SU Coils SU 10VFC-R Type

AC Line Filters
SU Coils, SU 10VFC-R Type
Overview
Applications
The KEMET SU Coils, SU 10VFC-R Type AC line filters are
offered in a wide variety of sizes and specifications.
• Consumer Electronics
• Common mode choke
Benefits
•
•
•
•
•
Wide variety of sizes and specifications
Super low profile: 15.0 mm maximum
Inductances up to 37 mH
Rated Currents up to 2.0 A
DC Resistances as low as 0.15 Ω
Part Number System
SU
10
VFC-
R
03
370
Series
Core Size (mm)
Core Orientation
Core Type
Rated Current (A)
Minimum Inductance (mH)
SU
10 = 10.0
VFC- = Vertical
Blank = Standard
R = High permeability
0x = 0.x A (e.g., 03 = 0.3 A)
xx = x.x A (e.g., 15 = 1.5 A)
xx0 = xx mH (e.g., 370 = 37 mH)
0xx = x.x mH (e.g., 025 = 2.5 mH)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
One world. One KEMET
LF0018_SU10VFC-R • 6/16/2014
1
AC Line Filters – SU Coils, SU 10VFC-R Type
Dimensions – Millimeters
18.0 Maximum
Marking
15.5 Maximum
3.50 ±0.7
13 ±0.5
N1
10 ±0.5
N2
10
15.0 Maximum
13
ø0.70
Environmental Compliance
All KEMET AC Line Filters are RoHS Compliant.
Table 1 – Ratings & Part Number Reference
Part Number
Rated Current
AC (A)
Inductance
(mH)
Minimum
DC Resistance/
Line (Ω)
Maximum
Temperature
Rise (K)
Maximum
Marking
Weight (g)
Approximate
SU10VFC-R03370
SU10VFC-R04250
SU10VFC-R05140
SU10VFC-R07088
SU10VFC-R10045
SU10VFC-R13025
SU10VFC-R15019
SU10VFC-R17016
SU10VFC-R20010
0.3
0.4
0.5
0.7
1.0
1.3
1.5
1.7
2.0
37
25
14
8.8
4.5
2.5
1.9
1.6
1.0
4.2
2.8
1.6
1.1
0.55
0.30
0.24
0.21
0.15
45
45
45
50
50
50
50
55
55
R03 Lot No.
R04 Lot No.
R05 Lot No.
R07 Lot No.
R10 Lot No.
R13 Lot No.
R15 Lot No.
R17 Lot No.
R20 Lot No.
6.5
6.5
6.4
6.3
6.4
6.6
6.5
6.2
6.2
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0018_SU10VFC-R • 6/16/2014
2
• Rated voltage: 250VAC • Withstanding voltage: AC 2400V (2 sec between lines)
• Insulation resistance: at 500VDC, more than 100M (between lines)
• Thermal class: E (120˚C)
• Operating temperature range (˚C): –25 to T (T=200–temperature rise) • Indactance measurement condition: 1kHz, 1V, KC530
Shape and Dimensions
Marking
AC Line Filters – SU Coils, SU 10VFC-R
Type
18.0 max.
15.5 max.
15.0 max.
Specifications
Item
N2
ø0.70
13±0.5
3.50 ±0.7
Rated Voltage
N1
Withstanding Voltage
Insulation Resistance
10
13
SU 10VFC-R
250 VAC
10±0.5
2400 VAC (2 seconds,
between lines)
[mm]
> 100 MΩ @ 500 VDC (between lines)
Thermal Class
Numbering System
E (120°C)
Operating Temperature Range
SU 10VFC - R 03 370
Inductance Measurement
Condition
�
�
� � �
-25ºC toTSeries
(T = 120 - temperature rise)
size ; shape (V : vertical)
1 kHz, 1V,Core
KC530
Core Type (R : High permeability core)
Rated current (03 stands for 0.3A)
Inductance (370 stands for 37.0mH)
FrequencyFrequency
Characteristics
characteristic
1M 1
1M 1
6
3
100K 1
100K 1
R04250
6
3
R05140
10K 1
6
3
Impedance ()
Impedance ()
6
3
R03370
R07088
1K 1
R10045
6
3
100 1
6
3
6
3
R13025
R15019
6
3
1K 1
R17016
6
3
R20010
100 1
6
3
10 1
10 1
1
1K
6
3
10K 1
3
6
1
10K
3
6
1
100K
3
6
1
1M
Frequency (Hz)
3
6
1
10M
3
30M
6
3
1
1K
3
6
1
10K
3
6
1
100K
3
6
1
1M
Frequency (Hz)
Notes on Use
3
6
1
10M
3
30M
AC Line Filters
29
Shelf Life
• Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use.
Storage Condition
• Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external
electrode.
• Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the
solderability of external electrode.
• Avoid storage near strong magnetic field, as such condition may magnetize the product.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0018_SU10VFC-R • 6/16/2014
3
AC Line Filters – SU Coils, SU 10VFC-R Type
KEMET Corporation
World Headquarters
Europe
Asia
Southern Europe
Paris, France
Tel:33-1-4646-1006
Northeast Asia
Hong Kong
Tel:852-2305-1168
MailingAddress:
P.O. Box 5928
Greenville, SC 29606
Sasso Marconi, Italy
Tel:39-051-939111
Shenzhen, China
Tel:86-755-2518-1306
www.kemet.com
Tel:864-963-6300
Fax:864-963-6521
Central Europe
Landsberg, Germany
Tel:49-8191-3350800
Corporate Offices
Fort Lauderdale, FL
Tel:954-766-2800
Kamen, Germany
Tel:49-2307-438110
North America
Northern Europe
Bishop’s Stortford, United Kingdom
Tel:44-1279-460122
2835 KEMET Way
Simpsonville, SC 29681
Southeast
Lake Mary, FL
Tel:407-855-8886
Espoo, Finland
Tel:358-9-5406-5000
Northeast
Wilmington, MA
Tel:978-658-1663
Beijing, China
Tel:86-10-5829-1711
Shanghai, China
Tel:86-21-6447-0707
Taipei, Taiwan
Tel:886-2-27528585
Southeast Asia
Singapore
Tel:65-6586-1900
Penang, Malaysia
Tel:60-4-6430200
Bangalore, India
Tel:91-806-53-76817
Central
Novi, MI
Tel:248-306-9353
West
Milpitas, CA
Tel:408-433-9950
Mexico
Guadalajara, Jalisco
Tel:52-33-3123-2141
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0018_SU10VFC-R • 6/16/2014
4
AC Line Filters – SU Coils, SU 10VFC-R Type
Disclaimer
This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market
andproductofferingsforbothcompaniesandtheirrespectivecustomers.Formoreinformation,pleasevisithttp://www.kemet.com/nectokin.
Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare
notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not
be required.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0018_SU10VFC-R • 6/16/2014
5