LSU-12V - Pairui

Constant voltage LED Drivers
For indoor use
LSU-12V Series, 12Watt
FEATURES:
Constant voltage output
Cooling by free air convection
Short circuit, over voltage protections
IP30 rating
Class
Ⅱ, no FG
100% burn-in test
2 year warranty
Model
LSU12-V5
LSU12-V12
LSU12-V15
LSU12-V24
Input voltage
(Vac)
90-264
Output voltage
(Vdc)
Output current
(mA)
Output power
(W)
Min.
Max.
5
0
2000
10
12
0
1000
12
15
0
800
12
24
0
500
12
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Input voltage
Vin
--
Input frequency
Fline
Input current
Min.
Typ.
Max.
Units
90
--
264
Vac
120
--
370
Vdc
--
47
--
63
Hz
Full load, Vin =115Vac
--
0.35
A
Full load, Vin =230Vac
--
0.2
A
Iin
Inrush current
Iinrush
Cold start, Vin =230Vac
--
70
--
A
Leakage current
Ileakage
Vin =240Vac
--
0.25
--
mA
η
Full voltage, full load
76
82
--
%
LSU12-V5
0
--
2000
mA
LSU12-V12
0
--
1000
mA
LSU12-V15
0
--
800
mA
LSU12-V24
0
--
500
mA
Efficiency
Output
Output current
www.pairuigroup.com
Iout
Page: 1 / 3
Date: 07/17/2015
Constant voltage LED Drivers
For indoor use
LSU-12V Series, 12Watt
ELECTRICAL
Output
Parameters
Test Conditions / Comment
Min.
Typ.
Max.
Units
LSU12-V5
4.75
5
5.25
V
LSU12-V12
11.4
12
12.6
V
LSU12-V15
14.25
15
15.75
V
LSU12-V24
22.8
24
25.2
V
--
--
--
±5.0
--
%
Line regulation
Iout-line
--
--
±1.0
--
%
Load regulation
Iout-load
--
--
±2.0
--
%
Full load, Vin =115Vac
--
--
mS
Full load, Vin =230Vac
--
--
mS
LSU12-V5
--
--
100
mVp-p
LSU12-V12
--
--
120
mVp-p
LSU12-V15
--
--
120
mVp-p
LSU12-V24
--
--
150
mVp-p
Output voltage
Output voltage accuracy
Turn-on, rise time
Ripple
Symbols
Vout
--
Vripple
1500,
30
1500,
30
Protection
Over load
Short circuit
>105% rated output power
Hiccup mode, it will recover automatically after fault condition is removed
Hiccup mode, it will recover automatically after fault conditions is removed
Environment
Storage
Ambient operating
temperature
Operating relative humidity
MTBF
Temperature coefficient
Tstorage
Ta
Humidity: 10% RH to 95% RH
Startup at rated voltage
(required Derating)
Ha
TMTBF
--
--
+80
℃
-30
--
+70
℃
20
--
90
%
400
--
--
kHrs
--
±0.2
--
%
Non condensing
Full load, 220Vac input,
℃ ambient temperature
0~50℃
25
Dimension(LxWxH)
www.pairuigroup.com
-40
77 x 40 x 29mm
Page: 2 / 3
Date: 07/17/2015
Constant voltage LED Drivers
For indoor use
LSU-12V Series, 12Watt
ELECTRICAL
Safety / EMC
Safety standards
EN61347-1, EN61347-2-13
EMC
EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547
℃
Notes: 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and
Vin = 230Vac, rated load;
2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF
& 47μF parallel capacitor.
MECHANICAL
Unit: mm
ELECTRICAL CURVE
DERATING CURVE
www.pairuigroup.com
STATIC CHARACTERISTICS
Page: 3 / 3
Date: 07/17/2015