AC Line Filters SU Coils, SU 10VD High Frequency Type Overview Applications The KEMET SU Coils, SU 10VD High Frequency Type AC line filters are offered in a wide variety of sizes and specifications. • Consumer Electronics • Common mode choke Benefits – High Frequency Type • • • • ype Wide variety of sizes and specifications Inductances up to 80 µH Rated Currents up to 2 A DC Resistances as low as 0.10 Ω nt] Rated urrent (A) 1 1 1 1 2 Inductance (μH) min. 80 50System Part Number 20 10 SU 10 Series DC resistance (/line) max. 0.20 0.20 0.12 0.10 10 0.10 Core Size (mm) Temperature rise(K) max. 45 45 45 45 VD45 Core Orientation Marking 10 D10080 D10050 D10020 D10010 D20010 Rated Current (A) nding voltage: AC 2400V (2 sec between lines) SU 10 = 10.0 VD- = Vertical x0 = x.0 A (e.g., 10 = 1.0 A) more than 100M (between lines) • Thermal class: E (120˚C) –25 to T (T=120–temperature rise) • Inductance measurement condition:1kHz, 1V, KC530 Weight approx. (g) 5.6 5.5 5.5 5.7 020 5.4 Minimum Inductance (µH) 0xx = xx µH (e.g., 020 = 20 µH) max. 20 max. 10 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com min. ±0.5 13 One world. One KEMET LF0020_SU10VD • 6/16/2014 1 AC Line Filters – SU Coils, SU 10VD High Frequency Type Dimensions – Millimeters 16 Maximum 13 20 Maximum 18 Maximum 13 ±0.5 10 ±0.5 4.0 Minimum 10 ø0.7 Environmental Compliance All KEMET AC Line Filters are RoHS Compliant. Table 1 – Ratings & Part Number Reference Part Number Rated Current AC (A) Inductance (µH) Minimum DC Resistance/ Line (Ω) Maximum Temperature Rise (K) Maximum Marking Weight (g) Approximate SU10VD-10080 SU10VD-10050 SU10VD-10020 SU10VD-10010 SU10VD-20010 1.0 1.0 1.0 1.0 2.0 80 50 20 10 10 0.20 0.20 0.12 0.10 0.10 45 45 45 45 45 D10080 D10050 D10020 D10010 D20010 5.6 5.5 5.5 5.7 5.4 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0020_SU10VD • 6/16/2014 2 13±0.5 10 4.0 min. ø0.7 10±0.5 [mm] AC Line Filters – SU Coils, SU 10VD High Frequency Type umbering System Specifications Series Core size; shape (V: vertical) Ni-Zn ferrite core SU 10VD VAC current (10 stands for 1.0A) 250 Rated 2400 VAC (2 seconds, between lines) Inductance (010 stands for 10μH) U 10V D - 10 010 � � Item � � Rated Voltage Withstanding Voltage Insulation Resistance > 100 MΩ @ 500 VDC (between lines) Thermal Class E (120°C) Operating Temperature Range -25ºC to T (T = 120 - temperature rise) Inductance Measurement Condition 1 kHz, 1 V, KC530 Frequency characteristic Frequency Characteristics 1M 1 6 3 Impedance () 100K 1 6 3 10K 1 6 3 10020 1K 1 6 3 10050 100 1 20010 10080 6 3 10 1 6 3 1 1K 10010 3 6 1 10K 3 6 1 100K 3 6 1 1M Frequency (Hz) 3 6 1 10M 3 30M Notes on Use AC Line Filters Shelf Life • Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use. 31 Storage Condition • Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external electrode. • Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the solderability of external electrode. • Avoid storage near strong magnetic field, as such condition may magnetize the product. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0020_SU10VD • 6/16/2014 3 AC Line Filters – SU Coils, SU 10VD High Frequency Type KEMET Corporation World Headquarters Europe Asia Southern Europe Paris, France Tel: 33-1-4646-1006 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Sasso Marconi, Italy Tel: 39-051-939111 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg,Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Bishop’s Stortford, United Kingdom Tel: 44-1279-460122 2835 KEMET Way Simpsonville, SC 29681 Southeast Lake Mary, FL Tel: 407-855-8886 Espoo, Finland Tel: 358-9-5406-5000 Northeast Wilmington, MA Tel: 978-658-1663 Beijing, China Tel: 86-10-5829-1711 Shanghai, China Tel: 86-21-6447-0707 Taipei, Taiwan Tel: 886-2-27528585 Southeast Asia Singapore Tel: 65-6586-1900 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 Central Novi, MI Tel: 248-306-9353 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0020_SU10VD • 6/16/2014 4 AC Line Filters – SU Coils, SU 10VD High Frequency Type Disclaimer ThisproducthasbeenmadeavailablethroughaPrivateLabelAgreementandaDevelopmentandCross-LicensingAgreementbetweenKEMETandNECTOKINtoexpandmarket andproductofferingsforbothcompaniesandtheirrespectivecustomers.Formoreinformation,pleasevisithttp://www.kemet.com/nectokin. Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand verifyingtheextenttowhichtheInformationcontainedinthispublicationisapplicabletoanorderatthetimetheorderisplaced. AllInformationgivenhereinisbelievedtobeaccurateandreliable,butitispresentedwithoutguarantee,warranty,orresponsibilityofanykind,expressedorimplied. StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly bycustomerswhohavetherequisiteexperienceandcapabilitytodeterminethecorrectproductsfortheirapplication.AnytechnicaladviceinferredfromthisInformationorotherwise providedbyKEMETwithreferencetotheuseofKEMET’sproductsisgivengratis,andKEMETassumesnoobligationorliabilityfortheadvicegivenorresultsobtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur.Accordingly,customerapplicationswhichrequireahighdegreeofreliabilityorsafetyshouldemploysuitabledesignsorothersafeguards(suchasinstallationofprotective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Althoughallproduct–relatedwarnings,cautionsandnotesmustbeobserved,thecustomershouldnotassumethatallsafetymeasuresareindictedorthatothermeasuresmaynot berequired. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0020_SU10VD • 6/16/2014 5