DC-AC INVERTER UNIT - Power

DC-AC INVERTER UNIT
PS-M04D12S3-NJ1L-042(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Optimized for Kyocera: TCG075VG2A
APPLICABLE LCD:
6.4 to 12 inches double lamp type
Lamp Voltage 440 Vrms
Lamp Current 4.0 mArms
Lamp Start Up Voltage min. 1.250 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Ext. PWM-Dimming Function or Remote ON/OFF
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
LxWxH
123 x 23 x 10mm
122,5 ± 0.5
30,5 ± 0.5
82 ± 0.3
(2)
CN2
1
PS-M06D05-NJ1L
29/01/2004
MADE IN
GERMANY
CN1
15 ± 0.3
22,5 ± 0.5
5 ± 0.5
DIMENSIONS :
-10°C ~ +70°C
-20°C ~ +85°C
95 %RH max
CAUTION
HIGH VOLTAGE
CN3
1
1
10.0MAX
3
Unit : mm
Weight :20 (g) typ.
2 - Ø2.5 ± 0.2
2
1
High Voltage generation area 60mm
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 + CN3
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
GND
CN 1-2
CN 1-3 Ext. PWM
N.C.
CN 1-4
CN 1-5
Vrm t
Qty.
1
1
2
Ratings
12 Vdc
0 ~ 5 Vdc (L activ)
0 / 5 Vdc (H activ)
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM02(8.0)B-BHS-1-TB
Output side CN2:
Pin No.
Symbols
Vhigh
CN 2-1
Vlow
CN 2-2
Output side CN3:
Pin No.
Symbols
Vhigh
CN 3-1
Vlow
CN 3-2
Note
t=1.6m m
JST or equal
JST or equal
Ratings
440 Vrm s (4.0 m Arm s )
0Vdc
Ratings
440 Vrm s (4.0 m Arm s )
0Vdc
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.3.2, 14th March 2007
DC-AC INVERTER UNIT
PS-M04D12S3-NJ1L-042(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout1+2
Iout1+2
Iin
F
Vopen
Note 1 :
Note 2:
Conditions
Vrmt
Vin (V)
Tu (°C)
(V)
12±0.5 5±0.25 0 ~ +60
12±1 5±0.25 0 ~ +60
12±1 5±0.25 0 ~ +60
12±1 5±0.25 0 ~ +60
12±1 5±0.25 0 ~ +60
Specification
Min.
Typ.
Max.
3.5
3.0
50
1.250
4.0
4.0
1.6
60
-
4.5
5.0
2.5
70
-
Unit
Note
m Arm s
m Arm s
Adc
kHz
Vrm s
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
You can use external PWM or Remote ON / OFF. Not both together.
In case of both together Remote ON / OFF has priority and ext. PWM is out of function.
If using ext. PWM let CN1-5 open.
TEST CIRCUIT :
F
Vin
12 V
A
Iin
1000:1
PROBE
F
CN1-1
SW 1
Vopen V
~
Operation of unit
a
Operation
b
Non operation
SW3
V
CN2-1
CN1-2
CN1-3
A
~
T1
Ext. PWM*
0~5V
NC
CL1
RL1
CN2-2
SW4
Iout1
SW5
CN1-4
CN3-1
Vrmt
2.5 Vdc ~ Vin
V
b
CL2
RL2
a
SW1
CN1-5
CN3-2
SW6
A
~
Iout2
*) Only active when Vrmt is 0 Vdc or floating
External PWM-Dimming / Remote ON / OFF Detailed Circuit Diagram :
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)