AC Line Filters Large SCR Series, SCR47 Type Overview Applications The KEMET SCR47 Type AC line filters feature high inductance and high impedance characteristics. • Power Conditioner • Air Conditioner • Common mode choke eries ) Benefits • High inductance and high impedance characteristics support large electrical currents. • Industry’s highest standard, high permeability core. • Inductances up to 1.6 mH • Rated Currents up to 40 A • DC Resistances as low as 1.8 mΩ 7 Type Applications ●Power conditioner ●Air conditioner ance characteristics Part Number System rrents as a result of using SCR47- 400- 1R9 B 008 JH Type Rated Current AC (A) Wire Diameter (mm) Windings Minimum Inductance (mH) Orientation 1R6 = 1.6 1R9 = 1.9 C = Triple permeability core SCR47- Inductance (mH) min. 1.6 0.8 350- = 35.0 400- = 40.0 DC resistance (Ω/line) max. 3.5 1.8 Temperature rise (K) max. 70 50 008 = 0.8 016 = 1.6 Wire size (mmφ) 1.6×3P 1.9×3P J = Vertical JH = Horizontal Weight approx. (g) 200 230 • Insulation resistance: at500VDC, more than 100MΩ (between lines) ture range (℃): –25 to T (T=120 –temperature rise) • Inductance measurement condition: 10kHz, 1mA voltage: 2400VAC (2sec. between lines) © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com ●JH-TYPE One world. One KEMET LF0004_SCR47 • 6/16/2014 1 AC Line Filters – Large SCR Series, SCR47 Type Dimensions – Millimeters JH-Type J-Type SCR47-400-1R9C008JH 39 Maximum (25) 10 ±5 N2 38 Maximum 6 ±2 (44) N1 N2 (32) N1 ø 70 Maximum (44) (28) 59 Maximum 61 Maximum (32) SCR47-350-1R6C016J (28) (25) Environmental Compliance All KEMET AC Line Filters are RoHS Compliant. Table 1 – Ratings & Part Number Reference DC Resistance/ Inductance Line (mΩ) (mH) Minimum Maximum Part Number Rated Current AC (A) SCR47-350-1R6C016J 35 1.6 3.5 SCR47-400-1R9C008JH 40 0.8 1.8 Temperature Rise (K) Maximum Wire Diameter (mm) Weight (g) Approximate 70 1.6 x 3P 200 50 1.9 x 3P 230 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0004_SCR47 • 6/16/2014 2 • Thermal class: E (120℃) • Operating temperature range (℃): –25 to T (T=120 –temperature rise) • Inductance measurement condition: 10kHz, 1mA Shape and Dimensions AC Line Filters – Large SCR Series, SCR47 Type ●J-TYPE ●JH-TYPE SCR47-350-1R6C016J SCR47-400-1R9C008JH Specifications 61max (25) 39max ø70max. (44) (44) SCR47 59max N1 250 VAC/VDC N2 (28) Rated Voltage N1 2400 VAC (2 seconds, between lines) Insulation Resistance > 100 MΩ @ 500 VDC (between lines) Thermal Class E (120°C) N2 (32) Withstanding Voltage 10±5 6±2 (32) Item 38max. Operating Temperature Range -25ºC to T (T = 120 - temperature rise) (28) (25) Inductance Measurement Condition 10 kHz, 1 mA [mm] Frequency Characteristics Frequency characteristic 10K 1 SCR47-350-1R6C016J 6 Impedance () 3 1K 1 6 SCR47-400-1R9C008JH 3 100 1 6 3 10 1 6 3 1 1K 3 6 1 10K 3 6 1 100K 3 6 1 1M 3 6 1 10M 3 30M Frequency (Hz) Notes on Use Shelf Life • Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use. AC Line Filters Storage Condition • Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external electrode. • Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the solderability of external electrode. • Avoid storage near strong magnetic field, as such condition may magnetize the product. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0004_SCR47 • 6/16/2014 9 3 AC Line Filters – Large SCR Series, SCR47 Type KEMET Corporation World Headquarters Europe Asia Southern Europe Paris, France Tel: 33-1-4646-1006 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Sasso Marconi, Italy Tel: 39-051-939111 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg, Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Bishop’sStortford,UnitedKingdom Tel: 44-1279-460122 2835 KEMET Way Simpsonville, SC 29681 Southeast Lake Mary, FL Tel: 407-855-8886 Espoo, Finland Tel: 358-9-5406-5000 Northeast Wilmington, MA Tel: 978-658-1663 Beijing, China Tel: 86-10-5829-1711 Shanghai, China Tel: 86-21-6447-0707 Taipei, Taiwan Tel: 886-2-27528585 Southeast Asia Singapore Tel: 65-6586-1900 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 Central Novi, MI Tel: 248-306-9353 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0004_SCR47 • 6/16/2014 4 AC Line Filters – Large SCR Series, SCR47 Type Disclaimer This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market andproductofferingsforbothcompaniesandtheirrespectivecustomers.Formoreinformation,pleasevisithttp://www.kemet.com/nectokin. Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand verifyingtheextenttowhichtheInformationcontainedinthispublicationisapplicabletoanorderatthetimetheorderisplaced. AllInformationgivenhereinisbelievedtobeaccurateandreliable,butitispresentedwithoutguarantee,warranty,orresponsibilityofanykind,expressedorimplied. StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly bycustomerswhohavetherequisiteexperienceandcapabilitytodeterminethecorrectproductsfortheirapplication.AnytechnicaladviceinferredfromthisInformationorotherwise providedbyKEMETwithreferencetotheuseofKEMET’sproductsisgivengratis,andKEMETassumesnoobligationorliabilityfortheadvicegivenorresultsobtained. AlthoughKEMETdesignsandmanufacturesitsproductstothemoststringentqualityandsafetystandards,giventhecurrentstateoftheart,isolatedcomponentfailuresmaystill occur.Accordingly,customerapplicationswhichrequireahighdegreeofreliabilityorsafetyshouldemploysuitabledesignsorothersafeguards(suchasinstallationofprotective circuitryorredundancies)inordertoensurethatthefailureofanelectricalcomponentdoesnotresultinariskofpersonalinjuryorpropertydamage. Althoughallproduct–relatedwarnings,cautionsandnotesmustbeobserved,thecustomershouldnotassumethatallsafetymeasuresareindictedorthatothermeasuresmaynot be required. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0004_SCR47 • 6/16/2014 5