LEU-100V

Constant voltage LED Drivers
For outdoor use
LEU-100V Series, 100Watt
FEATURES:
Constant voltage output
Universal AC input/ Full range
Withstand inrush voltage 300Vac within 5 seconds
Short circuit, and over voltage protections
IP67 rated
Class , no FG
Pass LPS (Limited Power Source) Test
Application for LED lighting and electronic screen
100% burn-in test
High reliability
2 year warranty
Cooling by free air convection
Ⅱ
Model
Input voltage
(Vac)
Output voltage
(Vdc)
Output current
(A)
Output power
(W)
Min.
Max.
5
0
12
60
12
0
8.5
102
15
0
6.7
100.5
24
0
4.2
100.8
LEU100-V36
36
0
2.8
100.8
LEU100-V48
48
0
2.1
100.8
LEU100-V5
LEU100-V12
LEU100-V15
LEU100-V24
90-264
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
---
90
--
264
Vac
Input frequency
Fline
---
47
--
63
Hz
Full load, Vin =115Vac
--
2.2
--
A
Full load, Vin =230Vac
--
1.2
--
A
Iinrush
Cold start, Vin =230Vac
--
75
--
A
η
Full voltage, full load
--
87
--
%
Ileakage
Vin =230Vac
--
0.25
--
mA
Input current
Inrush current
Efficiency
Leakage current
www.pairuigroup.com
Iin
Page: 1 / 4
Date: 07/18/2015
Constant voltage LED Drivers
For outdoor use
LEU-100V Series, 100Watt
ELECTRICAL
Output
Parameters
Test Conditions / Comment
Min.
Typ.
Max.
Units
LEU100-V5
0
--
12
A
LEU100-V12
0
--
8.5
A
LEU100-V15
0
--
6.7
A
LEU100-V24
0
--
4.2
A
LEU100-V36
0
--
2.8
A
LEU100-V48
0
--
2.1
A
LEU100-V5
--
5
--
V
LEU100-V12
--
12
--
V
LEU100-V15
--
15
--
V
LEU100-V24
--
24
--
V
LEU100-V36
--
36
--
V
LEU100-V48
--
48
--
V
--
---
--
±5
--
%
Line regulation
Vout-line
---
--
±1.0
--
%
Load regulation
Vout-load
---
--
±2.0
--
%
Turn-on delay time
Ton_delay
Full voltage, full load
--
2000
--
ms
Ton_rise
Full voltage, full load
--
25
--
ms
Vin =115Vac, full load
--
14
--
ms
Vin =230Vac, full load
--
50
--
ms
Vripple
---
--
5%Vo
--
mVp-p
--
Vin =115Vac, output load≥50%
--
--
20
%
Output current
Output voltage
Output voltage accuracy
Rise time
Hold-on time
Ripple
THD
Symbols
Iout
Vout
--
Protection
Over current
Typical:110-150%; Hiccup mode, it will auto-recovery after fault condition is removed
Over voltage
Typical:110-150%; Hiccup mode, it will auto-recovery after fault condition is removed
www.pairuigroup.com
Page: 2 / 4
Date: 07/18/2015
Constant voltage LED Drivers
For outdoor use
LEU-100V Series, 100Watt
ELECTRICAL
Environment
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Storage
Tstorage
Humidity: 5% RH to 95% RH
-40
--
+80
℃
-25
--
+70
℃
Ambient operating
temperature
Temperature coefficient
Operating relative
humidity
MTBF
Startup at rated voltage
Ta
(Please refer to derating curve)
--
---
--
300
--
ppm
Ha
Non condensing
10
--
95
%
--
700
--
kHrs
TMTBF
Full load, 220Vac input,
℃
25
Dimension(LxWxH)
ambient temperature
190.0 x 52.0 x 37.0mm
Weight
630g
Safety / EMC
Safety standards
TUV EN60950-1, IP67
Withstand voltage
I/P-O/P:3KVAC
Insulation resistance
I/P-O/P: 100M Ohms/500VDC/25 /70%RH
EMC emission
Design to EN55022(CISPR22)Class B, EN61000-3-2 Class A, EN61000-3-3
EMC immunity
Design to EN61000-4-2,3,4,5,6,8,11, EN55024
>
℃
℃
Notes: 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25
and Vin = 230Vac, rated load;
2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF
& 47μF parallel capacitor;
3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more
than 30 minutes.
MECHANICAL
Unit: mm
www.pairuigroup.com
Page: 3 / 4
Date: 07/18/2015
Constant voltage LED Drivers
For outdoor use
LEU-100V Series, 100Watt
MECHANICAL
RECOMMEND INSTALLATION
BLOCK DIAGRAM
ELECTRICAL CURVE
DERATING CURVE
www.pairuigroup.com
STATIC CHARACTERISTIC CURVE
Page: 4 / 4
Date: 07/18/2015