AC Line Filters SC Coils, SC-JV Terminal Base Type Overview Applications The KEMET SC Coils, SC-JV Terminal Base Type AC line filters are offered in a wide variety of sizes and specifications. • Consumer Electronics • Common mode choke Benefits – Terminal Base Type • • • • e Wide variety of sizes and specifications Inductances up to 44 mH Rated Currents up to 5 A DC Resistances as low as 100 mΩ nt] DC resistance Inductance (m/line) (mH) max. min. 44+50%,–30% 300 Part Number System150 29+50%,–30% 15+50%,–30% 100 SC- Temperature rise(K) max. 45 55 55 02- Wire size (mmø) Recognized by: 0.6 0.8 0.9 VDE VDE VDE 300 Withstanding voltage: 2400V (2 sec between lines) Series lines, from line to tube) Rated Current (A) Minimum Inductance (mH) more than 50M (between • Thermal class: A (105˚C) –25 to T (T=105–temperature rise) SC0x- = x A (e.g., 02- = 2 A) 100 = 15 mH +50%, -30% 200 = 29 mH +50%, -30% n:16kHz, 0.2mA, KC547 Weight approx. (g) 45 45 45 JV Terminal Base Type JV 300 = 44 mH +50%, -30% (16) 25 max. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com (16) (18) [mm] One world. One KEMET LF0008_SC-JV • 6/16/2014 1 AC Line Filters – SC Coils, SC-JV Terminal Base Type Dimensions – Millimeters (16) Label 25 Maximum 5.0 ±2.0 40 Maximum 35 Maximum (18) (18) (16) Environmental Compliance All KEMET AC Line Filters are RoHS Compliant. Table 1 – Ratings & Part Number Reference Part Number Rated Current AC (A) Inductance (mH) Minimum SC-02-300JV SC-04-200JV SC-05-100JV 2 4 5 44 +50%, -30% 29 +50%, -30% 15 +50%, -30% DC Resistance/ Temperature Line (mΩ) Rise (K) Maximum Maximum 300 150 100 Wire Diameter (mm) 45 55 55 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com 0.6 0.8 0.9 Recognized Weight (g) By Approximate VDE VDE VDE 45 45 45 LF0008_SC-JV • 6/16/2014 2 (18) (18) (16) [mm] AC Line Filters – SC Coils, SC-JV Terminal Base Type Specifications Item SC-JV Rated Voltage 250 VAC/VDC Withstanding Voltage 2400 VAC (2 seconds, between lines) Insulation Resistance > 50 MΩ @ 500 VDC (between lines, from line to tube) Thermal Class A (105°C) Operating Temperature Range -25ºC to T (T = 105 - temperature rise) Inductance Measurement Condition 16 kHz, 0.2 mA, KC547 Frequency Characteristics quency characteristic 1M 1 6 3 Impedance () 100K 1 02-300JV 6 3 10K 1 6 3 1K 1 04-200JV 6 3 100 1 6 3 05-100JV 10 1 6 3 1 1K 3 6 1 10K 3 6 1 100K 3 6 1 1M Frequency (Hz) 3 6 1 10M 3 30M Notes on Use AC Line Filters 17 Shelf Life • Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use. Storage Condition • Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external electrode. • Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the solderability of external electrode. • Avoid storage near strong magnetic field, as such condition may magnetize the product. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0008_SC-JV • 6/16/2014 3 AC Line Filters – SC Coils, SC-JV Terminal Base Type KEMET Corporation World Headquarters Europe Asia Southern Europe Paris, France Tel: 33-1-4646-1006 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Sasso Marconi, Italy Tel: 39-051-939111 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg,Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Bishop’s Stortford, United Kingdom Tel: 44-1279-460122 2835 KEMET Way Simpsonville, SC 29681 Southeast Lake Mary, FL Tel: 407-855-8886 Espoo, Finland Tel: 358-9-5406-5000 Northeast Wilmington, MA Tel: 978-658-1663 Beijing, China Tel: 86-10-5829-1711 Shanghai, China Tel: 86-21-6447-0707 Taipei, Taiwan Tel: 886-2-27528585 Southeast Asia Singapore Tel: 65-6586-1900 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 Central Novi, MI Tel: 248-306-9353 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0008_SC-JV • 6/16/2014 4 AC Line Filters – SC Coils, SC-JV Terminal Base Type Disclaimer ThisproducthasbeenmadeavailablethroughaPrivateLabelAgreementandaDevelopmentandCross-LicensingAgreementbetweenKEMETandNECTOKINtoexpandmarket andproductofferingsforbothcompaniesandtheirrespectivecustomers.Formoreinformation,pleasevisithttp://www.kemet.com/nectokin. Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand verifyingtheextenttowhichtheInformationcontainedinthispublicationisapplicabletoanorderatthetimetheorderisplaced. AllInformationgivenhereinisbelievedtobeaccurateandreliable,butitispresentedwithoutguarantee,warranty,orresponsibilityofanykind,expressedorimplied. StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly bycustomerswhohavetherequisiteexperienceandcapabilitytodeterminethecorrectproductsfortheirapplication.AnytechnicaladviceinferredfromthisInformationorotherwise providedbyKEMETwithreferencetotheuseofKEMET’sproductsisgivengratis,andKEMETassumesnoobligationorliabilityfortheadvicegivenorresultsobtained. AlthoughKEMETdesignsandmanufacturesitsproductstothemoststringentqualityandsafetystandards,giventhecurrentstateoftheart,isolatedcomponentfailuresmaystill occur.Accordingly,customerapplicationswhichrequireahighdegreeofreliabilityorsafetyshouldemploysuitabledesignsorothersafeguards(suchasinstallationofprotective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Althoughallproduct–relatedwarnings,cautionsandnotesmustbeobserved,thecustomershouldnotassumethatallsafetymeasuresareindictedorthatothermeasuresmaynot berequired. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0008_SC-JV • 6/16/2014 5