DC-AC INVERTER UNIT

DC-AC INVERTER UNIT
PS-M06D12S5-NJ4L-052(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Optimized for the AUO: B104SN02.
APPLICABLE LCD:
6.4 to 12 inches double lamp type
Lamp Voltage 540 Vrms
Lamp Current 6 mArms
Lamp Start Up Voltage 1.300 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
LxWxH
105 x 23 x 10mm
13 ± 0.5
PS-MXXDXX-NJX
29/01/2004
MADE IN
GERMANY
CN2
CN1-1
82 ± 0.3
CN1
5 ± 0.5
105 ± 0.5
(2)
15 ± 0.3
22,5 ± 0.5
DIMENSIONS :
0°C ~ +60°C
-20°C ~ +85°C
95 %RH max
CAUTION
HIGH VOLTAGE
CN2-1
Unit : mm
:20 (g) typ.
CN1-5
10.0MAX
CN2-4
3 Weight
2 - Ø2.5 ± 0.2
(for M2 screws)
2
(2)
1
High Voltage generation area 60mm
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
GND
CN 1-2
CN 1-3 Ext. PWM
N.C.
CN 1-4
CN 1-5
Vrm t
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM03(4.0)B-BHS
Output side CN2:
Pin No.
Symbols
Vhigh
CN 2-1+2
N.C.
CN 2-3
Vlow
CN 2-4
Ratings
12 Vdc
0 / 5 Vdc (H activ)
Note
t=1m m
JST or equal
JST or equal
Ratings
540 Vrm s (6 m Arm s )
0 Vdc
0 / 5 Vdc (H activ)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
c Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.1, 14th March 2007
DC-AC INVERTER UNIT
PS-M06D12S5-NJ4L-052(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Conditions
Vrmt
Vin (V)
Tu (°C)
(V)
Iout1+2
5±1.2 5±0.25 0 ~ +60
Output Current
Iout1+2
5±0.6 5±0.25 0 ~ +60
Output Current
Iin
5±1.2 5±0.25 0 ~ +60
Input Current
F
5±1.2 5±0.25 0 ~ +60
Frequency
4.7
5±0.25 0 ~ +60
Open Circuit Voltage Vopen
Ext PWM
0/5
5±0.25 0 ~ +60
Dimming Function
Parameters
Note 1 :
Symbols
Specification
Min.
Typ.
Max.
5.5
5.0
TBD
1.200
5.5
6.0
6.0
0.7
50
1.300
6.0
6.5
7.0
1.2
TBD
6.5
Unit
Note
m Arm s
m Arm s
Adc
kHz
Vrm s
m Arm s
Dut y Circle variable
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
External PWM-Dimming / Remote ON / OFF Detailed Circuit Diagram :
Note 2:
Remote On/Off has always priority. If you would like to use external PWM-dimming
Remote On/Off must be N.C.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
c Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)