SS26V-R300038

AC Line Filters
SS Coils, SS26V Type
Overview
Applications
The KEMET SS Coils, SS26V Type AC line filters are offered in a
wide variety of sizes and specifications.
• Consumer Electronics
• Common mode choke
Benefits
• Wide variety of sizes and specifications
• High inductance in a compact design
• Pin pitch is identical to SS28V Type and SS24V Type,
making design and replacement easier
• Inductances up to 117 mH
• Rated Currents up to 3 A
• DC Resistances as low as 0.10 Ω
Part Number System
SS
26
V-
R
05
1170
Series
Core Size (mm)
Core Orientation
Core Type
Rated Current (A)
Minimum Inductance (mH)
SS
26 = 26.0
V- = Vertical
Blank = Standard
R = High permeability
0x = 0.x A (e.g., 05 = 0.5 A)
xx = x.x A (e.g., 25 = 2.5 A)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
xxx0 = xxx mH (e.g., 1170 = 117 mH)
0xxx = xx mH (e.g., 0162 = 16.2 mH)
00xx = x.x mH (e.g., 0038 = 3.8 mH)
One world. One KEMET
LF0030_SS26V • 6/16/2014
1
AC Line Filters – SS Coils, SS26V Type
Dimensions – Millimeters
SS26V
Marking
13
(1.5)
10
(4)
30.5 ±1.0
SS28V
ø0.8
13.0 ±0.5
(1.5)
SS26V
SS26V
10.0 ±0.5
26.0 ±1.0
20.5 ±1.0
Size Comparison with SS28V Type
(1.5)
(1.5)
(0.25)
SS28V
(0.25)
(4)
SS28V
SS26V
SS26V
SS26V
Environmental Compliance
All KEMET AC Line Filters are RoHS Compliant.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0030_SS26V • 6/16/2014
2
(0.25
AC Line Filters – SS Coils, SS26V Type
Table 1 – Ratings & Part Number Reference
Part Number
Rated Current
AC (A)
Inductance
(mH)
Minimum
DC Resistance/
Line (Ω)
Maximum
Temperature
Rise (K)
Maximum
Marking
Weight (g)
Approximate
SS26V-050880
SS26V-060640
SS26V-070510
SS26V-080350
SS26V-100250
SS26V-120169
SS26V-150121
SS26V-180092
SS26V-200076
SS26V-250046
SS26V-300028
SS26V-R051170
SS26V-R060860
SS26V-R070680
SS26V-R080470
SS26V-R100330
SS26V-R120220
SS26V-R150162
SS26V-R180123
SS26V-R200102
SS26V-R250061
SS26V-R300038
0.5
0.6
0.7
0.8
1.0
1.2
1.5
1.8
2.0
2.5
3.0
0.5
0.6
0.7
0.8
1.0
1.2
1.5
1.8
2.0
2.5
3.0
88
64
51
35
25
16.9
12.1
9.2
7.6
4.6
2.8
117
86
68
47
33
22
16.2
12.3
10.2
6.1
3.8
2.4
1.8
1.4
1.0
0.7
0.55
0.40
0.30
0.25
0.15
0.10
2.4
1.8
1.4
1.0
0.7
0.55
0.40
0.30
0.25
0.15
0.10
45
45
50
45
45
50
50
50
50
50
50
45
45
50
45
45
50
50
50
50
50
50
05 Lot No.
06 Lot No.
07 Lot No.
08 Lot No.
10 Lot No.
12 Lot No.
15 Lot No.
18 Lot No.
20 Lot No.
25 Lot No.
30 Lot No.
R05 Lot No.
R06 Lot No.
R07 Lot No.
R08 Lot No.
R10 Lot No.
R12 Lot No.
R15 Lot No.
R18 Lot No.
R20 Lot No.
R25 Lot No.
R30 Lot No.
25.3
25.4
25.2
25.0
25.8
22.6
23.5
24.3
25.9
24.3
23.0
25.3
25.4
25.2
25.0
25.8
22.6
23.5
24.3
25.9
24.3
23.0
Specifications
Item
SS26V
Rated Voltage
250 VAC
Withstanding Voltage
2400 VAC (2 seconds, between lines)
Insulation Resistance
> 100 MΩ @ 500 VDC (between lines)
Thermal Class
E (120°C)
Operating Temperature Range
-25ºC to T (T = 120 - temperature rise)
Inductance Measurement Condition
1 kHz, 1 V, KC530
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0030_SS26V • 6/16/2014
3
Common mode
AC Line Filters – SS Coils, SS26V Type
Frequency Characteristics
Impedance vs. Frequency
1M 1
1M 1
6
3
6
3
10K 1
100K 1
Impedance ()
100K 1
Impedance ()
6
3
050880
060640
070510
080350
100250
6
3
1K 1
120169
6
3
100 1
6
3
10 1
6
3
1
1K
3
6
1
3
10K
6
1
3
6
100K
1
3
6
1
200076
6
3
250046
1K 1
6
3
300028
100 1
6
3
10M
1M
Frequency (Hz)
6
3
3
1
1K
30M
3
6
1
3
10K
6
1
3
6
100K
1
3
6
1
10M
1M
Frequency (Hz)
3
30M
6
3
R051170
R060860
R070680
6
3
10K 1
100K 1
Impedance ()
100K 1
Impedance ()
10K 1
1M 1
6
3
R080470
6
3
R100330
R120220
1K 1
6
3
100 1
6
3
10 1
6
3
180092
10 1
1M 1
1
1K
150121
6
3
R150162
6
3
R180123
10K 1
R200102
6
3
R250061
1K 1
R300038
6
3
100 1
6
3
10 1
3
6
1
10K
3
6
1
100K
3
6
1
1M
Frequency (Hz)
3
6
1
10M
3
30M
6
3
1
1K
3
6
1
3
10K
6
1
100K
3
6
1
1M
Frequency (Hz)
3
6
1
10M
3
30M
Notes on Use
Shelf Life
• Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use.
Storage Condition
• Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external
electrode.
• Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the
solderability of external electrode.
• Avoid storage near strong magnetic field, as such condition may magnetize the product.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0030_SS26V • 6/16/2014
4
AC Line Filters – SS Coils, SS26V Type
KEMET Corporation
World Headquarters
Europe
Asia
Southern Europe
Paris, France
Tel: 33-1-4646-1006
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
Sasso Marconi, Italy
Tel: 39-051-939111
Shenzhen, China
Tel: 86-755-2518-1306
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Central Europe
Landsberg, Germany
Tel: 49-8191-3350800
Corporate Offices
Fort Lauderdale, FL
Tel: 954-766-2800
Kamen, Germany
Tel: 49-2307-438110
North America
Northern Europe
Bishop’s Stortford, United Kingdom
Tel: 44-1279-460122
2835 KEMET Way
Simpsonville, SC 29681
Southeast
Lake Mary, FL
Tel: 407-855-8886
Espoo, Finland
Tel: 358-9-5406-5000
Northeast
Wilmington, MA
Tel: 978-658-1663
Beijing, China
Tel: 86-10-5829-1711
Shanghai, China
Tel: 86-21-6447-0707
Taipei, Taiwan
Tel: 886-2-27528585
Southeast Asia
Singapore
Tel: 65-6586-1900
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Central
Novi, MI
Tel: 248-306-9353
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0030_SS26V • 6/16/2014
5
AC Line Filters – SS Coils, SS26V Type
Disclaimer
This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market
and product offerings for both companies and their respective customers. For more information, please visit http://www.kemet.com/nectokin.
Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare
notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not
be required.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0030_SS26V • 6/16/2014
6