AC Line Filters SS Coils, SS20H Type Overview Applications The KEMET SS Coils, SS20H Type AC line filters are offered in a wide variety of sizes and specifications. • Consumer Electronics • Common mode choke Benefits • • • • Wide variety of sizes and specifications Inductances up to 66 mH Rated Currents up to 2 A DC Resistances as low as 0.11 Ω Part Number System SS 20 H- R 03 660 Series Core Size (mm) Core Orientation Core Type Rated Current (A) Minimum Inductance (mH) SS 20 = 20.0 H- = Horizontal Blank = Standard R = High permeability 0x = 0.x A (e.g., 03 = 0.3 A) xx = x.x A (e.g., 13 = 1.3 A) xx0 = xx mH (e.g., 660 = 66 mH) 0xx = x.x mH (e.g., 052 = 5.2 mH) © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com One world. One KEMET LF0027_SS20H • 6/16/2014 1 AC Line Filters – SS Coils, SS20H Type Dimensions – Millimeters Marking 22 Maximum 13 10 18.5 Maximum 13 ±0.5 3.5 ±1.0 ø0.8 22 Maximum 10 ±0.5 Environmental Compliance All KEMET AC Line Filters are RoHS Compliant. Table 1 – Ratings & Part Number Reference Part Number Rated Current AC (A) Inductance (mH) Minimum DC Resistance/ Line (Ω) Maximum Temperature Rise (K) Maximum Marking Weight (g) Approximate SS20H-03510 SS20H-04340 SS20H-05270 SS20H-06150 SS20H-07130 SS20H-08100 SS20H-10080 SS20H-12050 SS20H-13044 SS20H-15029 SS20H-20018 SS20H-R03660 SS20H-R04450 SS20H-R05350 SS20H-R06200 SS20H-R07160 SS20H-R08125 SS20H-R10100 SS20H-R12063 SS20H-R13052 SS20H-R15033 SS20H-R20023 0.3 0.4 0.5 0.6 0.7 0.8 1.0 1.2 1.3 1.5 2.0 0.3 0.4 0.5 0.6 0.7 0.8 1.0 1.2 1.3 1.5 2.0 51 34 27 15 13 10 8.0 5.0 4.4 2.9 1.8 66 45 35 20 16 12.5 10 6.3 5.2 3.3 2.3 3.2 2.0 1.5 0.93 0.75 0.66 0.42 0.36 0.25 0.19 0.11 3.2 2.0 1.5 0.93 0.75 0.66 0.42 0.36 0.25 0.19 0.11 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 03 Lot No. 04 Lot No. 05 Lot No. 06 Lot No. 07 Lot No. 08 Lot No. 10 Lot No. 12 Lot No. 13 Lot No. 15 Lot No. 20 Lot No. R03 Lot No. R04 Lot No. R05 Lot No. R06 Lot No. R07 Lot No. R08 Lot No. R10 Lot No. R12 Lot No. R13 Lot No. R15 Lot No. R20 Lot No. 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 12.0 © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0027_SS20H • 6/16/2014 2 AC Line Filters – SS Coils, SS20H Type Specifications Item SS20H Rated Voltage 250 VAC Withstanding Voltage 2400 VAC (2 seconds, between lines) Insulation Resistance > 100 MΩ @ 500 VDC (between lines) Thermal Class E (120°C) Operating Temperature Range -25ºC to T (T = 120 - temperature rise) Inductance Measurement Condition 1 kHz, 1 V, KC530 Common mode Frequency Characteristics Frequency characteristic 1M 1 1M 1 6 3 03510 10K 1 6 3 07130 1K 1 6 3 06150 100 1 6 3 05270 10 1 6 3 1 1K 6 1 3 10K 6 1 3 6 100K 1 3 6 1M 1 10M Frequency (Hz) 30M 20018 6 3 15029 6 3 13044 3 6 1 3 10K 6 1 3 6 100K 1 3 6 1M 1 10M Frequency (Hz) 6 3 3 30M R10100 100K 1 R03660 Impedance () Impedance () 08100 100 1 1 1K R04450 6 3 R07160 1K 1 6 3 R05350 100 1 R06200 6 3 10 1 1 1K 6 3 1K 1 6 3 3 100K 1 6 3 10K 1 1M 1 6 3 10K 1 10080 6 3 10 1 3 1M 1 6 3 12050 100K 1 Impedance () Impedance () 100K 1 6 3 6 3 04340 6 3 R12063 10K 1 6 3 R08125 1K 1 R20023 6 3 100 1 R15033 6 3 R13052 10 1 3 6 1 10K 3 6 1 100K 3 6 1 1M Frequency (Hz) 3 6 1 10M 3 30M 6 3 1 1K 3 6 1 10K 3 6 1 100K 3 6 1 1M Frequency (Hz) 3 6 1 10M 3 30M Notes on Use Shelf Life • Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use. Storage Condition • Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external electrode. • Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the solderability of external electrode. • Avoid storage near strong magnetic field, as such condition may magnetize the product. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0027_SS20H • 6/16/2014 3 AC Line Filters – SS Coils, SS20H Type KEMET Corporation World Headquarters Europe Asia Southern Europe Paris, France Tel: 33-1-4646-1006 Northeast Asia Hong Kong Tel: 852-2305-1168 Mailing Address: P.O. Box 5928 Greenville, SC 29606 Sasso Marconi, Italy Tel: 39-051-939111 Shenzhen, China Tel: 86-755-2518-1306 www.kemet.com Tel: 864-963-6300 Fax: 864-963-6521 Central Europe Landsberg, Germany Tel: 49-8191-3350800 Corporate Offices Fort Lauderdale, FL Tel: 954-766-2800 Kamen, Germany Tel: 49-2307-438110 North America Northern Europe Bishop’s Stortford, United Kingdom Tel: 44-1279-460122 2835 KEMET Way Simpsonville, SC 29681 Southeast Lake Mary, FL Tel: 407-855-8886 Espoo, Finland Tel: 358-9-5406-5000 Northeast Wilmington, MA Tel: 978-658-1663 Beijing, China Tel: 86-10-5829-1711 Shanghai, China Tel: 86-21-6447-0707 Taipei, Taiwan Tel: 886-2-27528585 Southeast Asia Singapore Tel: 65-6586-1900 Penang, Malaysia Tel: 60-4-6430200 Bangalore, India Tel: 91-806-53-76817 Central Novi, MI Tel: 248-306-9353 West Milpitas, CA Tel: 408-433-9950 Mexico Guadalajara, Jalisco Tel: 52-33-3123-2141 Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of KEMET Electronics Corporation. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0027_SS20H • 6/16/2014 4 AC Line Filters – SS Coils, SS20H Type Disclaimer This product has been made available through a Private Label Agreement and a Development and Cross-Licensing Agreement between KEMET and NEC TOKIN to expand market and product offerings for both companies and their respective customers. For more information, please visit http://www.kemet.com/nectokin. Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. StatementsofsuitabilityforcertainapplicationsarebasedonKEMETElectronicsCorporation’s(“KEMET”)knowledgeoftypicaloperatingconditionsforsuchapplications,butare notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. © KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com LF0027_SS20H • 6/16/2014 5