SCR-050-0R9A070J

AC Line Filters
SCR Coils, High Impedance Type
Overview
Applications
The KEMET SCR Coils, High Impedance Type AC line filters
feature a newly developed, high permeability core.
•
•
•
•
Audio-visual Equipment
Consumer Electronics
Power Supply Devices
Common mode choke
Benefits
• High impedance achieved by using a newly developed core with
high permeability
• 30% reduction in volume while maintaining the same properties,
thus saving space and reducing part count
• Inductances up to 25 mH
• Rated Currents up to 5 A
• DC Resistances as low as 47 mΩ
Part Number System
SCR-
020-
0R55
A250
JH
Series
Rated Current (A)
Wire Diameter (mm)
Minimum Inductance (mH)
Orientation
SCR-
0x0 = x A (e.g., 020 = 2 A)
R = Decimal point
(e.g., 0R55 = 0.55 mm,
0R8 = 0.8 mm)
xx0 = xx mH
(e.g., 250 = 25 mH)
0x0 = x mH
(e.g., 070 = 7 mH)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
J = Vertical
JH = Horizontal
One world. One KEMET
LF0014_SCR • 6/16/2014
1
AC Line Filters – SCR Coils, High Impedance Type
Dimensions – Millimeters
27 Maximum
27 Maximum
□□□□
(14)
(14)
(14) (14)
(14)
N2
N2
(17)
N1
N1
(17)
(17)
(17)
N2
23 Maximum
(14)
(14)
(17)
N2
(16)
(18)
(17)
N1
(14)
(16)
N2
N2
N1
(16)
N1
(16)
(16)
(16)
(18)
(18)
(18)
(18)
23 Maximum
Adhesive
Points
Solder 2Plating
Sn-0.75Cu
Solder Plating
Adhesive
Sn-0.75Cu 2 Points
Adhesive
2 Points
Adhesive
2 Points
Solder Plating
Sn-0.75Cu
8)
□□□□
□□□□
Marking
27 Maximum
23 Maximum
(18)
N1
29 Maximum
29 Marking
Maximum
Marking
Solder Plating
Sn-0.75Cu
Solder Plating
Sn-0.75Cu
Solder Plating
Sn-0.75Cu
29 Maximum
Marking 3.5 ±0.5
23 Maximum
23 Maximum29 Maximum
3.5 ±0.5
Marking
SCR-JH
Solder Length
Solder Length
Adhesive
Marking
4 Points
(0.5) (0.5)
Solder Length
(0.5)
29Length
Maximum
3.5 ±0.53.5 ±0.5
29 Maximum
Solder
23 Maximum
Adhesive
4 Points
□□□□
27 Maximum
29 Maximum
23 Maximum
Adhesive 23 Maximum
29 Maximum
4 Points
Adhesive
4 Points Marking
Marking
SCR-J
(0.5)
ximum
m
N1
N
N1
N2
Environmental Compliance
All KEMET AC Line Filters are RoHS Compliant.
Table 1 – Ratings & Part Number Reference
Part Number
Rated Current
AC (A)
Inductance
(mH)
Minimum
DC Resistance/
Line (mΩ)
Maximum
Temperature
Rise (K)
Maximum
Wire Diameter
(mm)
Weight (g)
Approximate
SCR-020-0R55A250(1)
SCR-030-0R6A170(1)
SCR-040-0R8A100(1)
SCR-050-0R9A070(1)
2
3
4
5
25
15
10
7
200
145
65
47
55
75
62
70
0.55
0.60
0.80
0.90
22.8
22.0
26.2
27.0
(1) To complete KEMET part number, insert J for vertical terminal type or JH for horizontal terminal type.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0014_SCR • 6/16/2014
2
VDC
• Withstanding voltage: 2400VAC (2sec. between lines)
00VDC, more than 100MΩ (between lines)
• Thermal class: E (120℃)
nge (℃): -25 to T (T=120-temperature rise)
• Inductance measurement condition: 10kHz, 1mA
ons
AC Line Filters – SCR Coils, High Impedance Type
㻕㻖㻰㼄㼛㻑
Item
SCR
Rated Voltage
250 VAC/VDC
㻶㼒㼏㼇㼈㼕㻃㼓㼏㼄㼗㼌㼑㼊
㻶㼑㻐㻓㻑㻚㻘㻦㼘
Withstanding Voltage
㻶㼒㼏㼇㼈㼕㻃㼓㼏㼄㼗㼌㼑㼊
㻶㼑㻐㻓㻑㻚㻘㻦㼘
㻤㼇㼋㼈㼖㼌㼙㼈
㻕㼓㼒㼌㼑㼗㼖
2400 VAC (2 seconds, between
lines)
㻋㻔㻗㻌
> 100 MΩ @ 500 VDC (between lines)
㻋㻔㻛㻌
Thermal Class
E (120°C)
䠠䠄
-25ºC to T (T = 120 - temperature rise)
㻋㻔㻙㻌
䠠䠃
Operating Temperature Range
㻋㻔㻗㻌
Inductance Measurement Condition
10 kHz, 1 mA
㻱㻔
㻋㻔㻚㻌
㻋㻔㻛㻌
Insulation
Resistance
㻖㻑㻘㼳㻓㻑㻘
㻋㻔㻚㻌
㻖㻑㻘㼳㻓㻑㻘
㻕㻖㻰㼄㼛㻑
㻰㼄㼕㼎㼌㼑㼊
□□□□
㻶㼒㼏㼇㼈㼕㻃㼏㼈㼑㼊㼗㼋
㻋㻓㻑㻘㻌
㻕㻜㻰㼄㼛㻑
Specifications
㻋㻔㻙㻌
㻕㻜㻰㼄㼛㻑
SCR-JH
㻤㼇㼋㼈㼖㼌㼙㼈
㻗㼓㼒㼌㼑㼗㼖
㻰㼄㼕㼎㼌㼑㼊
㻕㻚㻰㼄㼛㻑
㻕㻜㻰㼄㼛㻑
J
㻱㻕
[mm]
Frequency Characteristics
teristic
1M 1
6
3
Impedance ()
100K 1
6
3
020-0R55A250J/JH
030-0R6A170J/JH
10K 1
6
3
1K 1
050-0R9A070J/JH
6
3
040-0R8A100J/JH
100 1
6
3
10 1
6
3
1
1K
3
6
1
10K
3
6
1
100K
3
6
1
1M
Frequency (Hz)
3
6
1
10M
3
30M
Notes on Use
Shelf Life
• Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use.
Storage Condition
• Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external
electrode.
• Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the
solderability of external electrode.
• Avoid storage near strong magnetic field, as such condition may magnetize the product.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0014_SCR • 6/16/2014
3
AC Line Filters – SCR Coils, High Impedance Type
KEMET Corporation
World Headquarters
Europe
Asia
Southern Europe
Paris, France
Tel: 33-1-4646-1006
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
Sasso Marconi, Italy
Tel: 39-051-939111
Shenzhen, China
Tel: 86-755-2518-1306
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Central Europe
Landsberg, Germany
Tel: 49-8191-3350800
Corporate Offices
Fort Lauderdale, FL
Tel: 954-766-2800
Kamen, Germany
Tel: 49-2307-438110
North America
Northern Europe
Bishop’s Stortford, United Kingdom
Tel: 44-1279-460122
2835 KEMET Way
Simpsonville, SC 29681
Southeast
Lake Mary, FL
Tel: 407-855-8886
Espoo, Finland
Tel: 358-9-5406-5000
Northeast
Wilmington, MA
Tel: 978-658-1663
Beijing, China
Tel: 86-10-5829-1711
Shanghai, China
Tel: 86-21-6447-0707
Taipei, Taiwan
Tel: 886-2-27528585
Southeast Asia
Singapore
Tel: 65-6586-1900
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Central
Novi, MI
Tel: 248-306-9353
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0014_SCR • 6/16/2014
4
AC Line Filters – SCR Coils, High Impedance Type
Disclaimer
This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market
and product offerings for both companies and their respective customers. For more information, please visit http://www.kemet.com/nectokin.
Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare
notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not
be required.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0014_SCR • 6/16/2014
5