AC Line Filters SS Coils, SS26V Type Overview Applications The KEMET SS Coils, SS26V Type AC line filters are offered in a wide variety of sizes and specifications. • Consumer Electronics • Common mode choke Benefits • Wide variety of sizes and specifications • High inductance in a compact design • Pin pitch is identical to SS28V Type and SS24V Type, making design and replacement easier • Inductances up to 117 mH • Rated Currents up to 3 A • DC Resistances as low as 0.10 Ω Part Number System SS 26 V- R 05 1170 Series Core Size (mm) Core Orientation Core Type Rated Current (A) Minimum Inductance (mH) SS 26 = 26.0 V- = Vertical Blank = Standard R = High permeability 0x = 0.x A (e.g., 05 = 0.5 A) xx = x.x A (e.g., 25 = 2.5 A) © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com xxx0 = xxx mH (e.g., 1170 = 117 mH) 0xxx = xx mH (e.g., 0162 = 16.2 mH) 00xx = x.x mH (e.g., 0038 = 3.8 mH) One world. One KEMET LF0030_SS26V • 6/16/2014 1 AC Line Filters – SS Coils, SS26V Type Dimensions – Millimeters SS26V Marking 13 (1.5) 10 (4) 30.5 ±1.0 SS28V ø0.8 13.0 ±0.5 (1.5) SS26V SS26V 10.0 ±0.5 26.0 ±1.0 20.5 ±1.0 Size Comparison with SS28V Type (1.5) (1.5) (0.25) SS28V (0.25) (4) SS28V SS26V SS26V SS26V Environmental Compliance All KEMET AC Line Filters are RoHS Compliant. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0030_SS26V • 6/16/2014 2 (0.25 AC Line Filters – SS Coils, SS26V Type Table 1 – Ratings & Part Number Reference Part Number Rated Current AC (A) Inductance (mH) Minimum DC Resistance/ Line (Ω) Maximum Temperature Rise (K) Maximum Marking Weight (g) Approximate SS26V-050880 SS26V-060640 SS26V-070510 SS26V-080350 SS26V-100250 SS26V-120169 SS26V-150121 SS26V-180092 SS26V-200076 SS26V-250046 SS26V-300028 SS26V-R051170 SS26V-R060860 SS26V-R070680 SS26V-R080470 SS26V-R100330 SS26V-R120220 SS26V-R150162 SS26V-R180123 SS26V-R200102 SS26V-R250061 SS26V-R300038 0.5 0.6 0.7 0.8 1.0 1.2 1.5 1.8 2.0 2.5 3.0 0.5 0.6 0.7 0.8 1.0 1.2 1.5 1.8 2.0 2.5 3.0 88 64 51 35 25 16.9 12.1 9.2 7.6 4.6 2.8 117 86 68 47 33 22 16.2 12.3 10.2 6.1 3.8 2.4 1.8 1.4 1.0 0.7 0.55 0.40 0.30 0.25 0.15 0.10 2.4 1.8 1.4 1.0 0.7 0.55 0.40 0.30 0.25 0.15 0.10 45 45 50 45 45 50 50 50 50 50 50 45 45 50 45 45 50 50 50 50 50 50 05 Lot No. 06 Lot No. 07 Lot No. 08 Lot No. 10 Lot No. 12 Lot No. 15 Lot No. 18 Lot No. 20 Lot No. 25 Lot No. 30 Lot No. R05 Lot No. R06 Lot No. R07 Lot No. R08 Lot No. R10 Lot No. R12 Lot No. R15 Lot No. R18 Lot No. R20 Lot No. R25 Lot No. R30 Lot No. 25.3 25.4 25.2 25.0 25.8 22.6 23.5 24.3 25.9 24.3 23.0 25.3 25.4 25.2 25.0 25.8 22.6 23.5 24.3 25.9 24.3 23.0 Specifications Item SS26V Rated Voltage 250 VAC Withstanding Voltage 2400 VAC (2 seconds, between lines) Insulation Resistance > 100 MΩ @ 500 VDC (between lines) Thermal Class E (120°C) Operating Temperature Range -25ºC to T (T = 120 - temperature rise) Inductance Measurement Condition 1 kHz, 1 V, KC530 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0030_SS26V • 6/16/2014 3 Common mode AC Line Filters – SS Coils, SS26V Type Frequency Characteristics Impedance vs. Frequency 1M 1 1M 1 6 3 6 3 10K 1 100K 1 Impedance () 100K 1 Impedance () 6 3 050880 060640 070510 080350 100250 6 3 1K 1 120169 6 3 100 1 6 3 10 1 6 3 1 1K 3 6 1 3 10K 6 1 3 6 100K 1 3 6 1 200076 6 3 250046 1K 1 6 3 300028 100 1 6 3 10M 1M Frequency (Hz) 6 3 3 1 1K 30M 3 6 1 3 10K 6 1 3 6 100K 1 3 6 1 10M 1M Frequency (Hz) 3 30M 6 3 R051170 R060860 R070680 6 3 10K 1 100K 1 Impedance () 100K 1 Impedance () 10K 1 1M 1 6 3 R080470 6 3 R100330 R120220 1K 1 6 3 100 1 6 3 10 1 6 3 180092 10 1 1M 1 1 1K 150121 6 3 R150162 6 3 R180123 10K 1 R200102 6 3 R250061 1K 1 R300038 6 3 100 1 6 3 10 1 3 6 1 10K 3 6 1 100K 3 6 1 1M Frequency (Hz) 3 6 1 10M 3 30M 6 3 1 1K 3 6 1 3 10K 6 1 100K 3 6 1 1M Frequency (Hz) 3 6 1 10M 3 30M Notes on Use Shelf Life • Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use. Storage Condition • Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external electrode. • Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the solderability of external electrode. • Avoid storage near strong magnetic field, as such condition may magnetize the product. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0030_SS26V • 6/16/2014 4 AC Line Filters – SS Coils, SS26V Type KEMET Corporation World Headquarters Europe Asia Southern Europe Paris, France Tel: 33-1-4646-1006 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Sasso Marconi, Italy Tel: 39-051-939111 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg, Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Bishop’s Stortford, United Kingdom Tel: 44-1279-460122 2835 KEMET Way Simpsonville, SC 29681 Southeast Lake Mary, FL Tel: 407-855-8886 Espoo, Finland Tel: 358-9-5406-5000 Northeast Wilmington, MA Tel: 978-658-1663 Beijing, China Tel: 86-10-5829-1711 Shanghai, China Tel: 86-21-6447-0707 Taipei, Taiwan Tel: 886-2-27528585 Southeast Asia Singapore Tel: 65-6586-1900 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 Central Novi, MI Tel: 248-306-9353 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0030_SS26V • 6/16/2014 5 AC Line Filters – SS Coils, SS26V Type Disclaimer This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market and product offerings for both companies and their respective customers. For more information, please visit http://www.kemet.com/nectokin. Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0030_SS26V • 6/16/2014 6