SM 3000 Series Features • Very low output ripple and spikes • Stable output voltage or current • Master / Slave parallel and series operation with equal current and voltage sharing • Input / output insulation 3750 Vrms • Designed for long life at full power • Voltage and current control with 10 turn potentiometers, resolution 0.03 % • Protected against all over load and short circ uit conditions • Low noise blower, fan speed adapts to temperature • 0 - 5 V analog programmable both voltage and current • Ethernet, RS232 or IEEE488 programming options SELECTION TABLE SM15-200 D 0 - 15 V 0 - 200 A SM30-100 D 0 - 30 V INPUT SM45-70 D 0 - 100 A 0 - 45 V 0 - 70 A SM70-45 D 0 - 70 V 0 - 45 A SM120-25 D 0 - 120 V SM300-10 D 0 - 25 A 0 - 300 V 0 - 10 A SM 15-200D SM 30-100D SM 45-70D SM 70-45D SM 120-25D SM 300-10D 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 342 - 457 V 5.7 Arms 5.5 Arms 5.8 Arms 5.8 Arms 5.5 Arms 5.5 Arms 0.88 0.78 0.88 0.78 0.88 0.78 0.88 0.78 0.88 0.78 0.88 0.78 contact factory contact factory contact factory contact factory contact factory contact factory 16 AT 25 W 50 W 16 AT 25 W 50 W 16 AT 25 W 50 W 16 AT 25 W 50 W 16 AT 25 W 50 W 16 AT 25 W 50 W AC 3 phase input, full load 87 % 90 % 89 % 90 % 90 % 90 % Doc. No. PBC9 Rev.C 28-4-11 Powering Progress – www.powerbox.com.au AC 3 phase, 48 - 62 Hz For use at 380 V, 400 V, 415 V Nominal line - line voltage Current (400 V AC / 3 phase ) Power fac tor (380 V / 3 phase) 100% load 50% load DC Fuses Standby input power (Vo=Io=0) Standby input power (Vo=Vmax) LABORATORY POWER SUPPLIES 3 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY EFFICIENCY 557 LABORATORY POWER SUPPLIES SM 3000 Series 3 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY REGULATION Load 0 - 100% Line 342 - 457 V AC Load 0 - 100% Line 342 - 457 V AC Ripple + noise, rms/p-p CV CV CC CC CV CC Temp. coeff., per °C CV CC typical10.10-6, max. 35.10-6 typical20.10-6, max. 60.10-6 CC CC CV CC typical 2.10-5, max 4.10-5 typical 3.10-5, max. 10.10-5 typical 2.10-5, max. 5.10-5 typical 5.10-5, max. 10.10-5 Stability After 1 hr warm-up During 8 hrs 5 mV 5 mV 50 mA 50 mA 2 / 12 mV 100 / 250 mA 5 mV 5 mV 25 mA 25 mA 1.6 / 8 mV 20 / 60 mA During 30 hrs ANALOG PROGRAMMING Program ming inputs Input range Accuracy Temp. coeff. offset Input impedance 10 mV 10 mV 10 mA 10 mA 5 / 25 mV 7 / 25 mA 15 mV 10 mV 3 mA 3 mA 10 / 50 mV below 50 V: 25 / 120 mV 3 / 10 mA be low 50 V: 60 / 200 mA CC 0-5V ± 0.2% 0 mV … + 8 mV (on 5V) 10 V / °C > 1 MOhm 0-5V ± 0.5% 0 mV … + 20 mV (on 5V) 150 V / °C > 1 MOhm 0-5V ± 0.2% - 3 mV … + 11 mV 10 V / °C > 20 MOhm 0-5V ± 0.5% - 5 mV … + 0 mV 150 V / °C > 20 MOhm Monitoring output Output range Accuracy Temp. coeff. off set Output im pedance Reference voltage on prog. connector Vref TC Status outputs CC - status OVP- status PROGRAMMING SPEED STANDARD VERSION 10 mV 5 mV 10 mA 10 mA 2 / 12 mV 6 / 25 m A CV 5.165 ± 31 mV typical 12ppm / max. 30 ppm 5V / 10 mA = logic 1 5V / 10 mA = logic 1 Remote ShutDown with + 5V or relay contact SM 15-200 D OPTION P104 SM 30-100 D OPTION P031 SM 45-70 D OPTION P1 SM 70-45 D OPTION P032 SM120-25 D OPTION P106 SM300-10D OPTION P061 Rise time (10 - 90%) Output voltage step Time, (100 % load) Time, (10 % load) 0 15 V 7 ms 7 ms 0 30 V 7 ms 7 ms 0 45 V 7 ms 7 ms 0 70 V 7 ms 7 ms 0 120 V 7 ms 7 ms 0 300 V 7 ms 7 ms Fall time (90 - 10%) Output voltage step Time, (100 % load) Time, (10 % load) 15 0 V 7 ms 32 ms 30 0 V 7 ms 58 ms 45 0 V 87 ms 29 ms 70 0 V 8 ms 82 ms 120 0 V 7 ms 39 ms 300 0 V 11 ms 91 ms 50 Hz 50 Hz 5 Hz 50 Hz 50 Hz 5 Hz 50 Hz 50 Hz 5 Hz 50 Hz 50 Hz 5 Hz 50 Hz 50 Hz 5 Hz 50 Hz 50 Hz 5 Hz SM 15-200 D option P104 SM 30-100 D option P031 SM 45-70 D option P105 SM 70-45 D option P032 SM120-25 D option P106 SM300-10D option P061 0 15 V 0.36 ms 0.26 ms 0 30 V 0.33 ms 0.32 ms 0 45 V 0.50 ms 0.35 ms 0 70 V 0.45 ms 0.30 ms 0 120 V 0.34 ms 0.32 ms 0 300 V 1.00 ms 0.40 ms 15 0 V 0.37 ms 1.60 ms 30 0 V 0.55 ms 3.50 ms 45 0 V 0.60 ms 5.00 ms 70 0 V 0.67 ms 6.00 ms 120 0 V 0.38 ms 3.50 ms 300 0 V 1.20 ms 11.0 ms Programming bandwidth Small signal Large signal,(100 % load) Large signal,(10 % load) Programming speed High Speed Version (resistive load) Rise time (10 - 10%) Output voltage step Time, (100 % load) Time, (10 % load) Fall time (90 - 10%) Output voltage step Time, (100 % load) Time, (10 % load) 558 5 mV 5 mV 15 mA 15 mA 3.5 / 17 mV 20 / 60 mA Doc. No. PBC9 Rev.C 28-4-11 SM 3000 Series Recovery time Recovery within Di/dt of load step Output voltage Time, @ 50 - 100% load step Max.deviation Noise suppression Line - line = output Line - earth output Output impedance CV, 0-100 kHz Pulsating load Max.tolerable AC component of load current f > 1 kHz f < 1 kHz 50 mV 2.7 A/µs 100µs 250 mV 50 mV 1.9 A/µs 100µs 150 mV 100 mV 1.27 A/µs 100µs 150 mV 50 mV 2.2 A/µs 100µs 250 mV 0.50 V 1.7 A/µs 100µs 1.5 V 1.5V 0.6 A/µs 100µs 2V 90 dB 90 dB 84 dB 90 dB 85 dB 90 dB 75 dB 90 dB 75 dB 90 dB 90 dB 90 dB < 25 mOhm < 20 mOhm < 60 mOhm < 60 mOhm < 150 mOhm < 800 mOhm 15 Arms 200 Apeak 15 Arms 100 Apeak 10 Arms 70 Apeak 10 Arms 45 Apeak 5 Arms 25 Apeak 2.5 Arms 10 Apeak Insulation Input / output Creepage / clearance Input / case Output / case Safety MC Power supply stanadard Generic emission Generic immunity 3750 Vrms (1 min.) 8 mm 2500 Vrms 600 V DC EN 60950 / EN 6 1010 EN 61204-3, Emission: residential, light industrial environment (CISPR22-ClassB) Immunity: industrial environment EN 61000-6-3, residential, light industrial environment (EN55022B) EN 61000-6-2,industrial environment Operating temperature at full load - 20 to + 50 °C max. 95% RH, non condensing, up to 40 °C max. 75% RH, non condensing, up to 50 °C - 40 to + 85 °C Humidity Storage temperature Thermal protection Output shuts down in case of insufficient cooling MTBF 500 000 hrs Hold-Up Time 100% load Vin = 3x 380 V AC 50% load Vin = 3x 380 V AC Turn on delay After mains switch on Inrush current 6 ms 15 ms 300ms 5.8 A @ 400 V AC in put The power supply will continue to operate on one phase but at 90% of Vout(max) (a SM30-100D adjusted at 27 V will continue to deliver 27 V after phase loss) Phase loss Series Operation Max. total avoltage Master / Slave Operation Parallel Operation Max. total avoltage Master / Slave Operation Remote sensing Max. voltage drop per load lead OVP / OVL adjustment range Potentionmeters & Encoders Rront panel control with knobs Resolution Screwdriver adjustment Digital encoders Meters Scale Scale Accuracy LABORATORY POWER SUPPLIES 3 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY voltage current Doc. No. PBC9 Rev.C 28-4-11 SM 15-200D SM30-100D SM45-70 D SM70-45D SM120-25D SM300-10D 600 V yes 600 V yes 600 V yes 600 V yes 600 V yes 600 V yes no limit max. 4 units no limit max. 4 units no limit max. 4 units no limit max. 4 units no limit max. 4 units no limit max. 4 units 2V 2V 2V 2V 2V 2V 0 - 17 V 0 - 35 V 0 - 54 V 0 - 80 V 0 - 140 V 0 - 350 V standard 0.03 % standard 0.03 % standard 0.03 % standard 0.03 % standard 0.03 % standard 0.03 % option P001 option P002 option P001 option P002 option P001 option P002 option P001 option P002 option P001 option P002 option P001 option P002 3.5 digit 0 - 15.00 V 0 - 200 A 0.5% + 2 digit 3.5 digit 0 - 30.0 V 0 - 100.0 A 0.5% + 2 digit 3.5 digit 0 - 45.0 V 0 - 70.0 A 0.5% + 2 digit 3.5 digit 0 - 70.0 V 0 - 45.0 A 0.5% + 2 digit 3.5 digit 0 - 120.0 V 0 - 25.0 A 0.5% + 2 digit 3.5 digit 0 - 300 V 0 - 10.00 A 0.5% + 2 digit Powering Progress – www.powerbox.com.au 559 LABORATORY POWER SUPPLIES SM 3000 Series 560 3 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY Mounting Input terminals Input connections Output terminals Programming conector Cooling Audio noise level Enclosure Degree of protection Dimensions Behind front panel: h x w x d Front panel: h x w Weight M10 bolts Stacking of units allowed, air flow is from left to right screw termials for cable 1.5 - 4.0mm2 3 phase + earth (no neutral required) M10 bolts M10 bolts M8 bolts 7 mm bind post 15 pole D-connector at rear panel (FEMALE) 6 mm bind post Low noise blower, fan speed adapts to temperature of internal heatsink. ca. 50 dBA at full load and 25 °C ambient temperature ca. 60 dBA at full load and 50 °C ambient temperatur IP20 128.5 x 443 x 416 mm 128.5 x 483 mm (19", 3 U) (with option P099, feet are removed) 15kg Doc. No. PBC9 Rev.C 28-4-11 SM 3000 Series - Options Doc. No. PBC9 Rev.C 28-4-11 Powering Progress – www.powerbox.com.au LABORATORY POWER SUPPLIES 3 0 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY 561