SM 3000 Series

SM 3000 Series
Features
• Very low output ripple and spikes
• Stable output voltage or current
• Master / Slave parallel and series operation with
equal current and voltage sharing
• Input / output insulation 3750 Vrms
• Designed for long life at full power
• Voltage and current control with 10 turn potentiometers,
resolution 0.03 %
• Protected against all over load and short circ uit
conditions
• Low noise blower, fan speed adapts to temperature
• 0 - 5 V analog programmable both voltage and current
• Ethernet, RS232 or IEEE488 programming options
SELECTION TABLE
SM15-200 D
0 - 15 V
0 - 200 A
SM30-100 D
0 - 30 V
INPUT
SM45-70 D
0 - 100 A
0 - 45 V
0 - 70 A
SM70-45 D
0 - 70 V
0 - 45 A
SM120-25 D
0 - 120 V
SM300-10 D
0 - 25 A
0 - 300 V
0 - 10 A
SM 15-200D
SM 30-100D
SM 45-70D
SM 70-45D
SM 120-25D
SM 300-10D
342 - 457 V
342 - 457 V
342 - 457 V
342 - 457 V
342 - 457 V
342 - 457 V
5.7 Arms
5.5 Arms
5.8 Arms
5.8 Arms
5.5 Arms
5.5 Arms
0.88
0.78
0.88
0.78
0.88
0.78
0.88
0.78
0.88
0.78
0.88
0.78
contact
factory
contact
factory
contact
factory
contact
factory
contact
factory
contact
factory
16 AT
25 W
50 W
16 AT
25 W
50 W
16 AT
25 W
50 W
16 AT
25 W
50 W
16 AT
25 W
50 W
16 AT
25 W
50 W
AC 3 phase input, full load
87 %
90 %
89 %
90 %
90 %
90 %
Doc. No. PBC9 Rev.C 28-4-11
Powering Progress – www.powerbox.com.au
AC 3 phase, 48 - 62 Hz
For use at 380 V, 400 V, 415 V
Nominal line - line voltage
Current (400 V AC / 3 phase )
Power fac tor (380 V / 3 phase)
100% load
50% load
DC
Fuses
Standby input power (Vo=Io=0)
Standby input power (Vo=Vmax)
LABORATORY POWER SUPPLIES
3 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
EFFICIENCY
557
LABORATORY POWER SUPPLIES
SM 3000 Series
3 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
REGULATION
Load 0 - 100%
Line 342 - 457 V AC
Load 0 - 100%
Line 342 - 457 V AC
Ripple + noise, rms/p-p
CV
CV
CC
CC
CV
CC
Temp. coeff., per °C
CV
CC
typical10.10-6, max. 35.10-6
typical20.10-6, max. 60.10-6
CC
CC
CV
CC
typical 2.10-5, max 4.10-5
typical 3.10-5, max. 10.10-5
typical 2.10-5, max. 5.10-5
typical 5.10-5, max. 10.10-5
Stability
After 1 hr warm-up
During 8 hrs
5 mV
5 mV
50 mA
50 mA
2 / 12 mV
100 / 250 mA
5 mV
5 mV
25 mA
25 mA
1.6 / 8 mV
20 / 60 mA
During 30 hrs
ANALOG PROGRAMMING
Program ming inputs
Input range
Accuracy
Temp. coeff. offset
Input impedance
10 mV
10 mV
10 mA
10 mA
5 / 25 mV
7 / 25 mA
15 mV
10 mV
3 mA
3 mA
10 / 50 mV
below 50 V:
25 / 120 mV
3 / 10 mA
be low 50 V:
60 / 200 mA
CC
0-5V
± 0.2% 0 mV … + 8 mV (on 5V)
10 ␮V / °C
> 1 MOhm
0-5V
± 0.5% 0 mV … + 20 mV (on 5V)
150 ␮V / °C
> 1 MOhm
0-5V
± 0.2% - 3 mV … + 11 mV
10 ␮V / °C
> 20 MOhm
0-5V
± 0.5% - 5 mV … + 0 mV
150 ␮V / °C
> 20 MOhm
Monitoring output
Output range
Accuracy
Temp. coeff. off set
Output im pedance
Reference voltage
on prog. connector Vref
TC
Status outputs
CC - status
OVP- status
PROGRAMMING SPEED
STANDARD VERSION
10 mV
5 mV
10 mA
10 mA
2 / 12 mV
6 / 25 m A
CV
5.165 ± 31 mV
typical 12ppm / max. 30 ppm
5V / 10 mA = logic 1
5V / 10 mA = logic 1
Remote ShutDown
with + 5V or relay contact
SM 15-200 D
OPTION P104
SM 30-100 D
OPTION P031
SM 45-70 D
OPTION P1
SM 70-45 D
OPTION P032
SM120-25 D
OPTION P106
SM300-10D
OPTION P061
Rise time (10 - 90%)
Output voltage step
Time, (100 % load)
Time, (10 % load)
0  15 V
7 ms
7 ms
0  30 V
7 ms
7 ms
0  45 V
7 ms
7 ms
0  70 V
7 ms
7 ms
0  120 V
7 ms
7 ms
0  300 V
7 ms
7 ms
Fall time (90 - 10%)
Output voltage step
Time, (100 % load)
Time, (10 % load)
15  0 V
7 ms
32 ms
30  0 V
7 ms
58 ms
45  0 V
87 ms
29 ms
70  0 V
8 ms
82 ms
120  0 V
7 ms
39 ms
300  0 V
11 ms
91 ms
50 Hz
50 Hz
5 Hz
50 Hz
50 Hz
5 Hz
50 Hz
50 Hz
5 Hz
50 Hz
50 Hz
5 Hz
50 Hz
50 Hz
5 Hz
50 Hz
50 Hz
5 Hz
SM 15-200 D
option P104
SM 30-100 D
option P031
SM 45-70 D
option P105
SM 70-45 D
option P032
SM120-25 D
option P106
SM300-10D
option P061
0  15 V
0.36 ms
0.26 ms
0  30 V
0.33 ms
0.32 ms
0  45 V
0.50 ms
0.35 ms
0  70 V
0.45 ms
0.30 ms
0  120 V
0.34 ms
0.32 ms
0  300 V
1.00 ms
0.40 ms
15  0 V
0.37 ms
1.60 ms
30  0 V
0.55 ms
3.50 ms
45  0 V
0.60 ms
5.00 ms
70  0 V
0.67 ms
6.00 ms
120  0 V
0.38 ms
3.50 ms
300  0 V
1.20 ms
11.0 ms
Programming bandwidth
Small signal
Large signal,(100 % load)
Large signal,(10 % load)
Programming speed
High Speed Version
(resistive load)
Rise time (10 - 10%)
Output voltage step
Time, (100 % load)
Time, (10 % load)
Fall time (90 - 10%)
Output voltage step
Time, (100 % load)
Time, (10 % load)
558
5 mV
5 mV
15 mA
15 mA
3.5 / 17 mV
20 / 60 mA
Doc. No. PBC9 Rev.C 28-4-11
SM 3000 Series
Recovery time
Recovery within
Di/dt of load step
Output voltage
Time, @ 50 - 100% load step
Max.deviation
Noise suppression
Line - line = output
Line - earth output
Output impedance
CV, 0-100 kHz
Pulsating load
Max.tolerable AC component
of load current
f > 1 kHz
f < 1 kHz
50 mV
2.7 A/µs
100µs
250 mV
50 mV
1.9 A/µs
100µs
150 mV
100 mV
1.27 A/µs
100µs
150 mV
50 mV
2.2 A/µs
100µs
250 mV
0.50 V
1.7 A/µs
100µs
1.5 V
1.5V
0.6 A/µs
100µs
2V
90 dB
90 dB
84 dB
90 dB
85 dB
90 dB
75 dB
90 dB
75 dB
90 dB
90 dB
90 dB
< 25 mOhm
< 20 mOhm
< 60 mOhm
< 60 mOhm
< 150 mOhm
< 800 mOhm
15 Arms
200 Apeak
15 Arms
100 Apeak
10 Arms
70 Apeak
10 Arms
45 Apeak
5 Arms
25 Apeak
2.5 Arms
10 Apeak
Insulation
Input / output
Creepage / clearance
Input / case
Output / case
Safety
MC
Power supply stanadard
Generic emission
Generic immunity
3750 Vrms (1 min.)
8 mm
2500 Vrms
600 V DC
EN 60950 / EN 6 1010
EN 61204-3,
Emission: residential, light industrial environment (CISPR22-ClassB)
Immunity: industrial environment
EN 61000-6-3, residential, light industrial environment (EN55022B)
EN 61000-6-2,industrial environment
Operating temperature at full load
- 20 to + 50 °C
max. 95% RH, non condensing, up to 40 °C
max. 75% RH, non condensing, up to 50 °C
- 40 to + 85 °C
Humidity
Storage temperature
Thermal protection
Output shuts down in case of insufficient cooling
MTBF
500 000 hrs
Hold-Up Time
100% load
Vin = 3x 380 V AC
50% load
Vin = 3x 380 V AC
Turn on delay
After mains switch on
Inrush current
6 ms
15 ms
300ms
5.8 A @ 400 V AC in put
The power supply will continue to operate on one phase but at 90% of Vout(max)
(a SM30-100D adjusted at 27 V will continue to deliver 27 V after phase loss)
Phase loss
Series Operation
Max. total avoltage
Master / Slave Operation
Parallel Operation
Max. total avoltage
Master / Slave Operation
Remote sensing
Max. voltage drop per load lead
OVP / OVL
adjustment range
Potentionmeters & Encoders
Rront panel control with knobs
Resolution
Screwdriver adjustment
Digital encoders
Meters
Scale
Scale
Accuracy
LABORATORY POWER SUPPLIES
3 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
voltage
current
Doc. No. PBC9 Rev.C 28-4-11
SM 15-200D
SM30-100D
SM45-70 D
SM70-45D
SM120-25D
SM300-10D
600 V
yes
600 V
yes
600 V
yes
600 V
yes
600 V
yes
600 V
yes
no limit
max. 4 units
no limit
max. 4 units
no limit
max. 4 units
no limit
max. 4 units
no limit
max. 4 units
no limit
max. 4 units
2V
2V
2V
2V
2V
2V
0 - 17 V
0 - 35 V
0 - 54 V
0 - 80 V
0 - 140 V
0 - 350 V
standard
0.03 %
standard
0.03 %
standard
0.03 %
standard
0.03 %
standard
0.03 %
standard
0.03 %
option P001
option P002
option P001
option P002
option P001
option P002
option P001
option P002
option P001
option P002
option P001
option P002
3.5 digit
0 - 15.00 V
0 - 200 A
0.5% + 2 digit
3.5 digit
0 - 30.0 V
0 - 100.0 A
0.5% + 2 digit
3.5 digit
0 - 45.0 V
0 - 70.0 A
0.5% + 2 digit
3.5 digit
0 - 70.0 V
0 - 45.0 A
0.5% + 2 digit
3.5 digit
0 - 120.0 V
0 - 25.0 A
0.5% + 2 digit
3.5 digit
0 - 300 V
0 - 10.00 A
0.5% + 2 digit
Powering Progress – www.powerbox.com.au
559
LABORATORY POWER SUPPLIES
SM 3000 Series
560
3 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
Mounting
Input terminals
Input connections
Output terminals
Programming conector
Cooling
Audio noise level
Enclosure
Degree of protection
Dimensions
Behind front panel: h x w x d
Front panel: h x w
Weight
M10 bolts
Stacking of units allowed, air flow is from left to right
screw termials for cable 1.5 - 4.0mm2
3 phase + earth (no neutral required)
M10 bolts
M10 bolts
M8 bolts
7 mm bind
post
15 pole D-connector at rear panel (FEMALE)
6 mm bind
post
Low noise blower, fan speed adapts to temperature of internal heatsink.
ca. 50 dBA at full load and 25 °C ambient temperature
ca. 60 dBA at full load and 50 °C ambient temperatur
IP20
128.5 x 443 x 416 mm
128.5 x 483 mm (19", 3 U)
(with option P099, feet are removed)
15kg
Doc. No. PBC9 Rev.C 28-4-11
SM 3000 Series - Options
Doc. No. PBC9 Rev.C 28-4-11
Powering Progress – www.powerbox.com.au