos. CC/sec He
Resistance to Soldering
Lead Integrity
MIL-STD-202, Mtd 210D, Cond. C
260°C; 10 seconds: 1 inch/sec.
MIL-STD-883, Mtd 2004.5, Cond. A, B1 Lead tension & bend stress
Marking Permanence
Life Test
MIL-STD-883, Mtd 2015.8
MIL-STD-883, Mtd 1005.6
Resistance to solvents
125°C, powered, 1000 hours minimum
2553 N. Edgington Street, Franklin Park, IL 60131
Phone: 847.451.1000
800-888-1499 or www.champtech.com
2