LED-CONVERTER UNIT PS-LD0602-x-yyy(S) (3 W) (PRELIMINARY INFORMATION) DESCRIPTION : This low profile LED-Converter is developed for max. 6 LED-lines APPLICABLE: 1~6 LED lines (Serial Mode) Pout max. 0,9 Watt per line, total max. 3 Watt LED Voltage max. 35V Lamp Current max. 35 mAdc per line FEATURES : Connector style Internal Open LED Detection for every Line Analog or ext. PWM Dimming 1000:1 dimming ratio with external PWM Remote ON / OFF Wide Input Voltage Range RoHS compliant (S) TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxWxH Pin-terminal style -20°C ~ +70°C -20°C ~ +85°C 95 %RH max 64 x 32 x 6.5 mm Weight :5 (g) typ. Pin terminal length may differ Components No. 1 2 Part Description PCB Connector CN1 Qty. 1 1 Material UL94V-0 (FR-4 or CEM-3) 53261-0890 Note t=1.0mm Molex 3 Connector CN3 1 53261-0790 Molex Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (1) Version 1.2.3, 14th May 2014 LED-CONVERTER UNIT PS-LD0602-x-yyy(S) (3 W) (PRELIMINARY INFORMATION) Input side CN1/CN2: Pin No. CN 1-1 CN 1-2 CN 1-3 CN 1-4 CN 1-5 CN 1-6 CN 1-7 Output side CN3 / CN4 Symbols Ratings Vin 4.75 ~ 13.2 Vdc Vin 4.75 ~ 13.2 Vdc Vrm t 0 ~ 0.8 = OFF / 2.5 ~ Vin = ON Ext. PWM 0 ~ 0.5 = LOW / 2.5 ~ 5 = HIGH Vbr 0.0 ~ 5.0 (5V=low brightnes s ) GND GND GND CN 1-8 Pin No. CN3 / 4-1 CN3 / 4-2 CN3 / 4-3 CN3 / 4-4 CN3 / 4-5 CN3 / 4-6 Symbols RTN1 (-) RTN2 (-) RTN3 (-) RTN4 (-) RTN5 (-) RTN6 (-) Ratings LED LINE 1 RETURN LED LINE 2 RETURN LED LINE 3 RETURN LED LINE 4 RETURN LED LINE 5 RETURN LED LINE 6 RETURN CN3 / 4-7 Vhigh (+) max 30Vdc (max.30mAdc) - Output Current Select Control Jumper JP 1 Break JP 2 JP 3 JP 4 Output Current JP 5 Break Break Break Example: +1 mA 10mA (Output Current Min.) + 1mA (JP1) = 11mA +2 mA 10mA (Output Current Min.) + 8mA (JP4) = 18mA +4 mA JP1 ~ JP5 OPEN = 30mA +8 mA Break +5 mA For more information, please visit our web-site. ELECTRICAL CHARACTERISTICS : Conditions Parameters Symbols Output Current Output Current Input Current Open Load Shutdown PWM Frequency Output Power Output Power Output Power Output Power Iout Imin Iin Vbias f(PWM) Pout Pout Pout Pout Specification Vin (V) Vbr (V) Tu (°C) Min. Typ. Max. 4.75 ~ 13.2 4.75 ~ 13.2 4.75 ~ 13.2 4.75 ~ 13.2 4.75 ~ 13.2 4.75 ~ 13.2 4.75 ~ 13.2 4.75 ~ 13.2 4.75 ~ 13.2 0 5 0 0 0 0 0 0 0 -20~+70 -20~+70 -20~+70 -20~+70 -20~+70 -20~+70 -20~+70 -20~+50 -20~+70 8 0.06 150 TBD TBD TBD TBD 10 10 35 3 1.9 0.9 0.6 12 0.3 300 TBD TBD TBD TBD DERATING: OUTPUT WATT DC 5V Input Unit Note mAdc % Adc Vdc Hz Watt Watt Watt Watt Duty 100%, max current dut y cycle Tu: -20~+50degC Tu: -20~+70degC For one line For one line DC 12V Input 3,4 3,2 3 2,8 2,6 2,4 2,2 2 1,8 1,6 1,4 1,2 1 50 55 60 65 70 75 80 AMBIENT TEMP. Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (2) Version 1.2.3, 14th May 2014 LED-CONVERTER UNIT PS-LD0602-x-yyy(S) (3 W) (PRELIMINARY INFORMATION) TEST CIRCUIT : Connect Vbr to Ground while using ext. PWM dimming. Do not connect ext. PWM dimming while using Vbr. Note 1 : Note 2 : Note 3 : Note 4: Do not use analog dimming and external PWM dimming at the same time. Pin Terminal Style converters are mounted with Molex connectors. External PWM-signal is LOW active. Do not use output 1 when you need to connect only 5 or less outputs. Examples: Connect pin 2+3+4+5+6 when only 5 are needed. Note5 : In case of not needing to connect all outputs please ask factory which pins to connect according to your needs. ORDER KEY : PS-LD0602-x-yyy When ordering this converter please give the following keys: -x is to be replaced by: -1 for connectors -2 for Pin-Terminal A pre-configured order can be placed from 300 pieces upwards -yyy is to be replaced by: Three digit value for required output current per LED line (from 010 to 030 including) Attention: * 10 mA output current per LED line will be set as default when no specific current is mentioned * Incorrect LED currents can reduce the lifetime of the backlight or even destroy it * Orders of pre-configured converters can’t be cancelled Examples: PS-LD0602-1-015 (S) 15 mA output current PCB with connectors PS-LD0602-2-025 (S) 25 mA output current PCB with Pin-Terminal CABLES : for input: 500 mm, stripped and tinned ends, order key <input cable #13> for output: 500 mm, stripped and tinned ends, order key <input cable #4> Power Systems – The Power Solution Web: Email: www.Power-Systems.de [email protected] All specifications are subject to change without notice. Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Page (3) Version 1.2.3, 14th May 2014