F:\\\271\346\270\361\312\351\\00 LED driver\\LNS Series

Constant current LED Drivers
For indoor use
LNSU-12C Series, 12 Watt
FEATURES:
Constant current output
Universal AC input range: 90-264VAC
Active power factor correction, class Ⅱ power
Short circuit, over load and over temperature protections
Designed to worldwide safety standards for lighting
Cooling by free air convection
5 year warranty
Model
Nominal
Input voltage
(Vac)
LNSU12-C350
LNSU12-C500
100-240
LNSU12-C700
Output current
(mA)
Output voltage
(Vdc)
Output power
(W)
Min.
Max.
350
3
48
12
500
3
40
12
700
3
35
12
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
---
90
--
264
Vac
Input frequency
Fline
---
47
--
63
Hz
Input current
Iin
Full load, Vin = 100Vac
--
--
0.2
A
Inrush current
Iinrush
Cold start, 20μs
--
--
10
A
Power factor
PF
Full load
--
0.9
--
PF
η
Full voltage, full load
--
81
--
%
LNSU12-C350
332.5
350
367.5
mA
LNSU12-C500
475
500
525
mA
LNSU12-C700
665
700
735
mA
LNSU12-C350
3
34
48
V
LNSU12-C500
3
24
40
V
LNSU12-C700
3
17
35
V
Efficiency
Output
Output current
Output voltage
www.pairuigroup.com
Iout
Vout
Page: 1 / 4
Date: 12/31/2014
*Subject to change without prior notice.
Constant current LED Drivers
For indoor use
LNSU-12C Series, 12 Watt
ELECTRICAL
Output
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Turn-on time
Ton
Cold start, power on
--
--
0.5
S
LNSU12-C350
--
200
--
LNSU12-C500
--
250
--
LNSU12-C700
--
300
--
Ripple
--
mAp-p
Protection
Over voltage
Over temperature
Short circuit
The voltage will fluctuates in the vicinity of the protection value, it will recover automatically
after fault condition is removed
No output when exceeds temperature protection point, it will recover automatically after the
temperature falls below the threshold value
In hiccup mode, it will recover automatically after fault condition is removed
Environment
Storage
Ambient operating
temperature
Maximum case
temperature
Operating relative
humidity
MTBF
Tstorage
Humidity: 5% RH to 85% RH
-30
--
+80
℃
Ta
Startup at rated voltage
-20
--
+50
℃
Tc
Hot-spot on case
--
--
+80
℃
Ha
Non condensing
5
--
85
%
--
50
--
kHrs
TMTBF
℃
80
Full load,
ambient temperature
Waterproof
Dimension(LxWxH)
IP20
133 x 45 x 18mm
Weight
100g
Safety / EMC
Safety standards
Design refer to EN61347-1, EN61347-2-13, UL8750, UL1310, FCC15 Class B
EMC
Design refer to EN55015, EN61000-3-2, EN61547, EN62384, EN62493
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25
Vin = 100Vac to 240Vac.
www.pairuigroup.com
Page: 2 / 4
℃
and
Date: 12/31/2014
*Subject to change without prior notice.
Constant current LED Drivers
For indoor use
LNSU-12C Series, 12 Watt
MECHANICAL
Unit: mm
ELECTRICAL CURVE
PF vs Load
www.pairuigroup.com
Page: 3 / 4
Date: 12/31/2014
*Subject to change without prior notice.
Constant current LED Drivers
For indoor use
LNSU-12C Series, 12 Watt
ELECTRICAL CURVE
Efficiency vs Load
www.pairuigroup.com
Page: 4 / 4
Date: 12/31/2014
*Subject to change without prior notice.