AC Line Filters SU Coils, SU 10VFC-R Type Overview Applications The KEMET SU Coils, SU 10VFC-R Type AC line filters are offered in a wide variety of sizes and specifications. • Consumer Electronics • Common mode choke Benefits • • • • • Wide variety of sizes and specifications Super low profile: 15.0 mm maximum Inductances up to 37 mH Rated Currents up to 2.0 A DC Resistances as low as 0.15 Ω Part Number System SU 10 VFC- R 03 370 Series Core Size (mm) Core Orientation Core Type Rated Current (A) Minimum Inductance (mH) SU 10 = 10.0 VFC- = Vertical Blank = Standard R = High permeability 0x = 0.x A (e.g., 03 = 0.3 A) xx = x.x A (e.g., 15 = 1.5 A) xx0 = xx mH (e.g., 370 = 37 mH) 0xx = x.x mH (e.g., 025 = 2.5 mH) © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com One world. One KEMET LF0018_SU10VFC-R • 6/16/2014 1 AC Line Filters – SU Coils, SU 10VFC-R Type Dimensions – Millimeters 18.0 Maximum Marking 15.5 Maximum 3.50 ±0.7 13 ±0.5 N1 10 ±0.5 N2 10 15.0 Maximum 13 ø0.70 Environmental Compliance All KEMET AC Line Filters are RoHS Compliant. Table 1 – Ratings & Part Number Reference Part Number Rated Current AC (A) Inductance (mH) Minimum DC Resistance/ Line (Ω) Maximum Temperature Rise (K) Maximum Marking Weight (g) Approximate SU10VFC-R03370 SU10VFC-R04250 SU10VFC-R05140 SU10VFC-R07088 SU10VFC-R10045 SU10VFC-R13025 SU10VFC-R15019 SU10VFC-R17016 SU10VFC-R20010 0.3 0.4 0.5 0.7 1.0 1.3 1.5 1.7 2.0 37 25 14 8.8 4.5 2.5 1.9 1.6 1.0 4.2 2.8 1.6 1.1 0.55 0.30 0.24 0.21 0.15 45 45 45 50 50 50 50 55 55 R03 Lot No. R04 Lot No. R05 Lot No. R07 Lot No. R10 Lot No. R13 Lot No. R15 Lot No. R17 Lot No. R20 Lot No. 6.5 6.5 6.4 6.3 6.4 6.6 6.5 6.2 6.2 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0018_SU10VFC-R • 6/16/2014 2 • Rated voltage: 250VAC • Withstanding voltage: AC 2400V (2 sec between lines) • Insulation resistance: at 500VDC, more than 100M (between lines) • Thermal class: E (120˚C) • Operating temperature range (˚C): –25 to T (T=200–temperature rise) • Indactance measurement condition: 1kHz, 1V, KC530 Shape and Dimensions Marking AC Line Filters – SU Coils, SU 10VFC-R Type 18.0 max. 15.5 max. 15.0 max. Specifications Item N2 ø0.70 13±0.5 3.50 ±0.7 Rated Voltage N1 Withstanding Voltage Insulation Resistance 10 13 SU 10VFC-R 250 VAC 10±0.5 2400 VAC (2 seconds, between lines) [mm] > 100 MΩ @ 500 VDC (between lines) Thermal Class Numbering System E (120°C) Operating Temperature Range SU 10VFC - R 03 370 Inductance Measurement Condition � � � � � -25ºC toTSeries (T = 120 - temperature rise) size ; shape (V : vertical) 1 kHz, 1V,Core KC530 Core Type (R : High permeability core) Rated current (03 stands for 0.3A) Inductance (370 stands for 37.0mH) FrequencyFrequency Characteristics characteristic 1M 1 1M 1 6 3 100K 1 100K 1 R04250 6 3 R05140 10K 1 6 3 Impedance () Impedance () 6 3 R03370 R07088 1K 1 R10045 6 3 100 1 6 3 6 3 R13025 R15019 6 3 1K 1 R17016 6 3 R20010 100 1 6 3 10 1 10 1 1 1K 6 3 10K 1 3 6 1 10K 3 6 1 100K 3 6 1 1M Frequency (Hz) 3 6 1 10M 3 30M 6 3 1 1K 3 6 1 10K 3 6 1 100K 3 6 1 1M Frequency (Hz) Notes on Use 3 6 1 10M 3 30M AC Line Filters 29 Shelf Life • Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use. Storage Condition • Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external electrode. • Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the solderability of external electrode. • Avoid storage near strong magnetic field, as such condition may magnetize the product. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0018_SU10VFC-R • 6/16/2014 3 AC Line Filters – SU Coils, SU 10VFC-R Type KEMET Corporation World Headquarters Europe Asia Southern Europe Paris, France Tel:33-1-4646-1006 Northeast Asia Hong Kong Tel:852-2305-1168 MailingAddress: P.O. Box 5928 Greenville, SC 29606 Sasso Marconi, Italy Tel:39-051-939111 Shenzhen, China Tel:86-755-2518-1306 www.kemet.com Tel:864-963-6300 Fax:864-963-6521 Central Europe Landsberg, Germany Tel:49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel:954-766-2800 Kamen, Germany Tel:49-2307-438110 North America Northern Europe Bishop’s Stortford, United Kingdom Tel:44-1279-460122 2835 KEMET Way Simpsonville, SC 29681 Southeast Lake Mary, FL Tel:407-855-8886 Espoo, Finland Tel:358-9-5406-5000 Northeast Wilmington, MA Tel:978-658-1663 Beijing, China Tel:86-10-5829-1711 Shanghai, China Tel:86-21-6447-0707 Taipei, Taiwan Tel:886-2-27528585 Southeast Asia Singapore Tel:65-6586-1900 Penang, Malaysia Tel:60-4-6430200 Bangalore, India Tel:91-806-53-76817 Central Novi, MI Tel:248-306-9353 West Milpitas, CA Tel:408-433-9950 Mexico Guadalajara, Jalisco Tel:52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0018_SU10VFC-R • 6/16/2014 4 AC Line Filters – SU Coils, SU 10VFC-R Type Disclaimer This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market andproductofferingsforbothcompaniesandtheirrespectivecustomers.Formoreinformation,pleasevisithttp://www.kemet.com/nectokin. Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0018_SU10VFC-R • 6/16/2014 5