SCR47-400-1R9C008JH

AC Line Filters
Large SCR Series, SCR47 Type
Overview
Applications
The KEMET SCR47 Type AC line filters feature high inductance
and high impedance characteristics.
• Power Conditioner
• Air Conditioner
• Common mode choke
eries
)
Benefits
• High inductance and high impedance characteristics support
large electrical currents.
• Industry’s highest standard, high permeability core.
• Inductances up to 1.6 mH
• Rated Currents up to 40 A
• DC Resistances as low as 1.8 mΩ
7 Type
Applications
●Power conditioner ●Air conditioner
ance characteristics
Part Number System
rrents as a result of using
SCR47-
400-
1R9
B
008
JH
Type
Rated Current AC (A)
Wire Diameter (mm)
Windings
Minimum Inductance (mH)
Orientation
1R6 = 1.6
1R9 = 1.9
C = Triple
permeability core
SCR47-
Inductance
(mH)
min.
1.6
0.8
350- = 35.0
400- = 40.0
DC resistance
(Ω/line)
max.
3.5
1.8
Temperature
rise (K)
max.
70
50
008 = 0.8
016 = 1.6
Wire size
(mmφ)
1.6×3P
1.9×3P
J = Vertical
JH = Horizontal
Weight
approx.
(g)
200
230
• Insulation resistance: at500VDC, more than 100MΩ (between lines)
ture range (℃): –25 to T (T=120 –temperature rise)
• Inductance measurement condition: 10kHz, 1mA
voltage: 2400VAC (2sec. between lines)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
●JH-TYPE
One world. One KEMET
LF0004_SCR47 • 6/16/2014
1
AC Line Filters – Large SCR Series, SCR47 Type
Dimensions – Millimeters
JH-Type
J-Type
SCR47-400-1R9C008JH
39 Maximum
(25)
10 ±5
N2
38 Maximum
6 ±2
(44)
N1
N2
(32)
N1
ø 70 Maximum
(44)
(28)
59 Maximum
61 Maximum
(32)
SCR47-350-1R6C016J
(28)
(25)
Environmental Compliance
All KEMET AC Line Filters are RoHS Compliant.
Table 1 – Ratings & Part Number Reference
DC Resistance/
Inductance
Line (mΩ)
(mH) Minimum
Maximum
Part Number
Rated Current
AC (A)
SCR47-350-1R6C016J
35
1.6
3.5
SCR47-400-1R9C008JH
40
0.8
1.8
Temperature
Rise (K)
Maximum
Wire Diameter
(mm)
Weight (g)
Approximate
70
1.6 x 3P
200
50
1.9 x 3P
230
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0004_SCR47 • 6/16/2014
2
• Thermal class: E (120℃)
• Operating temperature range (℃): –25 to T (T=120 –temperature rise)
• Inductance measurement condition: 10kHz, 1mA
Shape and Dimensions
AC
Line Filters – Large SCR Series, SCR47 Type
●J-TYPE
●JH-TYPE
SCR47-350-1R6C016J
SCR47-400-1R9C008JH
Specifications
61max
(25)
39max
ø70max.
(44)
(44)
SCR47
59max
N1
250 VAC/VDC
N2
(28)
Rated Voltage
N1
2400 VAC (2 seconds, between lines)
Insulation Resistance
> 100 MΩ @ 500 VDC (between lines)
Thermal Class
E (120°C)
N2
(32)
Withstanding Voltage
10±5
6±2
(32)
Item
38max.
Operating Temperature Range
-25ºC to T (T = 120 - temperature rise)
(28)
(25)
Inductance Measurement Condition
10 kHz, 1 mA
[mm]
Frequency Characteristics
Frequency characteristic
10K 1
SCR47-350-1R6C016J
6
Impedance ()
3
1K 1
6
SCR47-400-1R9C008JH
3
100 1
6
3
10 1
6
3
1
1K
3
6
1
10K
3
6
1
100K
3
6
1
1M
3
6
1
10M
3
30M
Frequency (Hz)
Notes on Use
Shelf Life
• Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use.
AC Line Filters
Storage Condition
• Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external
electrode.
• Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the
solderability of external electrode.
• Avoid storage near strong magnetic field, as such condition may magnetize the product.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0004_SCR47 • 6/16/2014
9
3
AC Line Filters – Large SCR Series, SCR47 Type
KEMET Corporation
World Headquarters
Europe
Asia
Southern Europe
Paris, France
Tel: 33-1-4646-1006
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
Sasso Marconi, Italy
Tel: 39-051-939111
Shenzhen, China
Tel: 86-755-2518-1306
www.kemet.com
Tel: 864-963-6300
Fax: 864-963-6521
Central Europe
Landsberg, Germany
Tel: 49-8191-3350800
Corporate Offices
Fort Lauderdale, FL
Tel: 954-766-2800
Kamen, Germany
Tel: 49-2307-438110
North America
Northern Europe
Bishop’sStortford,UnitedKingdom
Tel: 44-1279-460122
2835 KEMET Way
Simpsonville, SC 29681
Southeast
Lake Mary, FL
Tel: 407-855-8886
Espoo, Finland
Tel: 358-9-5406-5000
Northeast
Wilmington, MA
Tel: 978-658-1663
Beijing, China
Tel: 86-10-5829-1711
Shanghai, China
Tel: 86-21-6447-0707
Taipei, Taiwan
Tel: 886-2-27528585
Southeast Asia
Singapore
Tel: 65-6586-1900
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
Central
Novi, MI
Tel: 248-306-9353
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0004_SCR47 • 6/16/2014
4
AC Line Filters – Large SCR Series, SCR47 Type
Disclaimer
This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market
andproductofferingsforbothcompaniesandtheirrespectivecustomers.Formoreinformation,pleasevisithttp://www.kemet.com/nectokin.
Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand
verifyingtheextenttowhichtheInformationcontainedinthispublicationisapplicabletoanorderatthetimetheorderisplaced.
AllInformationgivenhereinisbelievedtobeaccurateandreliable,butitispresentedwithoutguarantee,warranty,orresponsibilityofanykind,expressedorimplied.
StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare
notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly
bycustomerswhohavetherequisiteexperienceandcapabilitytodeterminethecorrectproductsfortheirapplication.AnytechnicaladviceinferredfromthisInformationorotherwise
providedbyKEMETwithreferencetotheuseofKEMET’sproductsisgivengratis,andKEMETassumesnoobligationorliabilityfortheadvicegivenorresultsobtained.
AlthoughKEMETdesignsandmanufacturesitsproductstothemoststringentqualityandsafetystandards,giventhecurrentstateoftheart,isolatedcomponentfailuresmaystill
occur.Accordingly,customerapplicationswhichrequireahighdegreeofreliabilityorsafetyshouldemploysuitabledesignsorothersafeguards(suchasinstallationofprotective
circuitryorredundancies)inordertoensurethatthefailureofanelectricalcomponentdoesnotresultinariskofpersonalinjuryorpropertydamage.
Althoughallproduct–relatedwarnings,cautionsandnotesmustbeobserved,thecustomershouldnotassumethatallsafetymeasuresareindictedorthatothermeasuresmaynot
be required.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
LF0004_SCR47 • 6/16/2014
5