DC-AC INVERTER UNIT PS-M06D12S6-NJ1L(S) (6,5 W DUAL OUTPUTS) (PRELIMINARY INFORMATION) DESCRIPTION : This low profile DC to AC Inverter is developed for dual lamps. Please contact us for confirmation regarding compatibility with your display. APPLICABLE LCD: 6.4 to 12 inches double lamp type Lamp Voltage 500 Vrms Lamp Current 6.5 mArms Lamp Start Up Voltage min. 1.500 Vrms (Vin : 12 Vdc) FEATURES : Remote ON/OFF Ext. PWM-Dimming Function RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity LxWxH 123 x 23 x 10mm 122,5 ± 0.5 30,5 ± 0.5 82 ± 0.3 (2) CN2 1 PS-M06D05-NJ1L 29/01/2004 MADE IN GERMANY CN1 15 ± 0.3 22,5 ± 0.5 5 ± 0.5 DIMENSIONS : -10°C ~ +60°C -20°C ~ +85°C 95 %RH max CN3 1 CAUTION HIGH VOLTAGE 1 10.0MAX 3 Unit : mm Weight :20 (g) typ. 2 - Ø2.5 ± 0.2 2 1 High Voltage generation area 60mm Note: Please use plastic screw in case of a non-insulating mounting base! Components No. 1 2 Part Description PCB Connector CN1 Qty. 1 1 Material UL94V-0 (FR-4 or CEM-3) S5B-PH-SM3 Note t=1.6m m JST or equal 3 Connector CN2 + CN3 2 SM02(8.0)B-BHS-1-TB JST or equal Input side CN1: Pin No. CN 1-1 CN 1-2 CN 1-3 CN 1-4 Symbols Vin GND Ext. PWM N.C. CN 1-5 Vrm t Output side CN2: Ratings 12 Vdc Pin No. CN 2-1 Symbols Vhigh Ratings 500 Vrms (6.5 mArms) CN 2-2 Vlow 0Vdc 0 ~ 5 Vdc (L activ) Output side CN3: 0 / 5 Vdc (H activ) Pin No. CN 3-1 Symbols Vhigh Ratings 500 Vrms (6.5 mArms) CN 3-2 Vlow 0Vdc Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (1) Version 1.0.3, 12th February 2010 DC-AC INVERTER UNIT PS-M06D12S6-NJ1L(S) (6,5 W DUAL OUTPUTS) (PRELIMINARY INFORMATION) ELECTRICAL CHARACTERISTICS : Parameters Output Current Output Current Input Current Frequency Open Circuit Voltage Note 1 : Note 2 : Note 3: Note 4: Conditions Vrmt Tu (°C) Vin (V) (V) Iout1+2 12±0.12 5±0.25 -10 ~ +60 Iout1+2 12±1.2 5±0.25 -10 ~ +60 Iin 12±1.2 5±0.25 -10 ~ +60 F 12±1.2 5±0.25 -10 ~ +60 Vopen 11.4 5±0.25 -10 ~ +60 Specification Symbols Min. Typ. Max. 6.0 5.5 45 1.450 6.5 6.5 0.7 55 1.500 7.0 7.5 1.2 65 - Unit Note mArms mArms Adc kHz Vrms Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming (CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected. The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please request. The optimum is 250 Hz. Here you will normally not get a interference to the vertical sync. frequency. Please contact us for 24V input voltage. TEST CIRCUIT : Vin 12 V F A Iin 1000:1 PROBE F CN1-1 SW 1 Vopen V ~ SW3 V Operation of unit a Operation b Non operation CN2-1 CN1-2 CN1-3 A ~ T1 Ext. PWM* 0~5V NC CL1 RL1 CN2-2 SW4 Iout1 SW5 CN1-4 CN3-1 Vrmt 2.5 Vdc ~ Vin V b CL2 RL2 a SW1 CN1-5 CN3-2 SW6 A ~ Iout2 *) Only active when Vrmt is 0 Vdc or floating External PWM-Dimming / Remote ON / OFF Detailed Circuit Diagram : Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (2) Version 1.0.3, 12th February 2010