Constant voltage LED Drivers For outdoor use LEU-60V Series, 60Watt FEATURES: Constant voltage output Universal AC input/ Full range Withstand inrush voltage 300Vac within 5 seconds Short circuit, and over voltage protections IP67 rated Class , no FG Pass LPS (Limited Power Source) Test Application for LED lighting and electronic screen 100% burn-in test High reliability 2 year warranty Cooling by free air convection Ⅱ Model Input voltage (Vac) Output voltage (Vdc) Output current (A) Output power (W) Min. Max. 5 0 8 40 12 0 5 60 15 0 4 60 24 0 2.5 60 LEU60-V36 36 0 1.67 60 LEU60-V48 48 0 1.25 60 LEU60-V5 LEU60-V12 LEU60-V15 LEU60-V24 90-264 ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin --- 90 -- 264 Vac Input frequency Fline --- 47 -- 63 Hz Full load, Vin =115Vac -- 1.2 -- A Full load, Vin =230Vac -- 1 -- A Iinrush Cold start, Vin =230Vac -- 60 -- A η Full voltage, full load -- 83 -- % Input current Inrush current Efficiency www.pairuigroup.com Iin Page: 1 / 5 Date: 07/18/2015 Constant voltage LED Drivers For outdoor use LEU-60V Series, 60Watt ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Leakage current Ileakage Vin =230Vac -- 0.25 -- mA LEU60-V5 0 -- 8 A LEU60-V12 0 -- 5 A LEU60-V15 0 -- 4 A LEU60-V24 0 -- 2.5 A LEU60-V36 0 -- 1.67 A LEU60-V48 0 -- 1.25 A LEU60-V5 -- 5 -- V LEU60-V12 -- 12 -- V LEU60-V15 -- 15 -- V LEU60-V24 -- 24 -- V LEU60-V36 -- 36 -- V LEU60-V48 -- 48 -- V -- --- -- ±5 -- % Line regulation Vout-line --- -- ±1.0 -- % Load regulation Vout-load --- -- ±2.0 -- % Turn-on delay time Ton_delay Full voltage, full load -- 500 -- ms Ton_rise Full voltage, full load -- 20 -- ms Vin =115Vac, full load -- 16 -- ms Vin =230Vac, full load -- 50 -- ms Vripple --- -- 5%Vo -- mVp-p -- Vin =115Vac, output load≥50% -- -- 20 % Output Output current Output voltage Output voltage accuracy Rise time Hold-on time Ripple THD www.pairuigroup.com Iout Vout -- Page: 2 / 5 Date: 07/18/2015 Constant voltage LED Drivers For outdoor use LEU-60V Series, 60Watt ELECTRICAL Protection Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Over current Typical:110-150%; Hiccup mode, it will auto-recovery after fault condition is removed Over voltage Typical:110-150%; Hiccup mode, it will auto-recovery after fault condition is removed Environment Storage Ambient operating temperature Temperature coefficient Operating relative humidity MTBF Tstorage Humidity: 5% RH to 95% RH Startup at rated voltage Ta (Please refer to derating curve) -40 -- +80 ℃ -30 -- +70 ℃ -- --- -- 300 -- ppm Ha Non condensing 10 -- 95 % -- 732 -- kHrs TMTBF Dimension(LxWxH) Full load, 220Vac input, 25 ℃ ambient temperature 162.5 x 42.5 x 32.0mm Weight 400g Safety / EMC Safety standards UL879, UL1310, TUV EN60950-1, IP67 Withstand voltage I/P-O/P:3KVAC Insulation resistance I/P-O/P: 100M Ohms/500VDC/25 /70%RH EMC emission Design to EN55022(CISPR22)Class B, EN61000-3-2 Class A, EN61000-3-3 EMC immunity Design to EN61000-4-2,3,4,5,6,8,11, EN55024 > ℃ ℃ Notes: 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and Vin = 230Vac, rated load; 2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor; 3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes. www.pairuigroup.com Page: 3 / 5 Date: 07/18/2015 Constant voltage LED Drivers For outdoor use LEU-60V Series, 60Watt MECHANICAL Unit: mm RECOMMEND INSTALLATION BLOCK DIAGRAM www.pairuigroup.com Page: 4 / 5 Date: 07/18/2015 Constant voltage LED Drivers For outdoor use LEU-60V Series, 60Watt ELECTRICAL CURVE DERATING CURVE www.pairuigroup.com STATIC CHARACTERISTIC CURVE Page: 5 / 5 Date: 07/18/2015