SM 800 Series

SM 800 Series
FEATURES
•
•
•
•
•
•
•
•
•
•
Very low output ripple and spikes
Very stable output voltage or current
Excellent dynamic response to load changes
Master / Slave parallel and series operation with
equal current and voltage sharing
Designed for long life at full power
Protected against all over load and short circuit
conditions
V and I control with 10-turn potentiometers,
resolution 0.03 %. Optional with digital encoders
Silent blower, only runs when needed, variable
speed
0 - 5 V analog programmable on both voltage and
current
Ethernet, RS232 or IEEE488 programming options
SELECTION TABLE
SM 7.5-80
0 - 7.5 V
AUTORANGING
SM70-AR-24
SM 18-50
0 - 80 A
0 - 18 V
0 - 50 A
0 - 35 V
35 - 70 V
AUTORANGING
SM400-AR-4
0 - 24 A
0 - 12 A
0 - 200 V
200 - 400 V
0-4A
0-2A
LABORATORY POWER SUPPLIES
8 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
INPUT
AC single phase, 48 - 62 Hz
Power Derating vs input:
90 V : Pout max (W), Iin (A)
100 V : Pout max (W), Iin (A)
110 V : Pout max (W), Iin (A)
90 - 265 V
90 - 265 V
580, 8.5
600, 7.6
600, 6.9
90 - 265 V
Vo =16 V . Vo =18 V
725, 10 . 670, 9.2
800, 9.9 . 730, 8.9
800, 8.8 . 770, 8.4
740, 10
830, 10
840, 9
750, 10
800, 9.5
800, 8.5
600, 3.2
800, 4.1 . 900, 4.5
840, 4.2
800, 4
0.99, 0.96
0.99, 0.98
0.99, 0.98
0.99, 0.98
12.5 AT
14 W
18 W
12.5 AT
14 W
18 W
12.5 AT
14 W
20 W
35 V / 70 V
12.5 AT
14 W
26 W
200 V / 400 V
89 %
85 %
89 %
86 %
90 - 265 V
230 V : Pout max (W), Iin (A)
Power fac tor, 100%, 50% load
internal fuses
Standby input power (Vo=Io=0)
Standby input power (Vo=Vmax)
EFFICIENCY
AC 230 V input, full load
AC 115 V input, max. load
Doc. No. PBC9 Rev.C 28-4-11
82 %
80 %
87 %
83 %
Powering Progress – www.powerbox.com.au
547
LABORATORY POWER SUPPLIES
SM 800 Series
8 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
REGULATION
Load 0 - 100% CV
Line 120 - 265 V AC CV
(measured on sense block)
Load 0 - 100% CC
Line 120 - 265 V AC CC
(internal volt age sense)
Ripple + noise
rms (BW=300 kHz)
p-p (BW=50 MHz)
rms (BW=300 kHz)
p-p (BW=50 MHz)
CC-ripple at full load
CV
CV
CC
CC
Front panel connection
Load Regulation:
Load 0 - 100%
Ripple + noise
rms (BW=300 kHz)
p-p (BW=50 MHz)
CV
CV
CV
Temp. coeff., per °C
Stability
After 1 hr warm-up
During 8 hrs
0.2 mV
0.2 mV
0.5 mV
0.2 mV
2 mV
0.5 mV
10 mV
2 mV
4 mA
1 mA
3 mA
1 mA
1.5 mA
1 mA
0.5 mA
0.2 mA
2.5 mV
10 mV
25 mA
120 mA
2 mV
8 mV
5 mA
25 mA
3 mV
15 mV
3 / 1 mA
15 / 5 mA
15 mV
80 mV
0.8 / 0.5 mA
3 / 1.5 mA
Not available
Option 257
Option 258
Option 259
-
15 mV
3 mV
18 mV
40 mV
4 mV
20 mV
15 mV
18 mV
150 mV
CV
CC
35.10-6
60.10-6
CV
CC
6.10-5
9.10-5
tamb = 25 ± 1 °C, Vin = 230 V AC
(int. voltage sensing for CC-stab.)
ANALOG PROGRAMMING
Programming inputs
Input range
Accuracy
Offset
Temp. coeff. offset
Input impedance
Monitoring output
Output range
Accuracy
Offset
Temp. coeff. off set
Output impedance
Reference voltage
On prog. connector
+12 V out put
on prog. Connector
Remote shutdown
Interlock
Indicators (front panel)
Controls (front panel)
548
CC
0-5V
± 0.2%
- 0.1 ... +1.3 mV (on 5V)
10 V / °C
> 1 MOhm
0-5V
± 0.5%
0 ... +2.2 mV (on 5V)
50 V / °C
> 1 MOhm
0-5V
± 0.5%
- 1.1... 0 mV (on 5V)
60 V / °C
2 Ohm / max. 4 mA
0-5V
± 0.2%
- 1... 0 mV (on 5V)
3 V / °C
2 Ohm / max. 4 mA
5.114 V ± 15 mV (Ro = 2 Ohm, max. 4 mA)
20 ppm
Vref
TC
Vo
Imax
Ro
Relay Outputs
ACF
DCF
Status outputs
CC - status
LIM
OT
PSOL
ACF
DCF
CV
12 V ± 0.2 V
0.2 A
3 Ohm
AC - Fail
DC - Fail 1)
- status
- status
- status
- status
- status
CC - operation
CV- or CC-limit
Over Temperature
Power Sink Over load
AC - Fail
DC - Fail 2)
both NO and NC contact
both NO and NC contact
5 V = logic 1 (Ro = 500 Ohm)
5 V = logic 1 (Ro = 500 Ohm)
5 V = logic 1 (Ro = 500 Ohm)
5 V = logic 1 (Ro = 500 Ohm)
5 V = logic 1 (Ro = 500 Ohm)
5 V = logic 1 (Ro = 500 Ohm)
1)
2)
output voltage ± 5% beyond set point
output volt age ± 5% be yond set point
with + 5V, 1 mA or relay contact
Contact at rear panel
Voltage meter, Ampere meter, AC-Fail, Over Temperature, Power Sink Overlead, Remote-Shut Down,
Remote-CV, Remote-CC, Output On, CV-limit, CC-limit, CV and CC mode.
Mains on/off switch, CV and CC potmeter, CV and CC-limit-potmeter, Display Settings button,
Display-Limits button, Remote/Local button, Output On/Off button, Front panel Lock buttons.
Doc. No. PBC9 Rev.C 28-4-11
SM 800 Series
PROGRAMMING SPEED
STANDARD VERSION
SM 7.5-80
SM 18-50
SM 70-AR-24
SM 400-AR-4
Rise time (10 - 90%)
Output voltage step
Time, (100 % load)
Time, (10 % load)
0 g 7.5 V
6.5 ms
2.5 ms
0 g 16 V
12 ms
5 ms
0 g 35 V
6 ms
2.5 ms
0 g 200 V
4 ms
2 ms
0 g 400 V
8 ms
5 ms
0utput voltage step
Time, (100 % load)
Time, (10 % load)
Fall time (90 - 10%)
Output voltage step
Time, (100 % load)
Tme, (10 % load)
-
-
0 g 70 V
10 ms
7 ms
7.5 g 0 V
6.5 ms
62 ms
16 g 0 V
12 ms
120 ms
35 g 0 V
6 ms
60 ms
Output voltage step
Time, (100 % load)
Time, (10 % load)
-
-
70 g 0 V
25 ms
250 ms
PROGRAMMING SPEED
HIGH SPEED VERSION
SM 7.5-80
OPTION P250
SM 18-50
OPTION P251
SM 70-AR-24
OPTION P252
SM 400-AR-4
OPTION P253
Rise time (10 - 90%)
Output voltage step
Time, (100 % load)
Time, (10 % load)
0 g 7.5 V
0.2 ms
0.2 ms
0 g 16 V
0.22 ms
0.26 ms
0 g 35 V
0.24 ms
0.24ms
0 g 2005 V
0.4 ms
0.3ms
7.5 g 0V
0.2 ms
1 ms
16 g 0V
0.24 ms
1.95 ms
0 g 70 V
0.24 ms
0.24 ms
35 g 0V
0.27 ms
3 ms
0 g 400 V
0.82 ms
0.55 ms
200 g 0V
0.42 ms
4.6 ms
-
-
70 g 0 V
0.85 ms
9.5 ms
400 g 0 V
1.7 ms
20 ms
20 / 80 mV
400 / 120 mV
35 V / 24 A
25 / 90 mV
70 V / 12 A
30 / 110 mV
200 V / 4 A
35 / 200 mV
400 V / 2 A
30 / 160 mV
310µF
200µF
80µF
4µF
Output voltage step
Time, (100 % load)
Time, (10 % load)
Fall time (90 - 10%)
Output voltage step
Time, (100 % load)
Time, (10 % load)
Output voltage step
Time, (100 % load)
Time, (10 % load)
Ripple
@full load
@full load
(rms/pp)
(rms/pp)
Output capacitance
200 g 0 V
4 ms
42 ms
400 g 0 V
15 ms
155 ms
LABORATORY POWER SUPPLIES
8 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
Notes: All specifications regarding programming speed are typical and measured on a resistive load.
Recovery time
Recovery within
di/dt of load step
Output voltage
Time, @ 50 - 100% load step
Max.deviation
@ 230 VAC input voltage
Output impedance
CV, 0-1 kHz
CV, 1-100 kHz
Pulsating load
max.tolerable AC component
of load current
f > 1 kHz
f < 1 kHz
Insulation
Input / output
Creepage / clearance
Input / case
Output / case
Doc. No. PBC9 Rev.C 28-4-11
SM 7.5-80
SM 18-50
SM 70-AR-24
SM 400-AR-4
50 mV
1.25 A/µs
7V
100 µs
160 mV
60 mV
0.9 A/µs
15 V
100 µs
150 mV
35 V / 70 V
75 mV
0.4 / 0.2 A/µs
30 / 65 V
100 µs
250 / 200 mV
200 V / 400 V
1 / 0.5 V
0.1 / 0.05 A/µs
185 / 370 V
100 µs
2 / 1.5 V
< 1 m
< 30 m
< 2 m
< 30 m
< 7 m
< 30 m
<0.18m
<2
15 Arms
80 Apeak
15 Arms
50 Apeak
10 Arms
12 / 24 Apeak
0.4 Arms
2 / 4 Apeak
3750 Vrms (1 min.)
8 mm
2500 Vrms
600 V DC
Powering Progress – www.powerbox.com.au
549
LABORATORY POWER SUPPLIES
SM 800 Series
8 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
Safety
EMC
Power Supply Stanadard
Storage temperature
EN 60950 / EN 61010
EN 61204-3,Emission: residential, light industrial environment (CISPR22-ClassB)
Immunity: industrial environment
EN 61000-6-3, residential, light industrial environment (EN55022B)
EN 61000-6-2,industrial environment
- 20 to + 50 °C
derate output to 75% at 60 °C
max. 95% RH, non condensing, up to 40 °C
max. 75% RH, non condensing, up to 50 °C
- 40 to + 85 °C
Thermal protection
Output shuts down in case of insufficient cooling
MTBF
500 000 hrs
Generic Emission
Generic Immunity
Operating Temperature at full load
Humitidity
Hold-Up Time
Vout = 100%, Pout= <= 840 W
Iout=100%
Vout = 85%,
Vout = 100%, Iout= 50%
@230V AC input
Turn on Delay
after mains switch on
Inrush current
Series Operation
Max. total voltage
Master / Slave Operation
Parallel Operation
Max. total voltage
Master / Slave Operation
Remote Sensing
max. volt. drop per load lead
Limits Voltage
adjust range
Current
adjust range
Potentionmeters & Encoders
Front panel control with knobs resolution
Screwdriver adjustment
Digital encoders
Meters
Scale
Scale
A
600 ms @ 230 V AC, 900 ms @ 115 V AC
24 A@115 V AC, 22 A@230 V AC
600 V
yes
no limit
max. 4 units (including master)
2V
0 - 102%
0 - 102%
Standard
0.03 %
Option P001 (at front panel)
Option P236
voltage
current
ccuracy
read output
read limit setting
(d = digit)
SM 7.5-80
SM 18-50
SM 70-AR-24
SM 400-AR-4
3.5 digit
0 - 7.50 V
0 - 80.0 A
0.5% + 2 d
2% + 2 d
3.5 digit
0 - 18.00 V
0 - 50.0 A
0.5% + 2 d
2% + 2 d
3.5 digit
0 - 70.0 V
0 - 24.0 A
0.5% + 2 d
2% + 2 d
3.5 digit
0 - 400 V
0 - 4.00 A
0.5% + 2 d
2% + 2 d
Mounting
Stacking of units allowed, air flow is from rear to the sides.
Input connector
IEC320/C14, EN 60320/C14
Output terminals
M5 bolts
Programming connector
Cooling
Audio noise level
15 pole D-connector at rear panel (FEMALE)
Low noise blower, fan speed adapts to temperature of internal heatsink.
ca. 45 dBA at full load, 25 °C ambient temperature, 1 m distance
ca. 50 dBA at full load, 50 °C ambient temperature, 1 m distance
from rear sides.
Airflow
Enclosure
Degree of protection
Dimensions
Behind front panel: h x w x d
front panel: h x w
Weight
550
16ms
20ms
36ms
(time till DC-fall = 1)
IP20
86 x 221 x 406 mm (feet removed)
88.1 x 222 mm (1/2 19", 2 U)
5.4 kg
Doc. No. PBC9 Rev.C 28-4-11
SM 800 Series - Options
Doc. No. PBC9 Rev.C 28-4-11
Powering Progress – www.powerbox.com.au
LABORATORY POWER SUPPLIES
8 0 0 W A T T S P R O G R A M M A B L E D C S U P P LY
551